Introduces the Unichiller 030Tw chiller unit and its main features
Specpp. 1-2
Lists performance, temperature, and physical specifications per DIN 12876
p. 2table, 11 rows
p. 1table, 34 rows
Technical data according to DIN 12876
Parameter
Value
Overall dimensions WxDxH **
400x440x1230 mm
Net weight
137 kg
sound pressure level +/- 4 dB(A)
61 dB(A)
Power supply (3 Phase)
400V 3~ 50Hz
max. current (3 Phase)
4,5 A
Fuse (3 phase)
3x10A
Pressure equipment category
Art. 4.3 PED
Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.:
S517916
** Please respect space requirements. See operating conditions at www.huber-online.com
Technical data according to DIN 12876 — Unichiller 030Tw (Order-No.: 3025.0056.01)
Parameter
Value
Operating temperature range
-20...40 °C
temperature set point / display
5,7" colour Touchscreen
Internal temperature sensor
Pt100
Sensor external connection
Pt100
Temperature stability at -10°C
0,5 K
Interface digital
Ethernet, USB (Host u. Device), RS232
Safety classification
I / NFL
Cooling power at 15°C
3 kW
Cooling power at 0°C
2,75 kW
Cooling power at -10°C
2 kW
Cooling power at -20°C
1 kW
Refrigeration machine
water-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)
R-449A (A1, H280)
Global Warming Potential (GWP)
1397
Refrigerant quantity
0,7 kg
CO2 equivalent
1,0 t
Circulation pump
B
max. delivery
26 l/min
max. delivery pressure
3 bar
Delivery at 0,2 bar
22 l/min
Delivery at 0,5 bar
20 l/min
Delivery at 1,0 bar
16 l/min
Delivery at 1,5 bar
12 l/min
Delivery at 2,0 bar
8 l/min
Pump connection
G3/4 male
Cooling water connection
G1/2 male
Consumption at water 15°C, flow 15°C
99 l/h
Consumption at water 15°C, flow 0°C
99 l/h
Consumption at water 15°C, flow -10°C
65 l/h
Consumption at water 15°C, flow -20°C
25 l/h
min. cooling water differential pressure
1 bar
max. cooling water pressure
6 bar
min. filling capacity
2,5 l
Volume of expansion
4 l
Engineering Facts
12 facts · every claim linked to a page
Installation
The chiller is water-cooled and requires a cooling water differential pressure of at least 1 bar and no more than 6 bar at the connection.
Ensures the facility cooling water supply can meet the minimum pressure for proper operation without exceeding the maximum.
Source
“min. cooling water differential pressure 1 bar”
Installation
The unit is designed for cooling water intake between 5°C and 20°C, and pipes must be insulated if the water temperature can fall below the condensation point.
Defines the allowable cooling water supply temperature range and condensation protection requirement for installation.
Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Performance
Cooling power drops as cooling water temperature rises, and the required cooling water flow rate may increase.
Engineers must account for reduced capacity and higher water demand when the facility cooling water is warmer than the rated 15°C.
Source
“As the cooling water temperature increases, drop in the cooling power should be expected, and also an increased cooling water flow rate possible.”
Installation
The cooling water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible cooling water may be used.
Material compatibility determines water quality requirements and prevents corrosion or damage in the cooling circuit.
Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Installation
Three-phase devices with current consumption below 63 A are supplied with a cable but without a plug.
The installer must provide and fit a suitable plug or hard-wire the supplied cable on site.
Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Cumplimiento
Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and certain combinations such as -5% voltage with +2% frequency are not allowed.
Power supply quality must be verified against these combined tolerances to avoid invalid operating conditions.
Source
“-5% voltage and +2% frequency -> not allowed!”
Safety
The refrigerant R-449A is classified A1 with GHS hazard H280, and the charge is 0.7 kg corresponding to 1.0 t CO2 equivalent.
Affects refrigerant handling, leak reporting obligations and safety classification for the installation site.
Source
“R-449A (A1, H280)”
Installation
The unit has protection degree IP20 and must be operated within an ambient temperature of 5°C to 40°C.
IP20 limits installation to dry indoor locations and the ambient range constrains the room environment.
Source
“Degree of Protection IP20”
Selection
The chiller is intended for externally closed applications and has an atmospheric open expansion tank.
Confirms the hydraulic circuit type the unit is designed for, preventing misapplication with open baths or unsuitable loops.
Source
“For externally closed applications.”
Operation
The pump delivers 26 l/min maximum and 8 l/min at 2.0 bar, with G3/4 male pump connections.
Pump curve data is needed to match the external circuit pressure drop and required flow.
Source
“max. delivery 26 l/min”
Installation
The unit requires a 400 V 3~ 50 Hz supply with maximum current 4.5 A and 3x10 A fusing.
Electrical supply and protection must be provisioned accordingly before installation.
Source
“Power supply (3 Phase) 400V 3~ 50Hz”
Maintenance
The minimum filling capacity is 2.5 l and the expansion volume is 4 l.
Determines the minimum heat transfer fluid volume needed and expansion allowance for the external loop.