Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 2BH1530 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 530: soplador de canal lateral con convertidor de frecuencia integrado (VFD), 3~ 400 V -15% … 480 V +10%, 50/60 Hz ±6%, IP55, UL 1450; funcionamiento con VFD con consigna de tensión/frecuencia nominal 345 V / 87 Hz, conexión en triángulo, red mínima 380 V; número de pedido de la boca de aspiración 2BH1530-7E□□□.

Technical Data

Parameter Value Condición
Rated voltage 380 V p.2 ↗ 2BH1 530, 87 Hz, delta
Rated motor current 8,8 A p.2 ↗ 2BH1 530, 87 Hz, delta
Rated motor power 4,3 kW p.2 ↗ 2BH1 530, 87 Hz, delta
Max. differential pressure, vacuum -210 mbar p.2 ↗ 2BH1 530, 87 Hz, delta
Max. differential pressure, pressure 190 mbar p.2 ↗ 2BH1 530, 87 Hz, delta
Sound pressure level 78 dB(A) p.2 ↗ 2BH1 530, 87 Hz, delta
Weight 41 kg p.2 ↗ 2BH1 530, 87 Hz, delta
Max. differential pressure, vacuum -140 mbar p.2 ↗ 2BH1 530, 37 Hz
Max. differential pressure, pressure 160 mbar p.2 ↗ 2BH1 530, 37 Hz
Sound pressure level 64 dB(A) p.2 ↗ 2BH1 530, 37 Hz
Max. differential pressure, vacuum -180 mbar p.2 ↗ 2BH1 530, 50 Hz
Max. differential pressure, pressure 170 mbar p.2 ↗ 2BH1 530, 50 Hz
Sound pressure level 64 dB(A) p.2 ↗ 2BH1 530, 50 Hz
Weight 32 kg p.2 ↗ 2BH1 530, 50 Hz
Max. differential pressure, vacuum -160 mbar p.2 ↗ 2BH1 530, 60 Hz
Max. differential pressure, pressure 140 mbar p.2 ↗ 2BH1 530, 60 Hz
Sound pressure level 72 dB(A) p.2 ↗ 2BH1 530, 60 Hz
Rated voltage 400 V p.2 ↗ 2BH1 530, 87 Hz, delta
Rated motor current 5,8 A p.2 ↗ 2BH1 530, 87 Hz, delta
Rated motor power 2,9 kW p.2 ↗ 2BH1 530, 87 Hz, delta
Max. differential pressure, vacuum -50 mbar p.2 ↗ 2BH1 530, 87 Hz, delta
Max. differential pressure, pressure 40 mbar p.2 ↗ 2BH1 530, 87 Hz, delta
Sound pressure level 77 dB(A) p.2 ↗ 2BH1 530, 87 Hz, delta
Weight 36 kg p.2 ↗ 2BH1 530, 87 Hz, delta
Rated motor current 8,7 A p.2 ↗ 2BH1 530, 87 Hz, delta

Operating Limits

  • Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Minimum pulse frequency for frequency converter operation: 4 kHz p.1 ↗
  • Minimum mains voltage for frequency converter: 380 V p.1 ↗
  • Protection class: IP55 p.2 ↗
  • Insulation material class: F p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH153 Type/size designation of side channel blower 2BH1 530
7-8 p.2 ↗ 0- Separator in order number
12-13 p.2 ↗ 36 / 26 Size/speed variant suffix (36 or 26)

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH1530-1A336 p.2 ↗ 2BH1530-1A336 380 V, 87 Hz, delta, VFD type D Order No. for 2BH1 530, 87 Hz, 380 V
2BH1530-1AK26 p.2 ↗ 2BH1530-1AK26 50/60 Hz, VFD type C Order No. for 2BH1 530, 50/60 Hz
2BH1530-1AK36 p.2 ↗ 2BH1530-1AK36 400 V, 87 Hz, delta, VFD type D Order No. for 2BH1 530, 87 Hz, 400 V