CC-225B Immersion Circulator — Technical Data Sheet

Contenido

  1. Overview p. 1
    Product identification and general description of the CC-225B unit
  2. Spec pp. 1-2
    Technical data table per DIN 12876 including temperature and performance ratings
  3. p. 1 table, 34 rows

Technical data according to DIN 12876

CharacteristicValue
Operating temperature range25...200 °C
with water cooling20...200 °C
with refrigerator-30...200 °C
Temperature stability at 70°C0,02 K
temperature set point / display5,7" colour Touchscreen
Absolute accuracysetup for calibration
Internal temperature sensorPt100
Sensor external connectionPt100
Interface digitalEthernet, USB (Host u. Device), RS232
Safety classificationIII / FL
Heating power at 240V2,1 kW
Heating power at 230V2 kW
Heating power at 220V1,8 kW
Heating power at 208V1,6 kW
Heating power at 200V1,5 kW
Pressure pump max. delivery27 l/min
max. delivery pressure0,7 bar
Suction pumpyes
max. delivery (suction)22 l/min
max. delivery pressure (suction)0,4 bar
Pump connenction (optional)M16x1 male
Bath volume23,5 l
min. filling capacity17 l
Width bath opening WxD/ bath depth290x329/ 200 mm
Overall dimensions WxDxH **350x555x425 mm
Net weight16 kg
Power supply requirement200-240V 1~/2~ 50/60Hz
max. current10 A
min. Fuse10A
max. Fuse16A
Pressure equipment categoryArt. 4.3 PED
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C

** Overall dimensions WxDxH

Engineering Facts

14 facts · every claim linked to a page
Selection

The achievable operating temperature range depends on the cooling method chosen: 25–200 °C without cooling, 20–200 °C with water cooling, and -30–200 °C with a refrigerator.

Determines whether an external cooler or refrigerator is required for the intended process temperature.

Source
“Operating temperature range 25...200 °C with water cooling 20...200 °C with refrigerator -30...200 °C”
Installation

The unit accepts 200–240 V single- or two-phase supply at 50/60 Hz and draws up to 10 A, so branch protection must be sized between 10 A and 16 A.

Needed to plan the electrical supply, cable, and fuse rating at the installation site.

Source
“Power supply requirement 200-240V 1~/2~ 50/60Hz max. current 10 A min. Fuse 10A max. Fuse 16A”
Installation

Voltage and frequency tolerances of ±10% are only acceptable if they do not act in opposite directions, so supply quality must be verified before commissioning.

Prevents installation on a supply whose combined voltage/frequency deviation is outside the permitted envelope.

Source
“Voltage + / - 10%, as long as the frequency tolerance does not run in the opposite direction.”
Safety

External branch circuit protection according to UL 489 is mandatory, so the site must provide a suitable UL-listed breaker.

Affects the electrical panel design and compliance of the installation.

Source
“External branch circuit protection according to UL 489 required.”
Installation

Single- and two-phase devices are delivered with a power cable and country-specific plug that must be specified at ordering.

The correct plug type must be stated on the order to avoid rework at installation.

Source
“Single / two-phase devices (100V to 240V) --> with power cable and country-specific plug (please specify when ordering)”
Installation

Three-phase devices below 63 A arrive with cable but without plug, and above 63 A without cable or plug, so the site must plan termination hardware.

Determines what electrical termination work and hardware the installer must provide.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Operation

The bath requires a minimum filling of 17 l within its 23.5 l volume, so the heat transfer fluid charge must be planned accordingly.

Sets the minimum fluid quantity needed for safe pump operation and the fluid volume to procure.

Source
“Bath volume 23,5 l min. filling capacity 17 l”
Operation

The pressure pump delivers up to 27 l/min at 0.7 bar and the suction pump up to 22 l/min at 0.4 bar, which bounds the external circuit resistance that can be served.

Used to check whether the external loop and connected equipment can be supplied by the pump.

Source
“max. delivery 27 l/min max. delivery pressure 0,7 bar”
Operation

When a Huber pump adapter is used, polyglycol must not be employed as the heat transfer fluid.

Restricts fluid selection when the pump adapter accessory is fitted.

Source
“When using Huber pump adapter: Polyglycol is not permissible to be used as a heat transfer fluid”
Installation

The bath bridge has a hole for a cooling probe intended for immersion coolers TC45–TC100E, so an external cooler can be integrated.

Allows planning of an immersion cooler for operation below ambient temperature.

Source
“Bath bridge with hole for cooling probe (e.g. for immersion cooler TC45-TC100E).”
Safety

The unit provides adjustable overtemperature protection according to DIN 12876, which must be set for the application.

The safety cut-out setting must be configured to protect the fluid and process.

Source
“With adjustable overtemperature protection according to DIN 12876.”
Installation

The enclosure is rated IP20, so the unit must be kept in a dry, protected location and not exposed to water.

Constrains the installation environment and cleaning method.

Source
“Degree of Protection IP20”
Installation

Ambient temperature at the installation site must stay between 5 °C and 40 °C.

Defines the allowable room conditions for correct and safe operation.

Source
“min. ambient temperature 5 °C max. ambient temperature 40 °C”
Cumplimiento

The equipment is classified as Class A, Group 1 for electromagnetic disturbance to EN55011, so it may cause interference in residential environments.

Affects EMC planning and suitability for residential or sensitive laboratory locations.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”