Minichiller 600w-H Datasheet

Contenido

  1. Overview p. 1
    Product introduction and key features of the Minichiller 600w-H
  2. Spec p. 2
    Technical data according to DIN 12876 for the chiller
  3. p. 2 table, 18 rows
  4. p. 1 table, 23 rows

Technical data according to DIN 12876

ParameterValue
max. delivery (suction)18 l/min
max. delivery pressure (suction)0,4 bar
Pump connectionM16x1 male
Cooling water connectionG1/2 male
min. cooling water differential pressure3 bar
max. cooling water pressure6 bar
min. filling capacity2,8 l
Volume of expansion2,2 l
Overall dimensions WxDxH **280x490x424 mm
Net weight36 kg
Power supply requirement208-240V 1~/2~ 50/60Hz
max. current12 A
Fuse16 A
Pressure equipment categoryArt. 4.3 PED
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:S577946

** Please respect space requirements. See operating conditions at www.huber-online.com

Technical data according to DIN 12876 — Minichiller 600w-H (Order-No.: 3066.0020.01)

ParameterValue
Operating temperature range-20...100 °C
temperature set point / display5,7" colour Touchscreen
Internal temperature sensorPt100
Sensor external connectionPt100
Temperature stability at -10°C0,2 K
Interface digitalEthernet, USB (Host u. Device), RS232
Safety classificationIII / FL
Heating power at 240V2,1 kW
Heating power at 230V2 kW
Heating power at 220V1,8 kW
Heating power at 208V1,6 kW
Cooling power at ambient temperature +20°C at 15°C0,6 kW
Cooling power at ambient temperature +20°C at 0°C0,5 kW
Cooling power at ambient temperature +20°C at -10°C0,35 kW
Cooling power at ambient temperature +20°C at -20°C0,15 kW
Refrigeration machinewater-cooled, natural refrigerant
Refrigerant (ASHRAE, GHS)R-290 (A3, H220)
Global Warming Potential (GWP)0,02
Refrigerant quantity0,06 kg
CO2 equivalent0,0 t
Circulation pumpPressure- and suction pump
max. delivery24 l/min
max. delivery pressure0,7 bar

Значения приведены дословно по тексту страницы; блоки «switch for whisper mode» и «Pump data for whisper mode» в таблицу технических данных не включены.

Engineering Facts

13 facts · every claim linked to a page
Installation

The chiller requires cooling water with a minimum differential pressure of 3 bar and a maximum pressure of 6 bar, so the site water supply must be sized accordingly.

Ensures the cooling water circuit can deliver adequate flow and pressure without exceeding component ratings.

Source
“min. cooling water differential pressure 3 bar”
Installation

Cooling water inlet temperature must be between 5°C and 20°C; below the condensation point the cooling water pipes inside the unit must be insulated.

Prevents condensation and ensures rated cooling performance; dictates water supply design and insulation.

Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Performance

Cooling power is rated at 0.6 kW at 15°C, 0.5 kW at 0°C, 0.35 kW at -10°C and 0.15 kW at -20°C, so capacity drops significantly at lower temperatures.

Allows correct sizing of the chiller for the actual process temperature and heat load.

Source
“Cooling power at ambient temperature +20°C”
Safety

The refrigerant is R-290 (propane, A3, H220) with a charge of 0.06 kg, which is flammable and requires appropriate safety measures.

Flammable refrigerant affects installation location, ventilation, and safety classification (III / FL).

Source
“R-290 (A3, H220)”
Operation

The plastic pump is not resistant to acetone or polyglycols, so these fluids must be avoided or a more resistant pump ordered.

Prevents pump damage and process contamination when selecting the heat transfer fluid.

Source
“The plastic pump is not resistant against acetone and polyglycols (depending on the manufacturer).”
Installation

The unit requires a 208-240 V single/two-phase 50/60 Hz supply with a maximum current of 12 A and a 16 A fuse.

Determines electrical supply, cabling and protection device sizing at the installation site.

Source
“Power supply requirement 208-240V 1~/2~ 50/60Hz”
Installation

Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and combinations such as -5% voltage with +2% frequency are not allowed.

Ensures the site power quality is within the allowed envelope to avoid damage or malfunction.

Source
“-5% voltage and +2% frequency -> not allowed!”
Installation

The degree of protection is IP20, so the unit must be installed in a dry, protected environment.

Restricts installation location regarding moisture and dust ingress.

Source
“Degree of Protection IP20”
Operation

Ambient temperature must be between 5°C and 40°C for proper operation.

Defines the allowable room conditions and affects cooling performance and reliability.

Source
“min. ambient temperature 5 °C”
Installation

The minimum filling capacity is 2.8 l and the expansion volume is 2.2 l, which must be considered when sizing the external circuit.

Ensures sufficient heat transfer fluid volume and expansion space in the system.

Source
“min. filling capacity 2,8 l”
Installation

Cooling water circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only suitable cooling water may be used.

Guides water quality requirements to avoid corrosion and fouling.

Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Operation

Whisper mode reduces sound pressure level to 51 dB(A) ±4 dB(A) but also reduces pump delivery to 14 l/min and 0.2 bar.

Trade-off between noise and pump performance must be considered for the application.

Source
“Reduced sound pressure level: 51 dB(A): +/- 4 dB(A)”
Cumplimiento

The equipment is classified as Class A, Group 1 for electromagnetic disturbance according to EN55011.

Class A equipment may require additional EMC measures in residential or light industrial environments.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”