Technical Reference Summary
Covered Models & Document Scope
Gama de bombas de vacío de anillo líquido modelo L-BV7, hoja de datos para el tamaño 2BV7 071. Abarca variantes de tensión de 50 Hz y 60 Hz (190-210 V, 220-240 V, 380-420 V, 440-480 V, 460 V, 500 V, 575 V, 660-725 V, 690 V) con motores de eficiencia IE3 o NP; carcasa/placa de puertos de acero CrNi, impulsor de bronce, linterna de fundición.
Technical Data
| Parameter |
Value |
Condición |
| Ultimate pressure |
33 mbar abs.
p.1 ↗ |
2BV7 071 |
| Cavitation-free operation down to |
80 mbar abs.
p.1 ↗ |
2BV7 071 |
| Suction capacity |
72 m³/h
p.2 ↗ |
2BV7 071, 50 Hz, 3.4 kW |
| Suction capacity |
78 m³/h
p.2 ↗ |
2BV7 071, 50 Hz, 4.6 kW |
| Motor power |
3,4 kW
p.2 ↗ |
2BV7 071, 50 Hz, IE3 |
| Motor power |
4,6 kW
p.2 ↗ |
2BV7 071, 50 Hz, IE3/NP |
| Voltage |
190-210 V
p.2 ↗ |
2BV7 071, 50 Hz, Δ |
| Voltage |
380-420 V
p.2 ↗ |
2BV7 071, 50 Hz, Y |
| Voltage |
220-240 V
p.2 ↗ |
2BV7 071, 50 Hz, Δ |
| Voltage |
440-480 V
p.2 ↗ |
2BV7 071, 50 Hz, Y |
| Voltage |
500 V
p.2 ↗ |
2BV7 071, 50 Hz, Y |
| Voltage |
575 V
p.2 ↗ |
2BV7 071, 60 Hz, Y |
| Current |
20,8 A
p.2 ↗ |
2BV7 071, 50 Hz, 190-210 V Δ, 3.4 kW |
| Current |
11,7 A
p.2 ↗ |
2BV7 071, 50 Hz, 380-420 V Y, 4.6 kW |
| Current |
17,8 A
p.2 ↗ |
2BV7 071, 50 Hz, 220-240 V Δ, 3.4 kW |
| Current |
10,3 A
p.2 ↗ |
2BV7 071, 50 Hz, 380-420 V Y, 3.4 kW |
| Service factor |
1,62
p.2 ↗ |
2BV7 071, 3.4 kW |
| Service factor |
1,37
p.2 ↗ |
2BV7 071, 4.6 kW IE3 |
| Service factor |
1,20
p.2 ↗ |
2BV7 071, 4.6 kW NP |
| Operating liquid level |
0,35
p.2 ↗ |
2BV7 071, 3.4 kW |
| Operating liquid level |
0,38
p.2 ↗ |
2BV7 071, 4.6 kW |
| Noise level |
72 dB(A)
p.2 ↗ |
2BV7 071, 3.4 kW |
| Noise level |
78 dB(A)
p.2 ↗ |
2BV7 071, 4.6 kW |
| Weight |
55 kg
p.2 ↗ |
2BV7 071, 3.4 kW |
| Protection rating |
IP55
p.1 ↗ |
standard motor |
Operating Limits
- Minimum inlet pressure (ultimate vacuum): 33 mbar abs.
p.1 ↗
- Cavitation-free operation down to: 80 mbar abs.
p.1 ↗
- Max. additional water carry-over: 1,35 m³/h
p.2 ↗
- Max. back pressure: 1300 mbar atm.
p.2 ↗
- Protection rating: IP55
p.1 ↗
Type Code Decoder
| Position |
Token |
Meaning |
| 1-7
p.2 ↗ |
2BV7071 |
Model range and size (L-BV7, size 071) |
| 8-9
p.2 ↗ |
-2 |
Design variant |
| field 3
p.2 ↗ |
□ |
Voltage/frequency variant code: K = 50/60 Hz 190-210 V / 380-420 V; Q = 50/60 Hz 380-420 V / 660-725 V; 6 = 50/60 Hz 220-240 V / 440-480 V |
| field 4
p.2 ↗ |
K00 / Q00 |
Voltage range group (K00, Q00) |
| field 5
p.2 ↗ |
1B / 6B / 7B |
Voltage/frequency option suffix (1B, 6B, 7B) |