Technical Data Sheet — G-BH1 2BH1500 IE3 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH1 500: soplador de canal lateral con convertidor de frecuencia integrado (VFD). Abarca 2BH1500-1A336 (380 V, 87 Hz, 4.3 kW), 2BH1500-1AK26 (400 V, 50 Hz, 2.9 kW), 2BH1500-1AK36 (400 V, 87 Hz, 4.3 kW), además de los tipos con VFD integrado 2FC4xxx-1□□00 y accesorios.
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Rated motor voltage | 380 V p.2 ↗ | 2BH1500-1A336, 87 Hz |
| Rated motor current | 8,8 A p.2 ↗ | 2BH1500-1A336, 87 Hz |
| Motor power | 4,3 kW p.2 ↗ | 2BH1500-1A336, 87 Hz |
| Max. differential pressure, vacuum | -300 mbar p.2 ↗ | 2BH1500-1A336, 87 Hz |
| Max. differential pressure, pressure | 270 mbar p.2 ↗ | 2BH1500-1A336, 87 Hz |
| Sound pressure level | 78 dB(A) p.2 ↗ | 2BH1500-1A336, 87 Hz |
| Weight | 40,8 kg p.2 ↗ | 2BH1500-1A336, 87 Hz |
| Rated motor voltage | 400 V p.2 ↗ | 2BH1500-1AK26, 50 Hz |
| Motor power | 2,9 kW p.2 ↗ | 2BH1500-1AK26, 50 Hz |
| Max. differential pressure, vacuum | -250 mbar p.2 ↗ | 2BH1500-1AK26, 50 Hz |
| Max. differential pressure, pressure | 310 mbar p.2 ↗ | 2BH1500-1AK26, 50 Hz |
| Sound pressure level | 69 dB(A) p.2 ↗ | 2BH1500-1AK26, 50 Hz |
| Weight | 34 kg p.2 ↗ | 2BH1500-1AK26, 50 Hz |
| Rated motor voltage | 400 V p.2 ↗ | 2BH1500-1AK36, 87 Hz |
| Rated motor current | 8,7 A p.2 ↗ | 2BH1500-1AK36, 87 Hz |
| Motor power | 4,3 kW p.2 ↗ | 2BH1500-1AK36, 87 Hz |
| Max. differential pressure, vacuum | -300 mbar p.2 ↗ | 2BH1500-1AK36, 87 Hz |
| Max. differential pressure, pressure | 270 mbar p.2 ↗ | 2BH1500-1AK36, 87 Hz |
| Sound pressure level | 78 dB(A) p.2 ↗ | 2BH1500-1AK36, 87 Hz |
| Weight | 36 kg p.2 ↗ | 2BH1500-1AK36, 87 Hz |
| Protection class | IP55 p.2 ↗ | motor |
| Insulation material class | F p.2 ↗ | motor |
| VFD rated mains voltage | 3~ 400V -15% … 480V +10% V p.2 ↗ | integrated VFD |
| VFD mains frequency | 50/60 Hz p.2 ↗ | integrated VFD, ±6% |
Operating Limits
- Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
- Min. mains voltage for frequency converter: 380 V p.1 ↗
- Min. pulse frequency for performance curves: 4 kHz p.1 ↗
- Protection class: IP55 p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BH150 | Type/size designation (2BH1 500) |
| 11-12 p.2 ↗ | K2 | Voltage/frequency variant (K2 = 400 V, 50 Hz) |
| 11-12 p.2 ↗ | K3 | Voltage/frequency variant (K3 = 400 V, 87 Hz) |
| VFD field 1 p.2 ↗ | A-K | VFD size letter (A=1.5 kW … K=22 kW) |
| VFD field 2 p.2 ↗ | □ | Placeholder for voltage/frequency variant in VFD order number 2FC4xxx-1□□00 |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Aplica a | Note |
|---|---|---|---|---|
| 2BH1500-1A336 p.2 ↗ | 2BH1500-1A336 | 380 V, 87 Hz | Integrated VFD, 4.3 kW | |
| 2BH1500-1AK26 p.2 ↗ | 2BH1500-1AK26 | 400 V, 50 Hz | 2.9 kW | |
| 2BH1500-1AK36 p.2 ↗ | 2BH1500-1AK36 | 400 V, 87 Hz | 4.3 kW |
Modelos relacionados
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943