Covered Models & Document Scope
Hoja de datos 2BH1 900: sopladores de canal lateral con motores IE3, 3~ 50/60 Hz, IP55, clase de aislamiento F, UL 1450 y CAN/CSA C22.2 No. 68-09 (certificado E225239). Abarca los tamaños 1 y 2 con números de pedido 2BH1900-2AK11, -2AK21, -2AK16, -2AK26, -2AQ13, -2AQ23, -2AQ17, -2AQ27 y variantes de motor con tensión alternativa 2BH1…-2.□.□.
Technical Data
| Parameter |
Value |
Condición |
| Rated voltage |
190-210 V
p.2 ↗ |
2BH1900-2AK11, 50 Hz, D |
| Rated current |
35,0 A
p.2 ↗ |
2BH1900-2AK11, 50 Hz, D |
| Power |
9,0 kW
p.2 ↗ |
2BH1900-2AK11, 50 Hz |
| Max. differential pressure, vacuum |
-240 mbar
p.2 ↗ |
2BH1900-2AK11, 50 Hz |
| Max. differential pressure, pressure |
220 mbar
p.2 ↗ |
2BH1900-2AK11, 50 Hz |
| Sound pressure level |
74 dB(A)
p.2 ↗ |
2BH1900-2AK11, 50 Hz |
| Efficiency class |
IE3
p.2 ↗ |
2BH1900-2AK11, 50 Hz |
| Weight approx. |
232 kg
p.2 ↗ |
2BH1900-2AK11 |
| Rated voltage |
190-210 UU / 380-420 U V
p.2 ↗ |
2BH1900-2AK11, 60 Hz |
| Rated current |
41,2 UU / 20,6 U A
p.2 ↗ |
2BH1900-2AK11, 60 Hz |
| Power |
11,0 kW
p.2 ↗ |
2BH1900-2AK11, 60 Hz |
| Max. differential pressure, vacuum |
-230 mbar
p.2 ↗ |
2BH1900-2AK11, 60 Hz |
| Max. differential pressure, pressure |
200 mbar
p.2 ↗ |
2BH1900-2AK11, 60 Hz |
| Sound pressure level |
78 dB(A)
p.2 ↗ |
2BH1900-2AK11, 60 Hz |
| Rated voltage |
190-210 V
p.2 ↗ |
2BH1900-2AK21, 50 Hz, D |
| Rated current |
52,0 A
p.2 ↗ |
2BH1900-2AK21, 50 Hz, D |
| Power |
13,3 kW
p.2 ↗ |
2BH1900-2AK21, 50 Hz |
| Max. differential pressure, vacuum |
-240 mbar
p.2 ↗ |
2BH1900-2AK21, 50 Hz |
| Max. differential pressure, pressure |
270 mbar
p.2 ↗ |
2BH1900-2AK21, 50 Hz |
| Sound pressure level |
74 dB(A)
p.2 ↗ |
2BH1900-2AK21, 50 Hz |
| Weight approx. |
240 kg
p.2 ↗ |
2BH1900-2AK21 |
| Power |
16,0 kW
p.2 ↗ |
2BH1900-2AK21, 60 Hz |
| Max. differential pressure, vacuum |
-250 mbar
p.2 ↗ |
2BH1900-2AK21, 60 Hz |
| Max. differential pressure, pressure |
260 mbar
p.2 ↗ |
2BH1900-2AK21, 60 Hz |
| Sound pressure level |
78 dB(A)
p.2 ↗ |
2BH1900-2AK21, 60 Hz |
Operating Limits
- Protection category: IP55
p.2 ↗
- Insulation material class: F
p.2 ↗
- Suction and ambient temperature for stated total pressure differences: up to 25 °C
p.1 ↗
- Performance curve tolerance: ± 10 %
p.1 ↗
- Reference air temperature for performance curves: 15 °C
p.1 ↗
- Reference atmospheric pressure for performance curves: 1013 mbar
p.1 ↗
Type Code Decoder
| Position |
Token |
Meaning |
| 1-5
p.2 ↗ |
2BH1 |
Side channel blower series |
| 6-8
p.2 ↗ |
900 |
Size 900 |
Ordering Data
| Ordering Code |
Part No. |
Variant / Code |
Aplica a |
Note |
| 2BH1900-2AK11
p.2 ↗ |
2BH1900-2AK11 |
|
50/60 Hz, 190-210 V D / 380-420 V U |
Size 1, IE3 |
| 2BH1900-2AK21
p.2 ↗ |
2BH1900-2AK21 |
|
50/60 Hz, 190-210 V D / 380-420 V U |
Size 2, IE3 |
| 2BH1900-2AK16
p.2 ↗ |
2BH1900-2AK16 |
|
50/60 Hz, 220-240 V D / 380-420 V U |
Size 1, IE3 |
| 2BH1900-2AK26
p.2 ↗ |
2BH1900-2AK26 |
|
50/60 Hz, 220-240 V D / 380-420 V U |
Size 2, IE3 |
| 2BH1900-2AQ13
p.2 ↗ |
2BH1900-2AQ13 |
|
50/60 Hz, 500 V / 575 V |
Size 1 |
| 2BH1900-2AQ23
p.2 ↗ |
2BH1900-2AQ23 |
|
50/60 Hz, 500 V / 575 V |
Size 2 |
| 2BH1900-2AQ17
p.2 ↗ |
2BH1900-2AQ17 |
|
50/60 Hz, 380-420 V D / 660-725 V U |
Size 1 |
| 2BH1900-2AQ27
p.2 ↗ |
2BH1900-2AQ27 |
|
50/60 Hz, 380-420 V D / 660-725 V U |
Size 2 |