Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 2BH1930 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 930 soplador de canal lateral, tamaños n.º 1-4 (183, 199, 208, 218), 50 Hz y 60 Hz, variantes de tensión H (345-415 D / 600-720 Y; 380-480 D), C (500 Y; 575 Y), K, Q, y variantes de motor de tensión alternativa; números de pedido 2BH1930-1AH07, -1AH17, -1AH27, -1AH37, -1AC03, -1AC13, -1AC23, -1AC33.

Technical Data

Parameter Value Condición
Max. differential pressure vacuum -120 mbar p.2 ↗ 2BH1930 size 1, 50 Hz
Max. differential pressure pressure 110 mbar p.2 ↗ 2BH1930 size 1, 50 Hz
Voltage 345-415 D / 600-720 Y V p.2 ↗ 2BH1930 size 1, 50 Hz
Current 18,2 D / 10,5 Y A p.2 ↗ 2BH1930 size 1, 50 Hz
Power 8,5 kW p.2 ↗ 2BH1930 size 1, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1930 size 1, 50 Hz
Weight 183 kg p.2 ↗ 2BH1930 size 1, 50 Hz
Max. differential pressure vacuum -80 mbar p.2 ↗ 2BH1930 size 1, 60 Hz
Max. differential pressure pressure 70 mbar p.2 ↗ 2BH1930 size 1, 60 Hz
Voltage 380-480 D V p.2 ↗ 2BH1930 size 1, 60 Hz
Current 18,2 D A p.2 ↗ 2BH1930 size 1, 60 Hz
Power 9,8 kW p.2 ↗ 2BH1930 size 1, 60 Hz
Sound pressure level 75 dB(A) p.2 ↗ 2BH1930 size 1, 60 Hz
Weight 183 kg p.2 ↗ 2BH1930 size 1, 60 Hz
Max. differential pressure vacuum -320 mbar p.2 ↗ 2BH1930 size 4, 50 Hz
Max. differential pressure pressure 340 mbar p.2 ↗ 2BH1930 size 4, 50 Hz
Voltage 345-415 D / 600-720 Y V p.2 ↗ 2BH1930 size 4, 50 Hz
Current 37,0 D / 21,0 Y A p.2 ↗ 2BH1930 size 4, 50 Hz
Power 18,5 kW p.2 ↗ 2BH1930 size 4, 50 Hz
Sound pressure level 74 dB(A) p.2 ↗ 2BH1930 size 4, 50 Hz
Weight 218 kg p.2 ↗ 2BH1930 size 4, 50 Hz
Max. differential pressure vacuum -340 mbar p.2 ↗ 2BH1930 size 4, 60 Hz
Max. differential pressure pressure 320 mbar p.2 ↗ 2BH1930 size 4, 60 Hz
Power 21,3 kW p.2 ↗ 2BH1930 size 4, 60 Hz
Sound pressure level 78 dB(A) p.2 ↗ 2BH1930 size 4, 60 Hz

Operating Limits

  • Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Frequency tolerance: +/- 2 % maximum p.2 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Max. converter input voltage for standard motor insulation: 460 V p.2 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH1930 Type / size designation (side channel blower 2BH1 930)
8-9 p.2 ↗ -1 Version / series field

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH1930-1AH07 p.2 ↗ 2BH1930-1AH07 H Size 1, 50/60 Hz, 345-415 D / 600-720 Y (50 Hz), 380-480 D (60 Hz) Order number for suction port at blower cover: 2BH1930-1E□□□
2BH1930-1AH17 p.2 ↗ 2BH1930-1AH17 H Size 2, 50/60 Hz, 345-415 D / 600-720 Y (50 Hz), 380-480 D (60 Hz)
2BH1930-1AH27 p.2 ↗ 2BH1930-1AH27 H Size 3, 50/60 Hz, 345-415 D / 600-720 Y (50 Hz), 380-480 D (60 Hz)
2BH1930-1AH37 p.2 ↗ 2BH1930-1AH37 H Size 4, 50/60 Hz, 345-415 D / 600-720 Y (50 Hz), 380-480 D (60 Hz)
2BH1930-1AC03 p.2 ↗ 2BH1930-1AC03 C Size 1, 50/60 Hz, 500 Y (50 Hz), 575 Y (60 Hz)
2BH1930-1AC13 p.2 ↗ 2BH1930-1AC13 C Size 2, 50/60 Hz, 500 Y (50 Hz), 575 Y (60 Hz)
2BH1930-1AC23 p.2 ↗ 2BH1930-1AC23 C Size 3, 50/60 Hz, 500 Y (50 Hz), 575 Y (60 Hz)
2BH1930-1AC33 p.2 ↗ 2BH1930-1AC33 C Size 4, 50/60 Hz, 500 Y (50 Hz), 575 Y (60 Hz)