Technical Data Sheet — G-BH2 2BH20360-1 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH2 0360-1: soplador de canal lateral VELOCIS G-BH2 e con convertidor de frecuencia. Abarca los tamaños 1, 2, 3 (2BH20360-1AA3K6-BA, -1AA3L6-BA, -1AA3M6-BA) y las variantes de 60 Hz (2BH20360-1AAKK6-BA, -1AAKL6-BA, -1AAKM6-BA), además de los tipos de VFD 2FC4152-1 a 2FC4223-1 y accesorios.
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Rated frequency | 87 Hz p.2 ↗ | size 1, 2BH20360-1AA3K6-BA |
| Rated voltage | 380 V p.2 ↗ | size 1, 2BH20360-1AA3K6-BA |
| Rated current | 11.5 A p.2 ↗ | size 1, 2BH20360-1AA3K6-BA |
| Rated power | 5.8 kW p.2 ↗ | size 1, 2BH20360-1AA3K6-BA |
| Max. differential pressure vacuum | -180 mbar p.2 ↗ | size 1, 2BH20360-1AA3K6-BA |
| Max. differential pressure pressure | 130 mbar p.2 ↗ | size 1, 2BH20360-1AA3K6-BA |
| Sound pressure level | 78 dB(A) p.2 ↗ | size 1, 2BH20360-1AA3K6-BA |
| Weight | 75/76 kg p.2 ↗ | size 1, 2BH20360-1AA3K6-BA |
| Rated frequency | 85 Hz p.2 ↗ | size 2, 2BH20360-1AA3L6-BA |
| Rated voltage | 380 V p.2 ↗ | size 2, 2BH20360-1AA3L6-BA |
| Rated current | 14.9 A p.2 ↗ | size 2, 2BH20360-1AA3L6-BA |
| Rated power | 7.5 kW p.2 ↗ | size 2, 2BH20360-1AA3L6-BA |
| Max. differential pressure vacuum | -400 mbar p.2 ↗ | size 2, 2BH20360-1AA3L6-BA |
| Max. differential pressure pressure | 300 mbar p.2 ↗ | size 2, 2BH20360-1AA3L6-BA |
| Sound pressure level | 78 dB(A) p.2 ↗ | size 2, 2BH20360-1AA3L6-BA |
| Weight | 75/76 kg p.2 ↗ | size 2, 2BH20360-1AA3L6-BA |
| Rated frequency | 85 Hz p.2 ↗ | size 3, 2BH20360-1AA3M6-BA |
| Rated voltage | 380 V p.2 ↗ | size 3, 2BH20360-1AA3M6-BA |
| Rated current | 10.2 A p.2 ↗ | size 3, 2BH20360-1AA3M6-BA |
| Rated power | 10.2 kW p.2 ↗ | size 3, 2BH20360-1AA3M6-BA |
| Max. differential pressure vacuum | -450 mbar p.2 ↗ | size 3, 2BH20360-1AA3M6-BA |
| Max. differential pressure pressure | 500 mbar p.2 ↗ | size 3, 2BH20360-1AA3M6-BA |
| Sound pressure level | 84 dB(A) p.2 ↗ | size 3, 2BH20360-1AA3M6-BA |
| Weight | 75/76 kg p.2 ↗ | size 3, 2BH20360-1AA3M6-BA |
Operating Limits
- Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
- Performance curve reference air temperature: 15 °C p.1 ↗
- Performance curve reference atmospheric pressure: 1013 mbar p.1 ↗
- Performance tolerance: ±10 % p.1 ↗
- Minimum pulse frequency of frequency converter: 4 kHz p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-9 p.2 ↗ | 2BH20360- | Type designation / size (2BH2 0360-1) |
| 10-12 p.2 ↗ | 1AA | Motor / voltage variant field |
| 16-17 p.2 ↗ | BA | Version suffix |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Aplica a | Note |
|---|---|---|---|---|
| 2BH20360-1AA3K6-BA p.2 ↗ | 2BH20360-1AA3K6-BA | size 1, 87 Hz, 380 V | Standard version | |
| 2BH20360-1AA3L6-BA p.2 ↗ | 2BH20360-1AA3L6-BA | size 2, 85 Hz, 380 V | Standard version | |
| 2BH20360-1AA3M6-BA p.2 ↗ | 2BH20360-1AA3M6-BA | size 3, 85 Hz, 380 V | Standard version | |
| 2BH20360-1AAKK6-BA p.2 ↗ | 2BH20360-1AAKK6-BA | size 1, 60 Hz | 60 Hz variant | |
| 2BH20360-1AAKL6-BA p.2 ↗ | 2BH20360-1AAKL6-BA | size 2, 60 Hz | 60 Hz variant | |
| 2BH20360-1AAKM6-BA p.2 ↗ | 2BH20360-1AAKM6-BA | size 3, 60 Hz | 60 Hz variant |