VLU Digital Brochure EN
Technical Reference Summary
Covered Models & Document Scope
Serie de bombas de vacío de garras VLU, sin aceite, tamaños VLU 62, VLU 122, VLU 301, VLU 401, VLU 501, VLU 651 y VLU 1000; funcionamiento a 50 Hz y 60 Hz; vacío final hasta 30 mbar (abs.)
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Operating principle | Claw p.2 ↗ | |
| Lubrication type | Oil free p.2 ↗ | |
| Ultimate pressure | 30 mbar (abs.) p.2 ↗ | series minimum |
| Ultimate pressure | 50 mbar p.5 ↗ | VLU 62 |
| Ultimate pressure | 35 mbar p.5 ↗ | VLU 122 |
| Ultimate pressure | 30 mbar p.5 ↗ | VLU 301 |
| Ultimate pressure | 60 mbar p.5 ↗ | VLU 401, 501 |
| Ultimate pressure | 100 mbar p.5 ↗ | VLU 651, 1000 |
| Pumping speed | 0–1000 m³/h p.6 ↗ | 50 Hz and 60 Hz range |
| Maintenance interval | 4000 hours per year p.3 ↗ | TCO/maintenance basis |
Operating Limits
- Minimum ultimate vacuum (absolute): 30 mbar (abs.) p.2 ↗
- Maximum ultimate vacuum (absolute): 100 mbar p.5 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-3 p.2 ↗ | VLU | Series: oil-free claw vacuum pump |
| 4-7 p.5 ↗ | 62 / 122 / 301 / 401 / 501 / 651 / 1000 | Size designation |