Bombas de vacío de anillo líquido sin aceite de la serie NEV2 (evolución de la serie 2BV2): modelos NEV2 060, NEV2 061, NEV2 070, NEV2 071; datos de rendimiento a 50 Hz y 60 Hz; variantes de material fundición/fundición/bronce y acero inoxidable (1.4581); números de pedido por modelo y variante de tensión.

Technical Data

Parameter Value Condición
Max. pumping speed 27 m3/h p.6 ↗ NEV2 060, 50/60 Hz
Motor rated output 0.81 kW p.6 ↗ NEV2 060, 50/60 Hz
Rated voltage 220 V p.6 ↗ NEV2 060, 50/60 Hz
Rated current 5.0 A p.6 ↗ NEV2 060, 50/60 Hz
Sound pressure level 62 dB(A) p.6 ↗ NEV2 060, 50/60 Hz
Weight approx. 24 kg p.6 ↗ NEV2 060, 50/60 Hz
Max. pumping speed 48 m3/h p.6 ↗ NEV2 061, 50/60 Hz
Motor rated output 1.45 kW p.6 ↗ NEV2 061, 50/60 Hz
Rated voltage 220 V p.6 ↗ NEV2 061, 50/60 Hz
Rated current 6.6 A p.6 ↗ NEV2 061, 50/60 Hz
Sound pressure level 65 dB(A) p.6 ↗ NEV2 061, 50/60 Hz
Weight approx. 25 kg p.6 ↗ NEV2 061, 50/60 Hz
Max. pumping speed 80 m3/h p.6 ↗ NEV2 070, 50/60 Hz
Motor rated output 2.35 kW p.6 ↗ NEV2 070, 50/60 Hz
Rated voltage 220 V p.6 ↗ NEV2 070, 50/60 Hz
Rated current 12.1 A p.6 ↗ NEV2 070, 50/60 Hz
Sound pressure level 66 dB(A) p.6 ↗ NEV2 070, 50/60 Hz
Weight approx. 43.2 kg p.6 ↗ NEV2 070, 50/60 Hz
Max. pumping speed 110 m3/h p.6 ↗ NEV2 071, 50/60 Hz
Motor rated output 3.85 kW p.6 ↗ NEV2 071, 50/60 Hz
Rated voltage 380 V p.6 ↗ NEV2 071, 50/60 Hz
Rated current 9.4 A p.6 ↗ NEV2 071, 50/60 Hz
Sound pressure level 72 dB(A) p.6 ↗ NEV2 071, 50/60 Hz
Weight approx. 53 kg p.6 ↗ NEV2 071, 50/60 Hz
Protection rating IP55 p.3 ↗ NEV2 series

Operating Limits

  • Max. inlet pressure (vacuum): 27 mbarA (97% vacuum) p.3 ↗
  • Min. inlet pressure with atmospheric ejector: 10 mbarA p.3 ↗
  • Cavitation protection required below inlet pressure: 80 mbarA p.3 ↗
  • Protection rating: IP55 p.3 ↗

Type Code Decoder

Position Token Meaning
1-4 p.6 ↗ NEV2 Series: oil-free liquid ring vacuum pump
5-7 p.6 ↗ 060 / 061 / 070 / 071 Size / model
11-13 p.6 ↗ 002 / 022 / 037 / 074 / 076 / 077 Voltage / frequency variant code

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
NEV2 060 p.6 ↗ ENEV20600NC002P cast iron/cast iron/bronze, 50/60 Hz
NEV2 061 p.6 ↗ ENEV20610NC022P cast iron/cast iron/bronze, 50/60 Hz
NEV2 070 p.6 ↗ ENEV20700NC002P cast iron/cast iron/bronze, 50/60 Hz
NEV2 071 p.6 ↗ ENEV20710NC037P cast iron/cast iron/bronze, 50/60 Hz
NEV2 060 p.6 ↗ ENEV20600NF074P cast iron/cast iron/bronze, 60 Hz
NEV2 061 p.6 ↗ ENEV20610NF074P cast iron/cast iron/bronze, 60 Hz
NEV2 070 p.6 ↗ ENEV20700NF076P cast iron/cast iron/bronze, 60 Hz
NEV2 071 p.6 ↗ ENEV20710NF077P cast iron/cast iron/bronze, 60 Hz
NEV2 060 p.7 ↗ ENEV20600NE002P stainless steel, 50 Hz
NEV2 061 p.7 ↗ ENEV20610NE022P stainless steel, 50 Hz

Modelos relacionados