Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH2 2BH20540-1 ATEX vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH2 0540-1: soplador de canal lateral en configuración ATEX, serie G-BH2 N, categorías ATEX 3GD y 3/2D como máquinas de tensión fija para 50 y 60 Hz; 3/2G disponible solo como versiones de 50 Hz o 60 Hz. Código de pedido 2BH20540-1AADN1-BA-Z con Z=M74.

Technical Data

Parameter Value Condición
Rated voltage 230 ∆/ 400 Y V p.2 ↗ 2BH20540-1, 50 Hz
Rated current 22,5 ∆/ 13,1 Y A p.2 ↗ 2BH20540-1, 50 Hz
Rated power 7,5 kW p.2 ↗ 2BH20540-1, 50 Hz
Max. differential pressure (vacuum) -300 mbar p.2 ↗ 2BH20540-1, 50 Hz
Max. differential pressure (pressure) 410 mbar p.2 ↗ 2BH20540-1, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH20540-1, 50 Hz
Weight 103 kg p.2 ↗ 2BH20540-1, 50 Hz
Degree of protection IP55 p.2 ↗ 2BH20540-1
ATEX category 3GD p.2 ↗ 2BH20540-1
Rated voltage 460 Y V p.2 ↗ 2BH20540-1, 60 Hz
Rated current 13,0 Y A p.2 ↗ 2BH20540-1, 60 Hz
Rated power 8,6 kW p.2 ↗ 2BH20540-1, 60 Hz
Max. differential pressure (vacuum) -310 mbar p.2 ↗ 2BH20540-1, 60 Hz
Max. differential pressure (pressure) 420 mbar p.2 ↗ 2BH20540-1, 60 Hz
Sound pressure level 75 dB(A) p.2 ↗ 2BH20540-1, 60 Hz
Weight 103 kg p.2 ↗ 2BH20540-1, 60 Hz
Motor thermal class F p.2 ↗
Motor efficiency class IE3 p.2 ↗
Frequency tolerance +/- 2 % p.2 ↗

Operating Limits

  • Max. suction and ambient temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Frequency tolerance: +/- 2 % p.2 ↗
  • Degree of protection: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH2 Series / type: side channel blower G-BH2 N
5-8 p.2 ↗ 0540 Size designation
9-10 p.2 ↗ -1 Variant / stage designation
11-15 p.2 ↗ AADN1 Motor / ATEX configuration code
16-17 p.2 ↗ -BA Design / connection variant
Z= (voltage field) p.2 ↗ D1 Voltage variant: 230 ∆ / 400 Y, 50 Hz
Z= (voltage field) p.2 ↗ D6 Voltage variant: 400 ∆ / 690 Y, 50 Hz
Z= (voltage field) p.2 ↗ D5 Voltage variant: 500 ∆ / 575 ∆, 50 Hz