Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 2BH1690 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos del soplador de canal lateral 2BH1 690 (serie G-BH1), que abarca 2BH1690-1AH26 y 2BH1690-1AC23 con datos de 50 Hz y 60 Hz, además de variantes de motor de tensión alternativa seleccionables mediante el código de pedido 2BH1690-..□.□ (códigos de tensión 1, 3, 5, 6, 7 y códigos de eficiencia/motor C, H, K, Q).

Technical Data

Parameter Value Condición
Rated pressure (vacuum) -160 mbar p.2 ↗ 2BH1690-1AH26, 50 Hz
Rated pressure (vacuum) -240 mbar p.2 ↗ 2BH1690-1AH26, 60 Hz
Max. differential pressure (pressure) 200 mbar p.2 ↗ 2BH1690-1AH26, 50 Hz
Max. differential pressure (pressure) 250 mbar p.2 ↗ 2BH1690-1AH26, 60 Hz
Voltage 200-240 D / 345-415 Y V p.2 ↗ 2BH1690-1AH26, 50 Hz
Voltage 220-275 D / 380-480 Y V p.2 ↗ 2BH1690-1AH26, 60 Hz
Current 12,5 D / 7,2 Y A p.2 ↗ 2BH1690-1AH26, 50 Hz
Current 12,6 D / 7,3 Y A p.2 ↗ 2BH1690-1AH26, 60 Hz
Power 3,0 kW p.2 ↗ 2BH1690-1AH26, 50 Hz
Power 3,45 kW p.2 ↗ 2BH1690-1AH26, 60 Hz
Noise level 71 dB(A) p.2 ↗ 2BH1690-1AH26, 50 Hz
Noise level 75 dB(A) p.2 ↗ 2BH1690-1AH26, 60 Hz
Weight 37 kg p.2 ↗ 2BH1690-1AH26
Rated pressure (vacuum) -160 mbar p.2 ↗ 2BH1690-1AC23, 50 Hz
Rated pressure (vacuum) -240 mbar p.2 ↗ 2BH1690-1AC23, 60 Hz
Max. differential pressure (pressure) 200 mbar p.2 ↗ 2BH1690-1AC23, 50 Hz
Max. differential pressure (pressure) 250 mbar p.2 ↗ 2BH1690-1AC23, 60 Hz
Voltage 500 Y V p.2 ↗ 2BH1690-1AC23, 50 Hz
Current 5,7 Y A p.2 ↗ 2BH1690-1AC23, 50 Hz
Current 5,8 Y A p.2 ↗ 2BH1690-1AC23, 60 Hz
Power 3,0 kW p.2 ↗ 2BH1690-1AC23, 50 Hz
Power 3,45 kW p.2 ↗ 2BH1690-1AC23, 60 Hz
Noise level 71 dB(A) p.2 ↗ 2BH1690-1AC23, 50 Hz
Noise level 75 dB(A) p.2 ↗ 2BH1690-1AC23, 60 Hz
Weight 37 kg p.2 ↗ 2BH1690-1AC23

Operating Limits

  • Max. ambient/suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH1690 Type/size designation of the side channel blower
field 1 p.2 ↗ 1 Motor variant / series field (as printed in 2BH1690-1...)
field 2 p.2 ↗ A Motor type field (as printed in 2BH1690-1A...)
field 3 p.2 ↗ H / C Efficiency/motor variant: H = standard efficiency, C = NEMA Premium/IE3 variant
field 4 p.2 ↗ 2 Voltage code: 200-240 D / 345-415 Y (50 Hz), 220-275 D / 380-480 Y (60 Hz)
field 4 p.2 ↗ 3 Voltage code: 500 Y (50 Hz), 575 Y (60 Hz)
field 4 p.2 ↗ 5 Voltage code: 500 D (50 Hz), 575 D (60 Hz)
field 4 p.2 ↗ 6 Voltage code: 200-240 / 345-415 Y (50 Hz), 220-275 / 380-480 Y (60 Hz), fixed 380 V at 87 Hz
field 4 p.2 ↗ 7 Voltage code: 345-415 D / 600-720 Y (50 Hz), 380-480 D / 660-720 Y (60 Hz), fixed 380 V at 87 Hz
field 4 p.2 ↗ 1 Voltage code: 185-225 D / 320-390 Y (50 Hz), 200-240 D / 345-415 Y (60 Hz), fixed 380 V at 87 Hz
field 5 p.2 ↗ 1 / 3 / 5 / 6 / 7 Second placeholder in 2BH1690-..□.□ selecting voltage range / efficiency variant combination