Purify Your Way: Flexible Column Solutions

Contenido

  1. Overview pp. 1-4
    Introduction to flexible column solutions and purification needs
  2. Spec p. 5
    Highest bed stability performance data and comparison table
  3. Config. pp. 6-7
    Two compression modes for versatility and DAC traditional approach
  4. Procedure pp. 8-9
    Safe intuitive packing stations and flexible column packing locations
  5. Ordering pp. 10-11
    Sample purification flexibility and full portfolio brochure table
  6. Services p. 12
    Reliable efficient innovation for best results
  7. p. 5 table, 3 rows

Figure 4. A packing study using a 2 in id Load & Lock Column demonstrates excellent reproducibility.

Packing #Nth/meterAsRT [min]
140,6061.2715.18
241,5221.2215.28
341,1641.3015.26

Engineering Facts

12 facts · every claim linked to a page
Selection

The columns are offered in inside diameters from 1 to 3 inches (27 to 75 mm), which defines the scale range an engineer can specify.

Determines whether the column matches the required preparative scale and flow range.

Source
“Agilent Load & Lock Columns are available with inside diameters from 1 to 3 inches (27 to 75 mm)”
Selection

The columns uniquely support both DAC and SAC compression modes, so one column type can serve different sorbent and process requirements.

Allows selecting a single column platform that covers both dynamic and static compression needs.

Source
“Agilent Load & Lock columns are the only commercially available columns that allow you to use both DAC and SAC.”
Selection

SAC should be chosen for particles of 10 µm or larger, irregular shapes, or fragile sorbents such as 300 Å and polymeric media.

Prevents crushing fragile sorbents and preserves separation integrity during packing.

Source
“Use SAC for sorbents with particle sizes of 10 μm or larger, for irregular-shaped particles, or for easily damaged or sensitive sorbents”
Selection

DAC is the traditional mode suited to spherical 8–15 µm sorbents that can withstand substantial hydraulic forces.

Guides compression-mode choice based on sorbent particle type and strength.

Source
“Sorbents with spherical particles in the 8 to 15 μm range are typically used, which can withstand the substantial hydraulic forces applied.”
Installation

The mobile packing station needs only compressed air and no electrical power, so it can be placed in hazardous or solvent-exposed areas.

Simplifies site requirements and permits safe placement in hazardous environments.

Source
“Requiring only compressed air at a pressure of 6 bar (90 psi), the Mobile Packing Stations do not need electrical power”
Installation

One packing station serves 1, 2, and 3 inch id columns, and columns can be locked and undocked for deployment elsewhere.

Reduces total cost of ownership and enables a central packing zone separate from purification areas.

Source
“you need only one packing station for 1, 2, and 3 in id columns”
Operation

The slurry or rapid pack method uses 60% or less of the column tube length and requires no reservoir.

Defines the practical packing procedure and bed-length planning for operators.

Source
“This technique utilizes 60% or less of the available column tube length. No reservoir is required for packing”
Operation

Column temperature can be held constant up to 60 °C via the water jacket for reproducible results with thermally labile samples.

Sets the operating temperature limit and the need for a circulating water source.

Source
“Constant column temperatures up to 60 °C can be maintained, delivering excellent column-to-column reproducibility.”
Installation

The stainless steel water jackets are welded directly to the column and must be connected to a hot- or cold-water source such as a circulating bath.

Requires plumbing for a water source at the installation site for temperature control.

Source
“Load & Lock Columns are equipped with stainless steel water jackets welded directly to the column.”
Performance

The proprietary distribution plates increase sample loading by about 20%, improving throughput and reducing production costs.

Quantifies the productivity benefit that justifies the column choice.

Source
“the resulting 20% increase in sample loading allows you to produce more purified material per unit time”
Performance

A packing study on a 2 inch id column showed plate counts around 40,000–41,500 N/m with consistent retention times across three packings.

Provides evidence of packing reproducibility relevant to method validation and scale-up.

Source
“A packing study using a 2 in id Load & Lock Column demonstrates excellent reproducibility.”
Operation

The air-driven constant-pressure hydraulic pump can be operated in either dynamic or static axial compression mode.

Confirms the station supports both compression modes required by the process.

Source
“An air-driven, constant pressure hydraulic pump controls the packing stations’ hydraulic cylinder, which can be operated in either dynamic or static axial compression mode.”