Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH1 410 (Edición 01/2019): soplador de canal lateral con convertidor de frecuencia integrado, tamaño 2BH1410; variantes 2BH1410-1H346 (380 V, 87 Hz, 4,30 kW), 2BH1410-1HK36 (380 V, 50/60 Hz, 2,90 kW), 2BH1410-1HK46 (400 V, 50/60 Hz, 4,30 kW); módulos convertidores de frecuencia 2FC4xxx-1□□00 (tamaños A–K) y accesorios (terminal manual MMI, cable adaptador USB, transmisores de presión diferencial).
Technical Data
| Parameter |
Value |
Condición |
| Rated mains voltage |
380 V
p.2 ↗ |
2BH1410-1H346, 87 Hz |
| Rated motor current |
8,8 A
p.2 ↗ |
2BH1410-1H346, 87 Hz |
| Rated motor power |
4,30 kW
p.2 ↗ |
2BH1410-1H346, 87 Hz |
| Max. differential pressure (vacuum) |
-410 mbar
p.2 ↗ |
2BH1410-1H346, 87 Hz |
| Max. differential pressure (pressure) |
360 mbar
p.2 ↗ |
2BH1410-1H346, 87 Hz |
| Sound pressure level |
78 dB(A)
p.2 ↗ |
2BH1410-1H346, 87 Hz |
| Weight |
43 kg
p.2 ↗ |
2BH1410-1H346, 87 Hz |
| Rated mains voltage |
380 V
p.2 ↗ |
2BH1410-1HK36, 50/60 Hz |
| Rated motor power |
2,90 kW
p.2 ↗ |
2BH1410-1HK36, 50/60 Hz |
| Max. differential pressure (vacuum) |
-320 mbar
p.2 ↗ |
2BH1410-1HK36, 50 Hz |
| Max. differential pressure (pressure) |
420 mbar
p.2 ↗ |
2BH1410-1HK36, 50 Hz |
| Sound pressure level |
67 dB(A)
p.2 ↗ |
2BH1410-1HK36, 50 Hz |
| Weight |
36 kg
p.2 ↗ |
2BH1410-1HK36, 50/60 Hz |
| Rated mains voltage |
400 V
p.2 ↗ |
2BH1410-1HK46, 50/60 Hz |
| Rated motor current |
8,7 A
p.2 ↗ |
2BH1410-1HK46, 87 Hz |
| Rated motor power |
4,30 kW
p.2 ↗ |
2BH1410-1HK46, 50/60 Hz |
| Max. differential pressure (vacuum) |
-350 mbar
p.2 ↗ |
2BH1410-1HK46, 60 Hz |
| Max. differential pressure (pressure) |
440 mbar
p.2 ↗ |
2BH1410-1HK46, 60 Hz |
| Sound pressure level |
77 dB(A)
p.2 ↗ |
2BH1410-1HK46, 60 Hz |
| Weight |
38 kg
p.2 ↗ |
2BH1410-1HK46, 50/60 Hz |
| Rated mains voltage (frequency converter) |
380 V
p.1 ↗ |
minimum mains voltage for frequency converter operation |
| Rated voltage/frequency set point |
345 V / 87 Hz
p.1 ↗ |
frequency converter operation, delta connection |
| Minimum pulse frequency |
4 kHz
p.1 ↗ |
frequency converter operation |
| Suction and ambient temperature |
up to 25 °C
p.1 ↗ |
validity of total pressure differences |
| Performance curve tolerance |
± 10 %
p.1 ↗ |
air at 15 °C, 1013 mbar |
Operating Limits
- Suction and ambient temperature for rated pressure data: up to 25 °C
p.1 ↗
- Minimum mains voltage for frequency converter operation: 380 V
p.1 ↗
- Minimum pulse frequency of frequency converter: 4 kHz
p.1 ↗
- Performance curve tolerance: ± 10 %
p.1 ↗
Type Code Decoder
| Position |
Token |
Meaning |
| 1-6
p.2 ↗ |
2BH141 |
Side channel blower series 2BH1, size 410 |
| 8-9
p.2 ↗ |
1H |
Motor variant field (1H = standard motor) |
| field 1
p.2 ↗ |
A–K |
Frequency converter module size (2FC4xxx-1□□00) |
| field 2-3
p.2 ↗ |
□□ |
Frequency converter option placeholders (not specified in this document) |
Ordering Data
| Ordering Code |
Part No. |
Variant / Code |
Aplica a |
Note |
| 2BH1410-1H346
p.2 ↗ |
2BH1410-1H346 |
|
380 V, 87 Hz, 4.30 kW |
Blower with frequency-converter motor |
| 2BH1410-1HK36
p.2 ↗ |
2BH1410-1HK36 |
|
380 V, 50/60 Hz, 2.90 kW |
Blower with 50/60 Hz motor |
| 2BH1410-1HK46
p.2 ↗ |
2BH1410-1HK46 |
|
400 V, 50/60 Hz, 4.30 kW |
Blower with 50/60 Hz motor |