Technical Data Sheet — G-BH1 2BH1910 ATEX vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH1 910: soplador de canal lateral en configuración ATEX, serie G-BH1 N. Abarca las categorías ATEX 3GD y 3/2D como máquinas de tensión fija para 50 y 60 Hz; la categoría 3/2G disponible solo como versiones de 50 Hz o 60 Hz. Código de pedido 2BH1…-1.□.□-Z con campos de sustitución de tensión/frecuencia y ATEX.
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Rated pressure | 24,8 inch H2O p.2 ↗ | 2BH1 910, 50 Hz, 400 Δ/690 Y |
| Max. differential pressure vacuum | -145 inch H2O p.2 ↗ | 2BH1 910, 50 Hz, 400 Δ/690 Y |
| Max. differential pressure pressure | 161 inch H2O p.2 ↗ | 2BH1 910, 50 Hz, 400 Δ/690 Y |
| Voltage | 400 Δ/690 Y V p.2 ↗ | 2BH1 910, 50 Hz |
| Current | 32,0 Δ/18,6 Y A p.2 ↗ | 2BH1 910, 50 Hz, 400 Δ/690 Y |
| Power | 24,8 hp p.2 ↗ | 2BH1 910, 50 Hz |
| Sound pressure level | 72 dB(A) p.2 ↗ | 2BH1 910, 50 Hz |
| Weight approx. | 161 lbs p.2 ↗ | 2BH1 910, 50 Hz |
| Rated pressure | 28,6 inch H2O p.2 ↗ | 2BH1 910, 60 Hz, 460 Δ |
| Max. differential pressure vacuum | -149 inch H2O p.2 ↗ | 2BH1 910, 60 Hz, 460 Δ |
| Max. differential pressure pressure | 136 inch H2O p.2 ↗ | 2BH1 910, 60 Hz, 460 Δ |
| Voltage | 460 Δ V p.2 ↗ | 2BH1 910, 60 Hz |
| Current | 32,0 Δ A p.2 ↗ | 2BH1 910, 60 Hz, 460 Δ |
| Power | 28,6 hp p.2 ↗ | 2BH1 910, 60 Hz |
| Sound pressure level | 72 dB(A) p.2 ↗ | 2BH1 910, 60 Hz |
| Weight approx. | 136 lbs p.2 ↗ | 2BH1 910, 60 Hz |
Operating Limits
- ATEX category: 3GD and 3/2D (fixed voltage, 50 and 60 Hz); 3/2G only 50 Hz or 60 Hz p.1 ↗
- ATEX marking M74/75: II 3G IIB T3 Gc and II 3D T125°C Dc p.2 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Reference air temperature: 59 F p.1 ↗
- Reference atmospheric pressure: 29.92 inch Hg p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH1 | Series / type designation (side channel blower G-BH1 N) |
| field 1 p.2 ↗ | □ | Voltage connection code: D = Δ connection, G = Y connection |
| field 2 p.2 ↗ | □ | Voltage/frequency variant number: 1 = 230 Δ/400 Y (50 Hz) or 460 Y (60 Hz); 5 = 500 Δ (50 Hz) or 575 Δ (60 Hz); 6 = 400 Δ/690 Y (50 Hz) or 460 Δ (60 Hz) |
Modelos relacionados
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943