Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH2 2BH20360-1 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH2 0360-1: soplador de canal lateral VELOCIS G-BH2 e con convertidor de frecuencia. Abarca los tamaños 1, 2, 3 (2BH20360-1AA3K6-BA, -1AA3L6-BA, -1AA3M6-BA) y las variantes de 60 Hz (2BH20360-1AAKK6-BA, -1AAKL6-BA, -1AAKM6-BA), además de los tipos de VFD 2FC4152-1 a 2FC4223-1 y accesorios.

Technical Data

Parameter Value Condición
Rated frequency 87 Hz p.2 ↗ size 1, 2BH20360-1AA3K6-BA
Rated voltage 380 V p.2 ↗ size 1, 2BH20360-1AA3K6-BA
Rated current 11.5 A p.2 ↗ size 1, 2BH20360-1AA3K6-BA
Rated power 5.8 kW p.2 ↗ size 1, 2BH20360-1AA3K6-BA
Max. differential pressure vacuum -180 mbar p.2 ↗ size 1, 2BH20360-1AA3K6-BA
Max. differential pressure pressure 130 mbar p.2 ↗ size 1, 2BH20360-1AA3K6-BA
Sound pressure level 78 dB(A) p.2 ↗ size 1, 2BH20360-1AA3K6-BA
Weight 75/76 kg p.2 ↗ size 1, 2BH20360-1AA3K6-BA
Rated frequency 85 Hz p.2 ↗ size 2, 2BH20360-1AA3L6-BA
Rated voltage 380 V p.2 ↗ size 2, 2BH20360-1AA3L6-BA
Rated current 14.9 A p.2 ↗ size 2, 2BH20360-1AA3L6-BA
Rated power 7.5 kW p.2 ↗ size 2, 2BH20360-1AA3L6-BA
Max. differential pressure vacuum -400 mbar p.2 ↗ size 2, 2BH20360-1AA3L6-BA
Max. differential pressure pressure 300 mbar p.2 ↗ size 2, 2BH20360-1AA3L6-BA
Sound pressure level 78 dB(A) p.2 ↗ size 2, 2BH20360-1AA3L6-BA
Weight 75/76 kg p.2 ↗ size 2, 2BH20360-1AA3L6-BA
Rated frequency 85 Hz p.2 ↗ size 3, 2BH20360-1AA3M6-BA
Rated voltage 380 V p.2 ↗ size 3, 2BH20360-1AA3M6-BA
Rated current 10.2 A p.2 ↗ size 3, 2BH20360-1AA3M6-BA
Rated power 10.2 kW p.2 ↗ size 3, 2BH20360-1AA3M6-BA
Max. differential pressure vacuum -450 mbar p.2 ↗ size 3, 2BH20360-1AA3M6-BA
Max. differential pressure pressure 500 mbar p.2 ↗ size 3, 2BH20360-1AA3M6-BA
Sound pressure level 84 dB(A) p.2 ↗ size 3, 2BH20360-1AA3M6-BA
Weight 75/76 kg p.2 ↗ size 3, 2BH20360-1AA3M6-BA

Operating Limits

  • Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve reference air temperature: 15 °C p.1 ↗
  • Performance curve reference atmospheric pressure: 1013 mbar p.1 ↗
  • Performance tolerance: ±10 % p.1 ↗
  • Minimum pulse frequency of frequency converter: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗

Type Code Decoder

Position Token Meaning
1-9 p.2 ↗ 2BH20360- Type designation / size (2BH2 0360-1)
10-12 p.2 ↗ 1AA Motor / voltage variant field
16-17 p.2 ↗ BA Version suffix

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH20360-1AA3K6-BA p.2 ↗ 2BH20360-1AA3K6-BA size 1, 87 Hz, 380 V Standard version
2BH20360-1AA3L6-BA p.2 ↗ 2BH20360-1AA3L6-BA size 2, 85 Hz, 380 V Standard version
2BH20360-1AA3M6-BA p.2 ↗ 2BH20360-1AA3M6-BA size 3, 85 Hz, 380 V Standard version
2BH20360-1AAKK6-BA p.2 ↗ 2BH20360-1AAKK6-BA size 1, 60 Hz 60 Hz variant
2BH20360-1AAKL6-BA p.2 ↗ 2BH20360-1AAKL6-BA size 2, 60 Hz 60 Hz variant
2BH20360-1AAKM6-BA p.2 ↗ 2BH20360-1AAKM6-BA size 3, 60 Hz 60 Hz variant