Technical Data Sheet — G-BH7 2BH7410 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH7 410 (serie G-BH7 e): soplante de canal lateral con convertidor de frecuencia integrado, variantes 2BH7410-0A3xx-1 (100 Hz, 400 V) y 2BH7410-0A3x6-1 (87 Hz, 380 V), además de variantes 2BH7410-0AKx6-1 para funcionamiento con convertidor de frecuencia externo (37/50/60 Hz); convertidores de frecuencia correspondientes 2FC4xxx-1□□00 (tamaños A–K) y accesorios (terminal portátil MMI, cable adaptador USB, sensores de presión/vacío).
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Rated frequency | 100 Hz p.2 ↗ | 2BH7410-0A311-1 |
| Rated voltage | 400 V p.2 ↗ | 2BH7410-0A311-1 |
| Rated current | 5,2 A p.2 ↗ | 2BH7410-0A311-1 |
| Rated motor power | 2,6 kW p.2 ↗ | 2BH7410-0A311-1 |
| Max. differential pressure, vacuum | -230 mbar p.2 ↗ | 2BH7410-0A311-1 |
| Max. differential pressure, pressure | 220 mbar p.2 ↗ | 2BH7410-0A311-1 |
| Sound pressure level | 73 dB(A) p.2 ↗ | 2BH7410-0A311-1 |
| Weight | 33 kg p.2 ↗ | 2BH7410-0A311-1 |
| Rated current | 6,5 A p.2 ↗ | 2BH7410-0A321-1 |
| Rated motor power | 3,5 kW p.2 ↗ | 2BH7410-0A321-1 |
| Max. differential pressure, vacuum | -390 mbar p.2 ↗ | 2BH7410-0A321-1 |
| Max. differential pressure, pressure | 380 mbar p.2 ↗ | 2BH7410-0A321-1 |
| Sound pressure level | 77 dB(A) p.2 ↗ | 2BH7410-0A321-1 |
| Weight | 36 kg p.2 ↗ | 2BH7410-0A321-1 |
| Rated current | 9,5 A p.2 ↗ | 2BH7410-0A331-1 |
| Rated motor power | 5,0 kW p.2 ↗ | 2BH7410-0A331-1 |
| Max. differential pressure, vacuum | -410 mbar p.2 ↗ | 2BH7410-0A331-1 |
| Max. differential pressure, pressure | 650 mbar p.2 ↗ | 2BH7410-0A331-1 |
| Sound pressure level | 77 dB(A) p.2 ↗ | 2BH7410-0A331-1 |
| Weight | 41 kg p.2 ↗ | 2BH7410-0A331-1 |
| Rated frequency | 87 Hz p.2 ↗ | 2BH7410-0A316-1 |
| Rated voltage | 380 V p.2 ↗ | 2BH7410-0A316-1 |
| Rated current | 4,8 A p.2 ↗ | 2BH7410-0A316-1 |
| Rated motor power | 2,3 kW p.2 ↗ | 2BH7410-0A316-1 |
| Max. differential pressure, vacuum | -360 mbar p.2 ↗ | 2BH7410-0A316-1 |
Operating Limits
- Max. suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Reference air temperature for performance curves: 15 °C p.1 ↗
- Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗
- Minimum pulse frequency for frequency converter operation: 4 kHz p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-7 p.2 ↗ | 2BH7410 | Type/size designation: side channel blower 2BH7, size 410 |
| 8-9 p.2 ↗ | 0A | Series/variant prefix |
| 13-14 p.2 ↗ | -1 | Design/revision suffix |
| converter field p.2 ↗ | 2FC4xxx-1□□00 | Frequency converter order code; □□ = voltage/connection option field |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Aplica a | Note |
|---|---|---|---|---|
| 2BH7410-0A311-1 p.2 ↗ | 2BH7410-0A311-1 | B | 100 Hz, 400 V | 2.6 kW, 33 kg |
| 2BH7410-0A321-1 p.2 ↗ | 2BH7410-0A321-1 | C | 100 Hz, 400 V | 3.5 kW, 36 kg |
| 2BH7410-0A331-1 p.2 ↗ | 2BH7410-0A331-1 | D | 100 Hz, 400 V | 5.0 kW, 41 kg |
| 2BH7410-0A316-1 p.2 ↗ | 2BH7410-0A316-1 | B | 87 Hz, 380 V | 2.3 kW, 33 kg |
| 2BH7410-0A326-1 p.2 ↗ | 2BH7410-0A326-1 | C | 87 Hz, 380 V | 2.9 kW, 36 kg |
| 2BH7410-0A336-1 p.2 ↗ | 2BH7410-0A336-1 | D | 87 Hz, 380 V | 4.3 kW, 41 kg |
| 2BH7410-0AK16-1 p.2 ↗ | 2BH7410-0AK16-1 | external converter, 37/50/60 Hz | 2.3 kW, 28 kg | |
| 2BH7410-0AK26-1 p.2 ↗ | 2BH7410-0AK26-1 | external converter, 37/50/60 Hz | 2.9 kW, 31 kg | |
| 2BH7410-0AK36-1 p.2 ↗ | 2BH7410-0AK36-1 | external converter, 37/50/60 Hz | 4.3 kW, 36 kg |