Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — 2BH1610 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 610: sopladores de canal lateral con motores IE3, 3~ 50/60 Hz, IP55, clase de aislamiento F, UL 1450 y CAN/CSA C22.2 N.º 68-09 (certificado E225239). Abarca los tamaños 1-5 con variantes de tensión HK (190-210/380-420 V, 220-240/380-420 V), HQ (475-525/550-600 V, 380-420/660-725 V, 220-240/440-480 V) y variantes NP de 60 Hz.

Technical Data

Parameter Value Condición
Rated pressure 2,50 kW p.2 ↗ 2BH1610-0HK11, 50 Hz
Max. differential pressure -170 mbar p.2 ↗ 2BH1610-0HK11, 50 Hz
Sound pressure level 69 dB(A) p.2 ↗ 2BH1610-0HK11, 50 Hz
Weight 48 kg p.2 ↗ 2BH1610-0HK11
Rated pressure 3,45 kW p.2 ↗ 2BH1610-1HK21, 50 Hz
Max. differential pressure -270 mbar p.2 ↗ 2BH1610-1HK21, 50 Hz
Sound pressure level 75 dB(A) p.2 ↗ 2BH1610-1HK21, 50 Hz
Weight 58 kg p.2 ↗ 2BH1610-1HK21
Rated pressure 4,6 kW p.2 ↗ 2BH1610-1HK31, 50 Hz
Max. differential pressure -400 mbar p.2 ↗ 2BH1610-1HK31, 50 Hz
Sound pressure level 67 dB(A) p.2 ↗ 2BH1610-1HK31, 50 Hz
Weight 65 kg p.2 ↗ 2BH1610-1HK31
Rated pressure 6,3 kW p.2 ↗ 2BH1610-1HK41, 50 Hz
Max. differential pressure -420 mbar p.2 ↗ 2BH1610-1HK41, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1610-1HK41, 50 Hz
Weight 73 kg p.2 ↗ 2BH1610-1HK41
Rated pressure 8,6 kW p.2 ↗ 2BH1610-1HK51, 50 Hz
Max. differential pressure -420 mbar p.2 ↗ 2BH1610-1HK51, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1610-1HK51, 50 Hz
Weight 85 kg p.2 ↗ 2BH1610-1HK51
Rated pressure 3,00 kW p.2 ↗ 2BH1610-0HK11, 60 Hz
Max. differential pressure -130 mbar p.2 ↗ 2BH1610-0HK11, 60 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BH1610-0HK11, 60 Hz
Protection class IP55 p.2 ↗
Insulation class F p.2 ↗

Operating Limits

  • Max. ambient/suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Protection class: IP55 p.2 ↗
  • Insulation class: F p.2 ↗

Type Code Decoder

Position Token Meaning
1-5 p.2 ↗ 2BH1 Series: side channel blower
6-9 p.2 ↗ 610 Size 610
12-13 p.2 ↗ HK/HQ Voltage/frequency variant family

Modelos relacionados