Introduces the Agilent ICP workflow automation system and its benefits
Overviewpp. 3-5
Explains how automation improves ICP workflow efficiency
Config.p. 6
Describes the integrated all-Agilent ICP automation system configuration
Config.p. 7
Details the Agilent Advanced Dilution System component
Procedurepp. 8-14
Walks through the steps of the Agilent ICP workflow
Config.p. 15
Describes the switching valve component and its role
Config.p. 16
Describes the autosampler component and its features
Servicesp. 17
Lists Agilent services, spares, and consumables
Servicesp. 18
Describes Agilent CrossLab service offerings and outcomes
p. 3table, 7 rows
What are the most time-consuming manual tasks in the lab?
Rank
Task
Percentage
1
Preparing digestions or acidifying samples
80%
2
Preparing calibration standards
69%
3
Remeasuring samples due to data quality issues
60%
4
Diluting samples before ICP analysis
60%
5
Diluting and remeasuring samples after ICP analysis
55%
6
Screening samples before ICP analysis
40%
7
Loading samples for analysis
37%
* Results from an online poll of over 120 laboratories, conducted in 2024
Engineering Facts
13 facts · every claim linked to a page
Selection
The autodilutor is designed and manufactured by Agilent and integrates with Agilent ICP-OES and ICP-MS instruments, so it should be selected only for those platforms.
Confirms platform compatibility before purchase and avoids integration work with non-Agilent ICPs.
Source
“Designed and manufactured by Agilent, the Advanced Dilution System (ADS 2) integrates with Agilent ICP-OES and ICP-MS instruments.”
Performance
Samples that do not require dilution bypass the autodilutor, so analysis time is almost unchanged for undiluted samples.
Important for throughput planning: adding the autodilutor does not penalize routine undiluted samples.
Source
“samples that don’t require dilution bypass the autodilutor, so there’s almost no increase in analysis time.”
Operation
The autodilutor can prepare dilutions up to 400-fold and can prepare standards automatically from nominated stock solutions and calibration ranges.
Defines the dilution range the lab can automate and whether it covers expected over-range samples.
Source
“The autodilutor can prepare up to 400 fold dilutions.”
Operation
Targeted dilution lists allow dilution only for over-range elements, avoiding unnecessary dilutions that consume sample and reduce throughput.
Useful for high-matrix samples such as brine where blanket dilution would waste sample and time.
Source
“you can choose to dilute samples that are over-range only for a particular element, avoiding unnecessary dilutions that can impact sample consumption and throughput.”
Cumplimiento
The results summary report automatically selects optimal results per element and retains all data for integrity, with export to LIMS.
Supports data integrity and LIMS integration requirements during method setup and validation.
Source
“Export this data set, or all data, to LIMS. All data is retained for integrity purposes.”
Installation
The autodilutor has a small footprint for close-coupling with the ICP and autosampler to minimize tubing lengths and maximize throughput.
Affects bench layout and tubing routing during installation.
Source
“the autodilutor has a small footprint for close-coupling with your ICP and autosampler to minimize tubing lengths and maximize sample throughput.”
Installation
All tubing is pre-plumbed, color-coded, and labeled to simplify installation and maintenance.
Reduces installation time and risk of misconnection during setup.
Source
“All tubing is pre-plumbed, color-coded and labeled for easy installation and maintenance.”
Maintenance
Early Maintenance Feedback uses traffic-light color coding to show which maintenance activities are immediate and which can wait, monitoring instrument, autodilutor, and switching valve.
Helps plan maintenance schedules and avoid unplanned downtime.
Source
“Traffic light color-coding of the counters visually shows which maintenance activities should be done immediately, and which can wait.”
Maintenance
The instrument self-test includes autodilutor testing and identifies incorrectly connected tubing.
Provides a first-line troubleshooting check after installation or tubing changes.
Source
“The instrument self test function includes testing of the autodilutor, identifying any incorrectly connected tubing.”
Performance
The switching valve doubles sample throughput and reduces cost per sample and turnaround time by rinsing the sample introduction system during measurement.
Key throughput justification when specifying a switching valve.
Source
“The Agilent Advanced Valve System (AVS) is a switching valve that doubles sample throughput, reduces cost per sample and results turnaround time.”
Maintenance
The switching valve reduces maintenance frequency and extends consumable lifetime by limiting exposure of torches, nebulizers, pump tubes, and ICP-MS cones to aggressive chemicals.
Affects long-term consumable cost and maintenance planning.
Source
“The switching valve also reduces maintenance frequency and increases the life-time of consumables”
Selection
The SPS 4 handles up to 360 samples and the SPS 6 up to 540 samples, so rack capacity should be matched to expected sample load.
Determines which autosampler model fits the lab's throughput and bench space.
Source
“The SPS 6 is a six sample rack autosampler with 50% more capacity than the SPS 4, offering up to 540 samples”
Safety
An integrated cover protects samples from contamination and protects the lab from corrosive sample vapors, and a dual port-wash reservoir allows multiple rinse solutions.
Relevant for lab safety and cross-contamination control during installation and operation.
Source
“An integrated cover protects samples from contamination and protects your lab from corrosive sample vapors.”