Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH2 2BH20540-3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH2 0540-3: soplador de canal lateral con convertidor de frecuencia integrado (VFD), tipo 2BH2 0540-3, variantes 2BH20540-3AA3P6-BA (20.5 kW) y 2BH20540-3AA3Q6-BA (25.0 kW), 380 V Y / 400 V Δ, 85 Hz, con VFD integrado 3~ 400 V -15%…480 V +10%, 50/60 Hz ±6%, IP55, UL 1450; también enumera convertidores de frecuencia externos correspondientes 2FC4… y accesorios.

Technical Data

Parameter Value Condición
Rated frequency 85 Hz p.2 ↗ 2BH2 0540-3
Voltage 380 V p.2 ↗ 2BH2 0540-3, Y connection
Voltage 400 V p.2 ↗ 2BH2 0540-3, Δ connection
Current 41.0 A p.2 ↗ 2BH2 0540-3, 380 V Y, 20.5 kW
Current 48.0 A p.2 ↗ 2BH2 0540-3, 380 V Y, 25.0 kW
Current 39.5 A p.2 ↗ 2BH2 0540-3, 400 V Δ, 20.5 kW
Current 53.7 A p.2 ↗ 2BH2 0540-3, 400 V Δ, 28.8 kW
Current 65.3 A p.2 ↗ 2BH2 0540-3, 400 V, 35.5 kW
Power 20.5 kW p.2 ↗ 2BH2 0540-3, 380 V Y
Power 25.0 kW p.2 ↗ 2BH2 0540-3, 380 V Y
Power 20.5 kW p.2 ↗ 2BH2 0540-3, 400 V Δ
Power 28.8 kW p.2 ↗ 2BH2 0540-3, 400 V Δ
Power 35.5 kW p.2 ↗ 2BH2 0540-3, 400 V
Max. differential pressure vacuum -500 mbar p.2 ↗ 2BH2 0540-3, 85 Hz
Max. differential pressure pressure 130 mbar p.2 ↗ 2BH2 0540-3, 20.5 kW, 85 Hz
Max. differential pressure pressure 350 mbar p.2 ↗ 2BH2 0540-3, 25.0 kW, 85 Hz
Max. differential pressure pressure 520 mbar p.2 ↗ 2BH2 0540-3, 400 V Δ, 28.8 kW, 85 Hz
Max. differential pressure pressure 730 mbar p.2 ↗ 2BH2 0540-3, 400 V, 35.5 kW, 85 Hz
Sound pressure level 79/80 dB(A) p.2 ↗ 2BH2 0540-3, 50 Hz / 60 Hz
Weight 180 kg p.2 ↗ 2BH2 0540-3, 20.5 kW
Weight 182 kg p.2 ↗ 2BH2 0540-3, 25.0 kW
Protection class IP55 p.2 ↗ 2BH2 0540-3, integrated VFD
Insulation material class F p.2 ↗ 2BH2 0540-3
Rated mains voltage (VFD) 3~ 400 V -15% … 480 V +10% V p.2 ↗ Integrated VFD
Mains frequency (VFD) 50/60 Hz p.2 ↗ Integrated VFD, ±6%

Operating Limits

  • Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve reference air temperature: 15 °C p.1 ↗
  • Performance curve reference atmospheric pressure: 1013 mbar p.1 ↗
  • Performance tolerance: ±10 % p.1 ↗
  • Minimum pulse frequency of frequency converter: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH2 Series: side channel blower G-BH2
5-8 p.2 ↗ 0540 Size
9-10 p.2 ↗ -3 Version
11-13 p.2 ↗ AA3 Motor / connection variant
16-17 p.2 ↗ -BA Execution suffix
VFD type field p.2 ↗ 2FC4152-1 □ □00 … 2FC4223-1 □ □00 External frequency converter type; □ = option field

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH20540-3AA3P6-BA p.2 ↗ 2BH20540-3AA3P6-BA 380 V Y, 85 Hz, 20.5 kW Integrated VFD
2BH20540-3AA3Q6-BA p.2 ↗ 2BH20540-3AA3Q6-BA 380 V Y, 85 Hz, 25.0 kW Integrated VFD
2BH20540-3AAKP6-BA p.2 ↗ 2BH20540-3AAKP6-BA 380 V Y, 85 Hz, 20.5 kW Integrated VFD, footnote 3