Technical Data Sheet — 2BH742 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH7 420, soplador de canal lateral con motores IE3, tipo 2BH7 420, tamaños 1/2/3, 3~ 50/60 Hz, IP55, clase de aislamiento F, UL 1450 y CAN/CSA C22.2 No. 68-09 (número de certificado E225239); variantes de tensión 190-210 Δ, 220-240 Δ/380-420 Y, 500 Y, 380-420 Δ/660-725 Y, variantes de 60 Hz 190-210/380-420, 200, 220-240/440-480, 230/460, 575, 440-480 Δ, 460 Δ
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Rated voltage | 190-210 V p.2 ↗ | 2BH7420-0AK21-1, 50 Hz, Δ |
| Current | 6,9 A p.2 ↗ | 2BH7420-0AK21-1, 50 Hz, Δ |
| Power | 1,8 kW p.2 ↗ | 2BH7420-0AK21-1, 50 Hz |
| Max. differential pressure vacuum | -500 mbar p.2 ↗ | 2BH7420-0AK21-1, 50 Hz |
| Max. differential pressure pressure | 460 mbar p.2 ↗ | 2BH7420-0AK21-1, 50 Hz |
| Sound pressure level | 64 dB(A) p.2 ↗ | 2BH7420-0AK21-1, 50 Hz |
| Weight | 38 kg p.2 ↗ | 2BH7420-0AK21-1 |
| Rated voltage | 190-210/380-420 V p.2 ↗ | 2BH7420-0AK21-1, 60 Hz, Δ/Y |
| Current | 7,8/3,9 A p.2 ↗ | 2BH7420-0AK21-1, 60 Hz, Δ/Y |
| Power | 2,0 kW p.2 ↗ | 2BH7420-0AK21-1, 60 Hz |
| Max. differential pressure vacuum | -500 mbar p.2 ↗ | 2BH7420-0AK21-1, 60 Hz |
| Max. differential pressure pressure | 410 mbar p.2 ↗ | 2BH7420-0AK21-1, 60 Hz |
| Sound pressure level | 67 dB(A) p.2 ↗ | 2BH7420-0AK21-1, 60 Hz |
| Rated voltage | 190-210 V p.2 ↗ | 2BH7420-0AK31-1, 50 Hz, Δ |
| Current | 9,9 A p.2 ↗ | 2BH7420-0AK31-1, 50 Hz, Δ |
| Power | 2,5 kW p.2 ↗ | 2BH7420-0AK31-1, 50 Hz |
| Max. differential pressure vacuum | -500 mbar p.2 ↗ | 2BH7420-0AK31-1, 50 Hz |
| Max. differential pressure pressure | 730 mbar p.2 ↗ | 2BH7420-0AK31-1, 50 Hz |
| Sound pressure level | 64 dB(A) p.2 ↗ | 2BH7420-0AK31-1, 50 Hz |
| Weight | 43 kg p.2 ↗ | 2BH7420-0AK31-1 |
| Rated voltage | 190-210 V p.2 ↗ | 2BH7420-0AK61-1, 50 Hz, Δ |
| Current | 13,3 A p.2 ↗ | 2BH7420-0AK61-1, 50 Hz, Δ |
| Power | 3,45 kW p.2 ↗ | 2BH7420-0AK61-1, 50 Hz |
| Max. differential pressure vacuum | -500 mbar p.2 ↗ | 2BH7420-0AK61-1, 50 Hz |
| Max. differential pressure pressure | 830 mbar p.2 ↗ | 2BH7420-0AK61-1, 50 Hz |
Operating Limits
- Max. ambient/suction temperature for stated total pressure differences: 25 °C p.1 ↗
- Protection category: IP 55 p.1 ↗
- Insulation class: F p.1 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
- Reference air temperature for performance curves: 15 °C p.1 ↗
- Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH7 | Series G-BH 7 side channel blower |
| 5-7 p.2 ↗ | 420 | Size 420 |
| field 1 p.2 ↗ | 0AK / 0AQ | Voltage/motor variant group |
| field 2 p.2 ↗ | 2 / 3 / 6 | Performance size 1 / 2 / 3 |
| field 3 p.2 ↗ | 1 / 6 / 7 | Voltage code (1: 190-210 Δ; 6: 220-240 Δ/380-420 Y; 7: 380-420 Δ/660-725 Y) |
| suffix p.2 ↗ | -1 | Standard version |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Aplica a | Note |
|---|---|---|---|---|
| 2BH7420-0AK21-1 p.2 ↗ | 2BH7420-0AK21-1 | 50/60 Hz, 190-210 Δ / 190-210/380-420 Δ/Y | Size 1, 1,8/2,0 kW | |
| 2BH7420-0AK31-1 p.2 ↗ | 2BH7420-0AK31-1 | 50/60 Hz, 190-210 Δ / 190-210/380-420 Δ/Y | Size 2, 2,5/3,0 kW | |
| 2BH7420-0AK61-1 p.2 ↗ | 2BH7420-0AK61-1 | 50/60 Hz, 190-210 Δ / 190-210/380-420 Δ/Y | Size 3, 3,45/4,0 kW | |
| 2BH7420-0AK26-1 p.2 ↗ | 2BH7420-0AK26-1 | 50/60 Hz, 220-240 Δ/380-420 Y / 220-240/440-480 Δ/Y | Size 1, 1,8/2,0 kW | |
| 2BH7420-0AK36-1 p.2 ↗ | 2BH7420-0AK36-1 | 50/60 Hz, 220-240 Δ/380-420 Y / 220-240/440-480 Δ/Y | Size 2, 2,5/3,0 kW | |
| 2BH7420-0AK66-1 p.2 ↗ | 2BH7420-0AK66-1 | 50/60 Hz, 220-240 Δ/380-420 Y / 220-240/440-480 Δ/Y | Size 3, 3,45/4,0 kW | |
| 2BH7420-0AQ23-1 p.2 ↗ | 2BH7420-0AQ23-1 | 50/60 Hz, 500 Y / 575 Y | Size 1, 1,8/2,0 kW | |
| 2BH7420-0AQ33-1 p.2 ↗ | 2BH7420-0AQ33-1 | 50/60 Hz, 500 Y / 575 Y | Size 2, 2,5/3,0 kW | |
| 2BH7420-0AQ63-1 p.2 ↗ | 2BH7420-0AQ63-1 | 50/60 Hz, 500 Y / 575 Y | Size 3, 3,45/4,0 kW | |
| 2BH7420-0AQ27-1 p.2 ↗ | 2BH7420-0AQ27-1 | 50/60 Hz, 380-420 Δ/660-725 Y / 440-480 Δ | Size 1, 1,8/2,0 kW |