Clinical NGS Sample QC Solution

Contenido

  1. Overview pp. 1-3
    Introduces the clinical NGS sample QC solution and its purpose
  2. Overview pp. 4-5
    Explains scaling sample QC throughput and reliable performance
  3. Quality pp. 6-7
    Describes dependable QC results and data integrity protection
  4. Quality p. 8
    Highlights sustainable, transparent, and verified product attributes

Engineering Facts

14 facts · every claim linked to a page
Selection

The 4200 model is the choice for labs needing scalable throughput from 1 to 96 samples with flexible loading.

Determines whether the instrument can cover both small batches and full 96-well plate runs without a second system.

Source
“Complete scalability: Analyze any sample number from 1 to 96 samples.”
Selection

The 4200 accepts either two 8-tube strips or a 96-well plate, so labware format must be decided at selection.

Loading format drives consumables, workflow design, and compatibility with existing sample handling.

Source
“Sample loading from two 8-tube strips or a 96-well plate.”
Selection

The 4150 is limited to 16 samples per run, so higher-volume labs must pick the 4200.

Defines the maximum batch size and prevents undersizing the instrument for expected workload.

Source
“Sample loading from two 8-tube strips. Complete scalability: Analyze any sample number from 1 to 16 samples.”
Installation

The 4150 has a compact footprint suited to space-constrained labs, which matters for bench planning.

Bench space availability is a hard constraint during site preparation and instrument placement.

Source
“Small footprint saves valuable bench space in your laboratory”
Performance

The 4200 completes 96 samples in under 90 minutes, setting the throughput benchmark for planning runs.

Run time per plate determines daily capacity and scheduling of downstream NGS workflows.

Source
“Reliable, reproducible results in less than 90 minutes for 96 samples”
Performance

The 4150 completes 16 samples in under 20 minutes, giving fast turnaround for small batches.

Turnaround time per batch affects how quickly samples can be released to downstream assays.

Source
“Reliable, reproducible results in less than 20 minutes for 16 samples”
Operation

The system needs only 2 µL or less of sample, preserving limited patient material.

Low input volume is critical when clinical samples are scarce or must be conserved for other assays.

Source
“while preserving valuable patient material with minimal sample input (≤ 2 µL).”
Operation

Per-sample time is 1–2 minutes, which should be used for realistic throughput and cost-per-sample estimates.

Supports calculation of effective throughput and cost-per-sample for the lab's workload.

Source
“fast, reliable results in just 1–2 minutes per sample”
Cumplimiento

The software supports IVDR and 21 CFR Part 11–aligned frameworks, which is decisive for regulated labs.

Regulatory alignment must be confirmed before purchase in clinical and regulated environments.

Source
“supporting IVDR, and 21 CFR Part 11–aligned frameworks”
Cumplimiento

Role-based user management and secure login are built in to prevent unauthorized access and data manipulation.

Access control features must be configured and validated during installation for data integrity.

Source
“Prevents unauthorized access and reduces risk of data manipulation.”
Cumplimiento

Complete audit trails and system logs provide traceability from sample to report for inspection readiness.

Audit trail capability is required for inspection readiness and must be verified during qualification.

Source
“Complete audit trails and system logs”
Cumplimiento

Integrated electronic signatures and configurable approval steps support compliant result release.

eSignature support affects workflow design and approval routing in regulated operations.

Source
“Integrated electronic signatures”
Maintenance

Routine maintenance and qualification are needed to safeguard data accuracy and traceability and avoid downtime.

Planned service and qualification must be budgeted and scheduled to keep the system compliant and running.

Source
“Routine maintenance and qualification safeguard data accuracy and traceability”
Selection

The systems are CE-IVD labeled for in vitro diagnostic use, which is a prerequisite for clinical deployment.

IVD labeling status determines eligibility for diagnostic use in regulated laboratories.

Source
“combine a CE-IVD-labeled, compact benchtop instrument with Agilent TapeStationDx software”