Technical Data Sheet — G-BH2 2BH20540-1 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH2 0540-1: soplador de canal lateral con convertidor de frecuencia integrado (VFD), 3~ 400 V -15%…480 V +10%, 50/60 Hz ±6%, IP55, clase de aislamiento F, UL 1450 / CAN/CSA C22.2 No. 68-09. Las variantes difieren en potencia/corriente nominal y tipo de VFD (G, A, F).
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Rated frequency | 50/60 Hz p.2 ↗ | 2BH2 0540-1 |
| Rated voltage | 380 V p.2 ↗ | 2BH20540-1AA3M6-BA, 85 Hz, Y |
| Rated voltage | 400 V p.2 ↗ | 2BH20540-1AA3N6-BA, 85 Hz, Δ |
| Current | 20.3 A p.2 ↗ | 2BH20540-1AA3M6-BA, 85 Hz, Y |
| Current | 27.4 A p.2 ↗ | 2BH20540-1AA3N6-BA, 85 Hz |
| Current | 14.5 A p.2 ↗ | 2BH20540-1AAKL6-BA, 72 Hz, Δ |
| Power | 10.2 kW p.2 ↗ | 2BH20540-1AA3M6-BA, 85 Hz |
| Power | 14.0 kW p.2 ↗ | 2BH20540-1AA3N6-BA, 85 Hz |
| Power | 7.5 kW p.2 ↗ | 2BH20540-1AAKL6-BA, 72 Hz |
| Max. differential pressure, vacuum | -220 mbar p.2 ↗ | 2BH20540-1AA3M6-BA, 85 Hz |
| Max. differential pressure, pressure | 140 mbar p.2 ↗ | 2BH20540-1AA3M6-BA, 85 Hz |
| Max. differential pressure, vacuum | -420 mbar p.2 ↗ | 2BH20540-1AA3N6-BA, 85 Hz |
| Max. differential pressure, pressure | 330 mbar p.2 ↗ | 2BH20540-1AA3N6-BA, 85 Hz |
| Max. differential pressure, vacuum | -100 mbar p.2 ↗ | 2BH20540-1AAKL6-BA, 72 Hz |
| Max. differential pressure, pressure | 80 mbar p.2 ↗ | 2BH20540-1AAKL6-BA, 72 Hz |
| Sound pressure level | 84 dB(A) p.2 ↗ | 2BH20540-1AA3M6-BA, 85 Hz |
| Sound pressure level | 84 dB(A) p.2 ↗ | 2BH20540-1AA3N6-BA, 85 Hz |
| Sound pressure level | 75 dB(A) p.2 ↗ | 2BH20540-1AAKL6-BA, 72 Hz |
| Weight | 91 kg p.2 ↗ | 2BH20540-1AA3M6-BA |
| Weight | 123 kg p.2 ↗ | 2BH20540-1AA3N6-BA |
| Weight | 83 kg p.2 ↗ | 2BH20540-1AAKL6-BA |
| Protection class | IP55 p.2 ↗ | integrated VFD |
| Insulation material class | F p.2 ↗ | motor |
| Rated voltage/frequency set point | 345 V / 87 Hz p.1 ↗ | delta connection of motor |
| Minimum pulse frequency | 4 kHz p.1 ↗ | frequency converter operation |
Operating Limits
- Suction and ambient temperature for stated total pressure differences: up to 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Frequency tolerance: +/- 2 % maximum p.2 ↗
- Mains voltage for frequency converter: 380 V minimum p.1 ↗
- Protection class: IP55 p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-8 p.2 ↗ | 2BH20540 | Type/size designation (side channel blower 2BH2, size 0540) |
| 10-12 p.2 ↗ | 1AA | Motor/design variant field |
| 17-18 p.2 ↗ | BA | Suffix variant field |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Aplica a | Note |
|---|---|---|---|---|
| 2BH20540-1AA3M6-BA p.2 ↗ | 2BH20540-1AA3M6-BA | G | 85 Hz, 380 V Y, 20.3 A, 10.2 kW | VFD type G |
| 2BH20540-1AA3N6-BA p.2 ↗ | 2BH20540-1AA3N6-BA | G | 85 Hz, 380 V, 27.4 A, 14.0 kW | VFD type G |
| 2BH20540-1AAKL6-BA p.2 ↗ | 2BH20540-1AAKL6-BA | F | 72 Hz, 330 V Δ, 14.5 A, 7.5 kW | VFD type F |
| 2BH20540-1AAKM6-BA p.2 ↗ | 2BH20540-1AAKM6-BA | G | 85 Hz, 400 V Δ, 20.4 A, 10.2 kW | VFD type G |
| 2BH20540-1AAKN6-BA p.2 ↗ | 2BH20540-1AAKN6-BA | G | 85 Hz, 400 V Δ, 26.0 A, 14.0 kW | VFD type G |