Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 BH1023-6 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Soplador de canal lateral G-BH1, hoja de datos BH1023-6 (2BH1530), motor monofásico (1~). Variantes: BH1023-6AAA-HV5-BA0 (rango de tensión 115/230 V, 50/60 Hz) y BH1023-6AAA-HV4-BA0 (tensión fija 100/200 V, 50/60 Hz).

Technical Data

Parameter Value Condición
Rated pressure (vacuum) -64 inch H2O p.2 ↗ BH1023-6AAA-HV5-BA0, 50 Hz
Rated pressure (vacuum) -56 inch H2O p.2 ↗ BH1023-6AAA-HV5-BA0, 60 Hz
Voltage 115 / 230 V p.2 ↗ BH1023-6AAA-HV5-BA0, 50 Hz
Voltage 115 / 230 V p.2 ↗ BH1023-6AAA-HV5-BA0, 60 Hz
Current 19,0 / 9,5 A p.2 ↗ BH1023-6AAA-HV5-BA0, 50 Hz
Current 20,0 / 10,0 A p.2 ↗ BH1023-6AAA-HV5-BA0, 60 Hz
Power 2,0 hp p.2 ↗ BH1023-6AAA-HV5-BA0, 50 Hz
Power 2,3 hp p.2 ↗ BH1023-6AAA-HV5-BA0, 60 Hz
Sound pressure level 69 dB(A) p.2 ↗ BH1023-6AAA-HV5-BA0, 50 Hz
Sound pressure level 70 dB(A) p.2 ↗ BH1023-6AAA-HV5-BA0, 60 Hz
Weight 68 lbs p.2 ↗ BH1023-6AAA-HV5-BA0, 50 Hz
Weight 70 lbs p.2 ↗ BH1023-6AAA-HV5-BA0, 60 Hz
Protection category IP 55 p.1 ↗ standard motors
Insulation class F p.1 ↗ standard motors

Operating Limits

  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Single-phase voltage tolerance: ± 5 % p.2 ↗

Type Code Decoder

Position Token Meaning
1-9 p.2 ↗ BH1023-6 Blower type / size designation (2BH1530)
10-12 p.2 ↗ AAA Basic design / configuration code
14-16 p.2 ↗ HV5 Motor voltage variant: voltage range 115/230 V, 50/60 Hz (HV4 = fixed voltage 100/200 V)
18-20 p.2 ↗ BA0 Further design / options code