CC-112A Immersion Circulator Technical Data

Contenido

  1. Overview p. 1
    Product name and cover identification of the CC-112A unit
  2. Spec p. 2
    Technical data per DIN 12876 with tabulated parameters
  3. p. 2 table, 2 rows

Technical data according to DIN 12876

ParameterValue
max. ambient temperature40 °C
from Serial-No.:S419458

Engineering Facts

14 facts · every claim linked to a page
Selection

The operating temperature range depends on the cooling method, so the achievable minimum temperature must be checked against the chosen configuration.

Determines whether the bath can reach the required low temperature with water cooling or needs a refrigerator.

Source
“Operating temperature range 25...100 °C with water cooling 20...100 °C with refrigerator 15...100 °C”
Installation

The unit requires a 200-240 V single- or two-phase supply with a minimum 10 A fuse and maximum 16 A fuse.

Electrical supply and branch protection must be sized accordingly before installation.

Source
“Power supply requirement 200-240V 1~/2~ 50/60Hz max. current 10 A min. Fuse 10A max. Fuse 16A”
Installation

External branch circuit protection according to UL 489 is required.

The installer must provide a suitable UL 489 branch circuit protective device.

Source
“External branch circuit protection according to UL 489 required.”
Installation

Voltage and frequency tolerances are only permissible if they do not run in opposite directions.

Supply quality must be verified; some combined voltage/frequency deviations are not allowed.

Source
“Voltage + / - 10%, as long as the frequency tolerance does not run in the opposite direction.”
Installation

Single- and two-phase devices are delivered with a power cable and country-specific plug that must be specified at ordering.

The correct plug type must be ordered to avoid installation delays.

Source
“Single / two-phase devices (100V to 240V) --> with power cable and country-specific plug (please specify when ordering)”
Operation

The bath has a 12 l volume with a minimum filling capacity of 8 l.

Defines the required heat transfer fluid quantity and safe minimum fill level.

Source
“Bath volume 12 l min. filling capacity 8 l”
Operation

The pressure pump delivers up to 27 l/min at 0.7 bar, and the suction pump up to 22 l/min at 0.4 bar.

Pump performance must match the external circuit flow and pressure drop requirements.

Source
“max. delivery 27 l/min max. delivery pressure 0,7 bar Suction pump yes max. delivery (suction) 22 l/min max. delivery pressure (suction) 0,4 bar”
Operation

The ambient temperature must remain between 5 °C and 40 °C.

The installation location must stay within the allowed ambient range for reliable operation.

Source
“min. ambient temperature 5 °C”
Safety

The unit has safety classification III / FL according to DIN 12876 and adjustable overtemperature protection.

Safety class and overtemperature protection are relevant for flammable or sensitive bath applications.

Source
“Safety classification III / FL”
Safety

The degree of protection is IP20, so the unit is not protected against water ingress.

The installation site must be dry and protected from splashing water.

Source
“Degree of Protection IP20”
Operation

The bath bridge has a bore hole for a cooling probe such as an immersion cooler TC45-TC100E.

External cooling can be added through the bath bridge bore hole if lower temperatures are needed.

Source
“Bath bridge with bore hole for cooling probe (e.g. for immersion cooler TC45-TC100E).”
Operation

Polyglycol must not be used as heat transfer fluid when a Huber pump adapter is used.

Prevents selection of an incompatible heat transfer fluid with the pump adapter.

Source
“When using Huber pump adapter: Polyglycol is not permissible to be used as a heat transfer fluid”
Cumplimiento

The equipment is classified as Class A, Group 1 for electromagnetic disturbance according to EN55011.

Class A equipment may require additional EMC precautions in residential or sensitive environments.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Installation

Overall space requirements must be respected according to the operating conditions.

Clearances around the unit must be checked before final placement.

Source
“Please respect space requirements. See operating conditions at www.huber-online.com”