Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 2BH1630 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Soplador de canal lateral tipo 2BH1 630 (serie G-BH1), variantes de 50 Hz y 60 Hz, rangos de tensión 185-225 D / 320-390 Y, 200-240 D / 345-415 Y, 345-415 D / 600-720 Y, 500 Y, 500 D, 475-525 V Y, 475-525 V D, versiones de tensión fija y VFD (87 Hz); números de pedido 2BH1630-1AH26, 2BH1630-1AH36, 2BH1630-1AC23, 2BH1630-1AC33; código de pedido con boca de aspiración en la tapa del soplador 2BH1630-1E□□□

Technical Data

Parameter Value Condición
Rated frequency 50 Hz p.2 ↗ 2BH1630-1AH26
Voltage 200-240 / 345-415 Y V p.2 ↗ 2BH1630-1AH26, 50 Hz
Current 12,5 / 7,2 Y A p.2 ↗ 2BH1630-1AH26, 50 Hz
Power 3,0 kW p.2 ↗ 2BH1630-1AH26, 50 Hz
Max. differential pressure vacuum -220 mbar p.2 ↗ 2BH1630-1AH26, 50 Hz
Max. differential pressure pressure 200 mbar p.2 ↗ 2BH1630-1AH26, 50 Hz
Sound pressure level 38 dB(A) p.2 ↗ 2BH1630-1AH26, 50 Hz
Weight 38 kg p.2 ↗ 2BH1630-1AH26
Rated frequency 60 Hz p.2 ↗ 2BH1630-1AH26
Voltage 220-275 / 380-480 Y V p.2 ↗ 2BH1630-1AH26, 60 Hz
Current 12,6 / 7,3 Y A p.2 ↗ 2BH1630-1AH26, 60 Hz
Power 3,45 kW p.2 ↗ 2BH1630-1AH26, 60 Hz
Max. differential pressure vacuum -200 mbar p.2 ↗ 2BH1630-1AH26, 60 Hz
Max. differential pressure pressure 170 mbar p.2 ↗ 2BH1630-1AH26, 60 Hz
Power 4,0 kW p.2 ↗ 2BH1630-1AH36, 50 Hz
Max. differential pressure vacuum -260 mbar p.2 ↗ 2BH1630-1AH36, 50 Hz
Max. differential pressure pressure 290 mbar p.2 ↗ 2BH1630-1AH36, 50 Hz
Sound pressure level 48 dB(A) p.2 ↗ 2BH1630-1AH36, 50 Hz
Weight 48 kg p.2 ↗ 2BH1630-1AH36
Power 3,0 kW p.2 ↗ 2BH1630-1AC23, 50 Hz
Max. differential pressure vacuum -220 mbar p.2 ↗ 2BH1630-1AC23, 50 Hz
Max. differential pressure pressure 200 mbar p.2 ↗ 2BH1630-1AC23, 50 Hz
Power 4,0 kW p.2 ↗ 2BH1630-1AC33, 50 Hz
Max. differential pressure vacuum -260 mbar p.2 ↗ 2BH1630-1AC33, 50 Hz
Max. differential pressure pressure 290 mbar p.2 ↗ 2BH1630-1AC33, 50 Hz

Operating Limits

  • Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Frequency tolerance: +/- 2 % maximum p.2 ↗
  • Max. converter input voltage for standard motor insulation: 460 V p.2 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH1630 Type / size designation (side channel blower 2BH1 630)
field 1 p.2 ↗ H / C Voltage range group: H = 185-225 D / 320-390 Y (50 Hz) and 200-240 D / 345-415 Y (60 Hz); C = 500 Y (50 Hz) and 575 Y (60 Hz)
field 2 p.2 ↗ 1 / 6 / 7 / 3 / 5 Voltage variant within the group (e.g. H1, H6, H7, C3, C5)
field 3 p.2 ↗ A / K / Q Motor / voltage option: A = standard voltage range, K = fixed voltage, Q = 475-525 V Y / 550-600 V Y or 475-525 V D / 550-600 V D
field 4 p.2 ↗ 2 / 3 Power size: 2 = 3,0 kW (50 Hz) / 3,45 kW (60 Hz); 3 = 4,0 kW (50 Hz) / 4,6 kW (60 Hz)
field 5 p.2 ↗ 6 / 3 Voltage code: 6 = 200-240 D / 345-415 Y (50 Hz) and 220-275 D / 380-480 Y (60 Hz); 3 = 500 Y (50 Hz) and 575 Y (60 Hz)
field 6 p.2 ↗ □ Placeholder for voltage / frequency option in ordering code 2BH1630-..□.□
field 7 p.2 ↗ □ Placeholder for second option field in ordering code 2BH1630-..□.□

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH1630-1AH26 p.2 ↗ 2BH1630-1AH26 50 Hz / 60 Hz, 200-240 D / 345-415 Y (50 Hz), 220-275 D / 380-480 Y (60 Hz) 3,0 kW at 50 Hz, 3,45 kW at 60 Hz
2BH1630-1AH36 p.2 ↗ 2BH1630-1AH36 50 Hz / 60 Hz, 200-240 D / 345-415 Y (50 Hz), 220-275 D / 380-480 Y (60 Hz) 4,0 kW at 50 Hz, 4,6 kW at 60 Hz
2BH1630-1AC23 p.2 ↗ 2BH1630-1AC23 50 Hz / 60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) 3,0 kW at 50 Hz, 3,45 kW at 60 Hz
2BH1630-1AC33 p.2 ↗ 2BH1630-1AC33 50 Hz / 60 Hz, 500 Y (50 Hz), 575 Y (60 Hz) 4,0 kW at 50 Hz, 4,6 kW at 60 Hz