Experimental results and interpretation of BAC data
Specp. 5
Sensitivity performance data for the Femto Pulse system
p. 6
Summary of findings and recommendations
p. 2table, 6 rows
p. 4table, 4 rows
p. 5table, 5 rows
Table 1. Comparison of PFGE and the Agilent Femto Pulse system.
Attribute
PFGE*
Agilent Femto Pulse system
Samples per Run
1 to 14
1 to 11
Sample Amount
Nanograms
Picograms
Separation Time
10 to 24 hours
3 hours
Total Time (Inc. Gel Prep., Separation, and Staining)
12 to 26 hours
3 hours
Size Range
Up to 10 Mb
75 bp to 165 kb
Result Format
Agarose gel image; requires manual annotation and documentation
Digital gel image and electropherogram; automated sizing analysis
*Attributes based on Bio-Rad Chef Mapper XA system
Table 2. Comparison of the expected BAC and vector sizes reported by the Agilent Femto Pulse system with the Agilent 165 kb BAC kit. (Note: the largest fragment splits into two partially resolved peaks. For sizing, the peaks were analyzed together using the smear analysis function in Agilent ProSize data analysis software.)
BAC Expected Size (bp)
BAC D1 Femto Pulse Size (bp)
Vector Expected Size (bp)
Vector D2 Femto Pulse Size (bp)
98,186
93,008
101,249
93,968
32,257
31,086
32,257
30,390
6,165
7,307
2,655
2,692
2,655
3,125
Table 3. Comparison of the expected BAC and vector sizes to the sizes reported by the Agilent Femto Pulse with the Agilent 165 kb BAC kit.
BAC Expected Size (bp)
BAC B5 Femto Pulse Size (bp) (Pass)
Vector (B6, B7) Expected Size (bp)
Vector B6 Femto Pulse Size (bp) (Fail)
Vector B7 Femto Pulse Size (bp) (Fail)
47,537
47,653
51,534
45,622
46,186
11,472
12,194
11,472
11,633
11,531
457
455
6,715
4,876
325
310
1,695
457
453
449
325
310
308
Engineering Facts
12 facts · every claim linked to a page
Selection
The Femto Pulse with the 165 kb BAC kit resolves fragments up to 165 kb, so it can replace PFGE for BAC digest sizing within that range.
Defines the upper sizing limit that determines whether this instrument fits the BAC fragment sizes in the workflow.
Source
“such as digested BAC samples up to
165 kb in less than 3 hours”
Performance
Separation takes about 3 hours versus 10 to 24 hours for PFGE, removing the overnight bottleneck.
Run time drives throughput planning and lab scheduling when choosing between PFGE and capillary electrophoresis.
Source
“Separation Time
10 to 24 hours
3 hours”
Selection
The system needs only picogram-level sample input versus nanograms for PFGE, which matters when BAC material is scarce.
Sample consumption is a key selection criterion for precious BAC and vector digests.
Source
“Sample Amount
Nanograms
Picograms”
Installation
The instrument runs up to 11 samples per run, so batch capacity must be planned accordingly.
Throughput per run determines how many digests can be batched and how the lab schedules QC.
Source
“Samples per Run
1 to 14
1 to 11”
Operation
Salts in the digest must be diluted out per Appendix A before loading, otherwise mobility and sizing may be affected.
Sample matrix handling is a mandatory prep step to obtain reliable sizing results.
Source
“Salts present in the samples
were diluted out following the additional
sample preparation instructions in
Appendix A of the quick guide”
Operation
The digestion reaction is diluted 10X in Dilution Buffer 0.25x TE, then 2 µL is mixed with 18 µL gDNA Diluent Marker using a wide bore pipette.
Exact dilution and pipetting steps must be followed to avoid sizing errors and sample loss.
Source
“the digestion reaction was diluted 10X
using Dilution Buffer 0.25x TE”
Operation
The 165 kb BAC Ladder must be prepared for a 10X sample predilution and run in parallel with samples to compensate for matrix effects on mobility.
Correct ladder preparation is required for accurate, matrix-matched sizing.
Source
“the 165 kb BAC
Ladder working solution was prepared
according to the specifications for a 10X
sample predilution”
Performance
The largest fragment can split into two partially resolved peaks, which must be analyzed together using smear analysis in ProSize.
Data analysis settings affect reported sizes and must be configured for correct QC calls.
Source
“the largest fragment splits into two partially resolved peaks.
For sizing, the peaks were analyzed together using the smear analysis function”
Performance
Small fragments below 500 bp are lost on PFGE but detected by the Femto Pulse, giving higher sensitivity in the low size range.
Detection of small fragments is decisive for confirming recombination and avoiding false passes.
Source
“The two fragments with
expected sizes below 500 bp cannot be
visualized on the PFGE gel image”
Operation
PFGE comparison runs used a 1% PFGE-grade agarose gel and a 10.5-hour method for 2 to 200 kb fragments.
Defines the reference PFGE method parameters needed for a valid side-by-side comparison.
Source
“a method to allow for
separation of fragments between 2 to
200 kb for 10.5 hours”
Maintenance
PFGE gels require post-staining with 10X Gel Red and UV imaging at 365 nm, adding staining and destaining time to the workflow.
Extra staining and imaging steps explain the longer total time and consumable burden of PFGE.
Source
“The agarose gel was
post-stained with a 10X Gel Red solution”
Cumplimiento
The system is for research use only and not for diagnostic procedures, which constrains its deployment.
Regulatory labeling determines whether the instrument can be used in clinical or diagnostic settings.
Source
“For Research Use Only. Not for use in diagnostic procedures.”