Agilent Femto Pulse Controller Software README

Contenido

  1. Overview p. 2
    Overview of the Femto Pulse controller software and its purpose
  2. Spec p. 3
    Supported operating system and prerequisites for installation
  3. Procedure p. 4
    Instructions for downloading the Femto Pulse Prosize software
  4. Procedure p. 5
    Steps to install FTDI drivers and confirm success
  5. Procedure pp. 6-7
    Steps to install the Starlight Xpress CCD driver
  6. Procedure p. 8
    Continuing the installation wizard whenever prompted
  7. Procedure pp. 9-10
    Removing the Femto Pulse software via Windows settings

Engineering Facts

13 facts · every claim linked to a page
Selection

The controller software does not support ARM-based processors, so only x86 PCs with i5 or higher should be selected.

Prevents selecting incompatible ARM-based PCs or laptops for instrument control.

Source
“Processor: i5 or higher / ARM Processor not supported”
Selection

Minimum RAM is 4 GB on Windows 10 but 8 GB on Windows 11, so the OS choice dictates the PC memory requirement.

Ensures the chosen PC meets the higher memory requirement when running Windows 11.

Source
“Physical: Minimum 4 GB for Windows 10”
Selection

The display must provide at least 1280x1024 or 1280x800 pixels to run the software properly.

Avoids selecting monitors or laptops with insufficient screen resolution.

Source
“Min resolution of 1280x1024 or 1280x800 pixels”
Selection

Only 64-bit Windows 10 or Windows 11 with English (US) language and region settings is supported.

Prevents deployment on unsupported OS bitness or localized Windows configurations.

Source
“Microsoft © Windows 10 64 bit with English (US) language settings”
Selection

Windows 10 must be version 1803 or later, and Windows 11 must be 24H2 (OS Build 26100.3775).

Ensures the PC is imaged with a tested and supported OS build before installation.

Source
“Microsoft © Windows 10 64 bit 1803 or later”
Selection

Microsoft .NET 4.6.2 or higher is required on the controller PC.

Prevents installation failure due to missing or outdated .NET runtime.

Source
“Microsoft .NET: 4.6.2 or higher”
Operation

Automatic reporting requires Adobe Acrobat DC Reader 19.012.0034 or later to view and generate reports.

Ensures report generation and viewing work on the selected PC.

Source
“requires Adobe Acrobat DC Reader version 19.012.0034 or later to be able to view and generate reports”
Installation

Administrative rights are mandatory to install all required software components.

Prevents failed installations caused by restricted user accounts.

Source
“You need to have an account with administrative rights to successfully install all required components.”
Installation

All running programs, including any Femto Pulse controller subprogram instances, must be closed before installation.

Avoids file locks and installation conflicts during setup.

Source
“Close all running programs, including all instances of any Femto Pulse controller software subprogram.”
Installation

The installation package includes FTDI and Starlight Xpress CCD device drivers that must be installed before the controller software.

Confirms that instrument communication and CCD drivers are prerequisites for controller operation.

Source
“Once the FTDI drivers have been successfully installed, you will see the following window indicating the device driver is installed and is ready to use.”
Installation

The PC must be restarted after installation to ensure successful software installation.

Prevents driver or service initialization issues on first instrument use.

Source
“Re-start the PC to ensure successful software installation.”
Maintenance

If upgrading fails, existing Femto Pulse controller installations should be removed before retrying.

Provides a defined recovery path for failed software upgrades.

Source
“If you encounter problems whilst upgrading the Femto Pulse controller software, please remove the existing Femto Pulse controller software installations.”
Operation

Timeshift correction is applied at the end of the separation rather than to the real-time electropherogram in revision 2.1.0.

Affects how and when corrected separation data becomes available to the operator.

Source
“Timeshift correction no longer applied to real time electropherogram but applied at the end of the separation”