Minichiller 800w OLÉ Technical Data

Contenido

  1. Overview p. 1
    Product cover and model identification for Minichiller 800w OLÉ
  2. Spec p. 2
    Technical data per DIN 12876 including performance and dimensions
  3. p. 2 table, 12 rows

Technical data according to DIN 12876

ParameterValue
expansion tank2,2 l
Overall dimensions WxDxH **280x490x424 mm
Net weight38 kg
Power supply requirement208-240V 1~/2~ 50/60Hz
max. current4 A
min. Fuse10A
max. Fuse16A
Pressure equipment categoryArt. 4.3 PED
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:S564373

** Please respect space requirements. See operating conditions at www.huber-online.com

Engineering Facts

12 facts · every claim linked to a page
Installation

The chiller requires cooling water with a differential pressure between 3 and 6 bar, so the site water supply must be verified before installation.

Insufficient or excessive cooling water pressure will prevent proper operation or damage the unit.

Source
“min. cooling water differential pressure 3 bar max. cooling water pressure 6 bar”
Installation

Cooling water inlet temperature must be kept between 5°C and 20°C, and pipes must be insulated if condensation occurs.

Out-of-range cooling water temperature reduces cooling capacity and can cause condensation and corrosion.

Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Selection

The unit uses flammable R-290 refrigerant (A3, H220), which affects safety classification and site requirements.

Flammable refrigerant requires appropriate safety measures and may restrict installation location.

Source
“Refrigerant (ASHRAE, GHS) R-290 (A3, H220)”
Selection

The plastic pump is not resistant to acetone or polyglycols, so these media must be avoided or a more resistant pump specified.

Using incompatible media will damage the pump and void reliable operation.

Source
“The plastic pump is not resistant against acetone and polyglycols (depending on the manufacturer).”
Operation

The permissible return line temperature is 80°C, which defines the upper limit for the application.

Exceeding this temperature can damage the unit and must be considered when selecting the process.

Source
“Permissible temperature in return line 80 °C”
Installation

The electrical supply must be 208-240V single or two-phase at 50/60Hz with a fuse between 10A and 16A.

Correct supply and fuse rating are essential for safe and reliable electrical installation.

Source
“Power supply requirement 208-240V 1~/2~ 50/60Hz max. current 4 A min. Fuse 10A max. Fuse 16A”
Installation

Voltage and frequency tolerances are ±5% and ±2% respectively, but the combination of -5% voltage and +2% frequency is not allowed.

Non-compliant supply conditions can cause malfunction or damage and must be checked at the site.

Source
“-5% voltage and +2% frequency -> not allowed!”
Operation

The whisper mode reduces sound pressure to 51 dB(A) but also reduces pump delivery to 14 l/min and 0.2 bar.

If low noise is required, the reduced pump performance must be acceptable for the process.

Source
“Pump data for whisper mode: Delivery rate: 14 l/min Delivery pressure: 0.2 bar”
Installation

The unit has IP20 protection, so it must be installed in a dry environment protected from water ingress.

IP20 is not water-resistant and limits installation to indoor dry locations.

Source
“Degree of Protection IP20”
Operation

Ambient temperature must be between 5°C and 40°C for proper operation.

Operating outside this range can affect cooling performance and reliability.

Source
“min. ambient temperature 5 °C max. ambient temperature 40 °C”
Maintenance

The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only suitable cooling water may be used.

Incompatible water quality can cause corrosion or fouling, affecting maintenance and lifetime.

Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Selection

Cooling power drops from 0.8 kW at 15°C to 0.3 kW at -20°C, which must be considered for low-temperature applications.

Available cooling capacity decreases significantly at lower temperatures, affecting process design.

Source
“Cooling power at 15°C 0,8 kW at 0°C 0,6 kW at -10°C 0,45 kW at -20°C 0,3 kW”