Selection
Model choice is driven by daily sample throughput, so the 5200 suits 12-96 samples one to three times per day.
Lets you match instrument model to actual lab workload before purchase.
Source
“Medium throughput system for labs running 12-96 samples one to three times per day.”
Selection
The 5400 is intended for robotic automation exceeding two 96-well plates per day.
Determines whether you need automation integration and the ultrahigh-throughput model.
Source
“Ultrahigh-throughput system for robotic automation running more than two 96-well plates per day.”
Operation
Two onboard gels allow switching between different applications without manual gel exchange.
Affects workflow design and how many assay types can run back-to-back unattended.
Source
“Two gel capacity enables seamless switching between applications”
Maintenance
Room-temperature stable reagents and no daily array handling reduce hands-on maintenance time.
Informs reagent storage requirements and daily labor planning.
Source
“No daily array handling and room-temperature stable reagents minimize hands on time”
Performance
Separation resolution can be as good as 3 bp, which matters for closely sized fragments.
Sets expectations for resolving near-identical fragment sizes in QC.
Source
“See clear results with separation resolution as good as 3 bp”
Selection
Arrays come in 12, 48, or 96 capillaries to match throughput needs.
Array choice is a key purchasing and configuration decision.
Source
“Choose the array that best fits your throughput needs, 12, 48, or 96 capillaries.”
Operation
Array length trades separation speed against resolution, so method must match the application.
Guides selection of capillary array length for the required resolution.
Source
“Shorter capillaries offer faster separation times but reduce separation resolution.”
Maintenance
The capillary array can be stored on the instrument with automated cleaning and conditioning.
Reduces array handling and informs installation/storage planning.
Source
“Durable design and construction allow the capillary array to be stored on the instrument.”
Operation
Each well needs only 2 µL of sample with a single dilution, minimizing sample consumption.
Critical for planning sample volume and prep workflow.
Source
“Load your runs with just a single dilution and 2 µL of sample per well.”
Operation
Up to 288 samples can be queued for unattended operation.
Defines batch capacity and unattended run planning.
Source
“Queue up to 288 samples and walk away.”
Maintenance
Capillary conditioning can be automated to run before or after separations.
Supports scheduling unattended QC and reducing operator intervention.
Source
“automate maintenance tasks, such as capillary conditioning, to run before or after separations”
Cumplimiento
IQ/OQ services are available with purchase or on demand for qualification.
Important for regulated labs needing installation and operational qualification.
Source
“IQ/OQ services are also available with instrument purchase or on-demand.”
Maintenance
Standard warranty is one year and can be extended up to five years with preventive maintenance.
Affects total cost of ownership and service contract planning.
Source
“This may be upgraded to CrossLab Silver level and extended to cover up to five years total warranty time.”