Technical Data Sheet — G-BH1 2BH1640 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos del soplador de canal lateral 2BH1 640 (serie G-BH1). Abarca los tamaños 1, 2, 3 con prestaciones a 50 Hz y 60 Hz, variantes de tensión H (345-415 D / 600-720 Y; 380-480 D), C (500 Y; 575 Y), K (200 YY / 230 D / 400 Y; 230 YY / 460 Y), Q (400 VD / 690 V Y; 460 VD; 475-525 V Y / 550-600 V Y; 475-525 VD / 550-600 VD), y números de pedido 2BH1640-1GH37, -1GH47, -1GH57, -1GC33, -1GC43, -1GC53.

Technical Data

Parameter Value Condición
Rated pressure (vacuum) -150 mbar p.2 ↗ 2BH1640-1GH37, size 1, 50 Hz
Rated pressure (vacuum) -100 mbar p.2 ↗ 2BH1640-1GH37, size 1, 60 Hz
Rated pressure (vacuum) -240 mbar p.2 ↗ 2BH1640-1GH47, size 2, 50 Hz
Rated pressure (vacuum) -210 mbar p.2 ↗ 2BH1640-1GH47, size 2, 60 Hz
Rated pressure (vacuum) -240 mbar p.2 ↗ 2BH1640-1GH57, size 3, 50 Hz
Rated pressure (vacuum) -270 mbar p.2 ↗ 2BH1640-1GH57, size 3, 60 Hz
Max. differential pressure (vacuum) 140 mbar p.2 ↗ 2BH1640-1GH37, size 1, 50 Hz
Max. differential pressure (vacuum) 90 mbar p.2 ↗ 2BH1640-1GH37, size 1, 60 Hz
Max. differential pressure (vacuum) 260 mbar p.2 ↗ 2BH1640-1GH47, size 2, 50 Hz
Max. differential pressure (vacuum) 200 mbar p.2 ↗ 2BH1640-1GH47, size 2, 60 Hz
Max. differential pressure (vacuum) 320 mbar p.2 ↗ 2BH1640-1GH57, size 3, 50 Hz
Max. differential pressure (vacuum) 300 mbar p.2 ↗ 2BH1640-1GH57, size 3, 60 Hz
Voltage 345-415 D / 600-720 Y V p.2 ↗ 2BH1640-1GH37, size 1, 50 Hz
Voltage 380-480 D V p.2 ↗ 2BH1640-1GH37, size 1, 60 Hz
Voltage 345-415 D / 600-720 Y V p.2 ↗ 2BH1640-1GH47, size 2, 50 Hz
Voltage 380-480 D V p.2 ↗ 2BH1640-1GH47, size 2, 60 Hz
Voltage 345-415 D / 600-720 Y V p.2 ↗ 2BH1640-1GH57, size 3, 50 Hz
Voltage 380-480 D V p.2 ↗ 2BH1640-1GH57, size 3, 60 Hz
Current 10,0 D / 5,8 Y A p.2 ↗ 2BH1640-1GH37, size 1, 50 Hz
Current 10,4 D A p.2 ↗ 2BH1640-1GH37, size 1, 60 Hz
Current 13,3 D / 7,7 Y A p.2 ↗ 2BH1640-1GH47, size 2, 50 Hz
Current 13,3 A p.2 ↗ 2BH1640-1GH47, size 2, 60 Hz
Current 16,7 D / 9,6 Y A p.2 ↗ 2BH1640-1GH57, size 3, 50 Hz
Current 17,3 D A p.2 ↗ 2BH1640-1GH57, size 3, 60 Hz
Power 4,3 kW p.2 ↗ 2BH1640-1GH37, size 1, 50 Hz

Operating Limits

  • Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Operation: continuous operation over total performance curve range p.1 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH1640 Type designation: side channel blower, size 640

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH1640-1GH37 p.2 ↗ 2BH1640-1GH37 H Size 1, voltage variant H (345-415 D / 600-720 Y at 50 Hz; 380-480 D at 60 Hz) Order No. as printed
2BH1640-1GH47 p.2 ↗ 2BH1640-1GH47 H Size 2, voltage variant H (345-415 D / 600-720 Y at 50 Hz; 380-480 D at 60 Hz) Order No. as printed
2BH1640-1GH57 p.2 ↗ 2BH1640-1GH57 H Size 3, voltage variant H (345-415 D / 600-720 Y at 50 Hz; 380-480 D at 60 Hz) Order No. as printed
2BH1640-1GC33 p.2 ↗ 2BH1640-1GC33 C Size 1, voltage variant C (500 Y at 50 Hz; 575 Y at 60 Hz) Order No. as printed
2BH1640-1GC43 p.2 ↗ 2BH1640-1GC43 C Size 2, voltage variant C (500 Y at 50 Hz; 575 Y at 60 Hz) Order No. as printed
2BH1640-1GC53 p.2 ↗ 2BH1640-1GC53 C Size 3, voltage variant C (500 Y at 50 Hz; 575 Y at 60 Hz) Order No. as printed