Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH1 690: soplador de canal lateral con motores IE3, 3~ 50/60 Hz, IP55, clase de aislamiento F, UL 1450 y CAN/CSA C22.2 No. 68-09 (E225239). Cubre el tipo 2BH1690 con varias variantes de tensión/frecuencia (AK11, AK21, AK16, AK26, AQ13, AQ23, AQ17, AQ27, AQ16, AQ26) y opciones de motor de tensión alternativa (Z=K1, Q3, Q5, Q7).
Technical Data
| Parameter |
Value |
Condición |
| Rated voltage |
190-210 V
p.2 ↗ |
2BH1690-0AK11, 50 Hz, Δ |
| Rated current |
9,9 A
p.2 ↗ |
2BH1690-0AK11, 50 Hz, Δ |
| Power |
2,50 kW
p.2 ↗ |
2BH1690-0AK11, 50 Hz |
| Max. differential pressure, vacuum |
-200 mbar
p.2 ↗ |
2BH1690-0AK11, 50 Hz |
| Max. differential pressure, pressure |
170 mbar
p.2 ↗ |
2BH1690-0AK11, 50 Hz |
| Sound pressure level |
64 dB(A)
p.2 ↗ |
2BH1690-0AK11, 50 Hz |
| Weight approx. |
34 kg
p.2 ↗ |
2BH1690-0AK11, 50 Hz |
| Efficiency class |
IE3
p.2 ↗ |
2BH1690-0AK11, 50 Hz |
| Rated voltage |
190-210 ΥΥ / 380-420 Υ V
p.2 ↗ |
2BH1690-0AK11, 60 Hz |
| Rated current |
12,0 ΥΥ / 6,0 Υ A
p.2 ↗ |
2BH1690-0AK11, 60 Hz |
| Power |
3,00 kW
p.2 ↗ |
2BH1690-0AK11, 60 Hz |
| Max. differential pressure, vacuum |
-190 mbar
p.2 ↗ |
2BH1690-0AK11, 60 Hz |
| Max. differential pressure, pressure |
170 mbar
p.2 ↗ |
2BH1690-0AK11, 60 Hz |
| Sound pressure level |
70 dB(A)
p.2 ↗ |
2BH1690-0AK11, 60 Hz |
| Rated voltage |
190-210 V
p.2 ↗ |
2BH1690-0AK21, 50 Hz, Δ |
| Rated current |
13,3 A
p.2 ↗ |
2BH1690-0AK21, 50 Hz, Δ |
| Power |
3,45 kW
p.2 ↗ |
2BH1690-0AK21, 50 Hz |
| Max. differential pressure, vacuum |
-200 mbar
p.2 ↗ |
2BH1690-0AK21, 50 Hz |
| Max. differential pressure, pressure |
250 mbar
p.2 ↗ |
2BH1690-0AK21, 50 Hz |
| Sound pressure level |
71 dB(A)
p.2 ↗ |
2BH1690-0AK21, 50 Hz |
| Weight approx. |
38 kg
p.2 ↗ |
2BH1690-0AK21, 50 Hz |
| Rated voltage |
190-210 ΥΥ / 380-420 Υ V
p.2 ↗ |
2BH1690-0AK21, 60 Hz |
| Rated current |
15,2 ΥΥ / 7,6 Υ A
p.2 ↗ |
2BH1690-0AK21, 60 Hz |
| Power |
4,0 kW
p.2 ↗ |
2BH1690-0AK21, 60 Hz |
| Max. differential pressure, vacuum |
-240 mbar
p.2 ↗ |
2BH1690-0AK21, 60 Hz |
Operating Limits
- Max. ambient/suction temperature for stated total pressure differences: 25 °C
p.1 ↗
- Performance curve tolerance: ± 10 %
p.1 ↗
- Protection category: IP 55
p.1 ↗
- Insulation class: F
p.1 ↗
Type Code Decoder
| Position |
Token |
Meaning |
| 1-7
p.2 ↗ |
2BH1690 |
Type / size designation (side channel blower 2BH1, size 690) |
| field 1
p.2 ↗ |
0 |
Series/variant field |
| field 2
p.2 ↗ |
A |
Motor/voltage variant family (A = standard IE3 motor) |
| field 3
p.2 ↗ |
K / Q |
Voltage/motor variant letter (K = 190-210 V, Q = 500/575 V or 380-725 V variants) |
| field 4
p.2 ↗ |
1 / 2 |
Performance size within type (1 = 2,50/3,00 kW, 2 = 3,45/4,0 kW) |
| field 5
p.2 ↗ |
1 / 6 / 3 / 7 |
Voltage/frequency variant code (e.g. 1 = 190-210 V, 6 = 220-240/380-420 V, 3 = 500/575 V, 7 = 380-725 V) |
| Z= field
p.2 ↗ |
K1 / Q3 / Q5 / Q7 |
Motor for alternate voltages option (Z=K1, Q3, Q5, Q7) |
Ordering Data
| Ordering Code |
Part No. |
Variant / Code |
Aplica a |
Note |
| 2BH1690-0AK11
p.2 ↗ |
2BH1690-0AK11 |
|
50/60 Hz, 190-210 V / 380-420 V |
IE3, 2,50/3,00 kW |
| 2BH1690-0AK21
p.2 ↗ |
2BH1690-0AK21 |
|
50/60 Hz, 190-210 V / 380-420 V |
IE3, 3,45/4,0 kW |
| 2BH1690-0AK16
p.2 ↗ |
2BH1690-0AK16 |
|
50/60 Hz, 220-240 V / 380-480 V |
IE3, 2,50/3,00 kW |
| 2BH1690-0AK26
p.2 ↗ |
2BH1690-0AK26 |
|
50/60 Hz, 220-240 V / 380-480 V |
IE3, 3,45/4,0 kW |
| 2BH1690-0AQ13
p.2 ↗ |
2BH1690-0AQ13 |
|
50/60 Hz, 500/575 V |
IE3, 2,50/3,00 kW |
| 2BH1690-0AQ23
p.2 ↗ |
2BH1690-0AQ23 |
|
50/60 Hz, 500/575 V |
IE3, 3,45/4,00 kW |
| 2BH1690-0AQ17
p.2 ↗ |
2BH1690-0AQ17 |
|
50/60 Hz, 380-420/660-725 V |
IE3, 2,90/3,0 kW |
| 2BH1690-0AQ27
p.2 ↗ |
2BH1690-0AQ27 |
|
50/60 Hz, 380-420/660-725 V |
IE3, 3,45/4,0 kW |
| 2BH1690-0AQ16
p.2 ↗ |
2BH1690-0AQ16 |
|
50/60 Hz, 220-240/380-420 V |
IE3, 2,50/3,00 kW |
| 2BH1690-0AQ26
p.2 ↗ |
2BH1690-0AQ26 |
|
50/60 Hz, 220-240/380-420 V |
IE3, 3,45/4,0 kW |