Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 2BH1510 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 510: soplador de canal lateral con convertidor de frecuencia integrado (VFD), tipo 2BH1 510. Variantes: 2BH1510-1H346 (VFD tipo E, 5,8 kW) y 2BH1510-1H356 (VFD tipo F, 7,5 kW); 2BH1510-1HK46 / 2BH1510-1HK56 con ventilador accionado por separado (opción de pedido G17). VFD integrado: 3~ 400 V -15% … 480 V +10%, 50/60 Hz ±6%, termistor (PTC), IP55, UL 1450. Motor: 3~ 50/60 Hz, IP55, clase de aislamiento F, UL 1450 y CAN/CSA C22.2 No. 68-09 (número de certificado E225239).

Technical Data

Parameter Value Condición
Rated motor voltage 380 V p.2 ↗ 2BH1510-1H346, 87 Hz, U connection
Rated motor current 11,5 A p.2 ↗ 2BH1510-1H346, 87 Hz, U connection
Rated motor power 5,8 kW p.2 ↗ 2BH1510-1H346, 87 Hz
Max. differential pressure, vacuum -370 mbar p.2 ↗ 2BH1510-1H346, 87 Hz
Max. differential pressure, pressure 300 mbar p.2 ↗ 2BH1510-1H346, 87 Hz
Sound pressure level 81 dB(A) p.2 ↗ 2BH1510-1H346, 87 Hz
Weight 57 kg p.2 ↗ 2BH1510-1H346, 87 Hz
Rated motor voltage 380 V p.2 ↗ 2BH1510-1H356, 87 Hz, U connection
Rated motor current 15,9 A p.2 ↗ 2BH1510-1H356, 87 Hz, U connection
Rated motor power 7,5 kW p.2 ↗ 2BH1510-1H356, 87 Hz
Max. differential pressure, vacuum -460 mbar p.2 ↗ 2BH1510-1H356, 87 Hz
Max. differential pressure, pressure 470 mbar p.2 ↗ 2BH1510-1H356, 87 Hz
Sound pressure level 81 dB(A) p.2 ↗ 2BH1510-1H356, 87 Hz
Weight 60 kg p.2 ↗ 2BH1510-1H356, 87 Hz
Rated motor voltage 400 V p.2 ↗ 2BH1510-1HK46, 87 Hz, D connection
Rated motor current 11,0 A p.2 ↗ 2BH1510-1HK46, 87 Hz, D connection
Rated motor power 5,8 kW p.2 ↗ 2BH1510-1HK46, 87 Hz
Max. differential pressure, vacuum -370 mbar p.2 ↗ 2BH1510-1HK46, 87 Hz
Max. differential pressure, pressure 300 mbar p.2 ↗ 2BH1510-1HK46, 87 Hz
Sound pressure level 81 dB(A) p.2 ↗ 2BH1510-1HK46, 87 Hz
Weight 74/75 kg p.2 ↗ 2BH1510-1HK46, 87 Hz
Rated motor voltage 400 V p.2 ↗ 2BH1510-1HK56, 87 Hz, D connection
Rated motor current 15,6 A p.2 ↗ 2BH1510-1HK56, 87 Hz, D connection
Rated motor power 7,5 kW p.2 ↗ 2BH1510-1HK56, 87 Hz
Max. differential pressure, vacuum -460 mbar p.2 ↗ 2BH1510-1HK56, 87 Hz

Operating Limits

  • Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Integrated VFD mains voltage range: 400 V -15% … 480 V +10% p.2 ↗
  • Integrated VFD mains frequency: 50/60 Hz ±6% p.2 ↗
  • Protection class (motor and VFD): IP55 p.2 ↗
  • Insulation material class: F p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH151 Type / size designation (2BH1 510 side channel blower)
10-11 p.2 ↗ K4 Separately driven fan (order option G17), 5.8 kW
10-11 p.2 ↗ K6 Separately driven fan (order option G17), 7.5 kW

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH1510-1H346 p.2 ↗ 2BH1510-1H346 E 87 Hz, 380 V U connection, 5.8 kW Integrated VFD type E
2BH1510-1H356 p.2 ↗ 2BH1510-1H356 F 87 Hz, 380 V U connection, 7.5 kW Integrated VFD type F
2BH1510-1HK46 p.2 ↗ 2BH1510-1HK46 87 Hz, 400 V D connection, 5.8 kW With separately driven fan (order option G17)
2BH1510-1HK56 p.2 ↗ 2BH1510-1HK56 87 Hz, 400 V D connection, 7.5 kW With separately driven fan (order option G17)