Product introduction and main features of the chiller
Specpp. 1-2
Technical data and performance specifications per DIN 12876
p. 2table, 4 rows
p. 1table, 33 rows
Technical data according to DIN 12876
Parameter
Value
Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.:
1.0/24
Unichiller P230 — Technical data according to DIN 12876
Parameter
Value
Order-No.
3039.0023.01
Operating temperature range
-20...40 °C
temperature set point / display
5,7" colour Touchscreen
Internal temperature sensor
Pt100
Sensor external connection
Pt100
Temperature stability at -10°C
0,5 K
Interface digital
Ethernet, USB (Host u. Device), RS232
Safety classification
I / NFL
Cooling power at ambient temperature +20°C
at 20°C
23 kW
at 0°C
13,5 kW
at -10°C
9 kW
at -20°C
5,5 kW
Refrigeration machine
air-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)
R-449A (A1, H280)
Global Warming Potential (GWP)
1397
Refrigerant quantity
1,49 kg
CO2 equivalent
2,1 t
Circulation pump:
E2
max. delivery
140 l/min
max. delivery pressure
5,3 bar
Delivery at 2,8 bar
126 l/min
Delivery at 3,0 bar
124 l/min
Delivery at 3,5 bar
115 l/min
Delivery at 4,0 bar
92 l/min
Delivery at 4,5 bar
83 l/min
Delivery at 5,0 bar
43 l/min
Pump connection
G1 1/4 male
min. filling capacity
18 l
Volume of expansion
48 l
Overall dimensions WxDxH **
938x1288x2003 mm
Power supply (3 Phase)
460V 3~ 60Hz
Pressure equipment category
I
** Overall dimensions WxDxH
Engineering Facts
14 facts · every claim linked to a page
Selection
The chiller is rated for an operating temperature range of -20 to 40 °C, so process requirements outside this window cannot be met.
Defines the application envelope and excludes processes needing lower or higher temperatures.
Source
“Operating temperature range
-20...40 °C”
Performance
Cooling capacity drops from 23 kW at 20 °C ambient to 5.5 kW at -20 °C, so sizing must use the capacity at the actual operating point.
Prevents undersizing when the process runs at low temperature or elevated ambient.
Source
“at 20°C
23 kW
at 0°C
13,5 kW
at -10°C
9 kW
at -20°C
5,5 kW”
Installation
The unit requires a 460 V three-phase 60 Hz supply, so site power must match this configuration.
Determines electrical infrastructure and whether a transformer or different model is needed.
Source
“Power supply (3 Phase)
460V 3~ 60Hz”
Installation
Three-phase devices below 63 A are delivered with cable but without plug, so the installer must provide a suitable connection.
Affects electrical installation planning and required site hardware.
Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Cumplimiento
External branch circuit protection according to UL 489 is required, so the panel must include a UL 489 listed breaker.
Mandatory for compliant installation and acceptance by electrical inspection.
Source
“External branch circuit protection according to UL 489 required.”
Installation
Voltage and frequency tolerances are ±5% and ±2% but cannot be combined in the unfavorable direction, so supply quality must be verified.
Avoids invalid supply conditions that could damage the compressor or void warranty.
Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Installation
The unit is IP20 and must be installed in an environment between 5 and 40 °C ambient, so it needs a protected indoor location.
Prevents installation in dusty, wet, or hot areas that would compromise operation.
Source
“Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C”
Selection
The refrigerant is R-449A with GWP 1397 and a CO2 equivalent of 2.1 t, which matters for environmental reporting and leak regulations.
Affects F-gas compliance, leak checks, and sustainability assessment.
Source
“Refrigerant (ASHRAE, GHS)
R-449A (A1, H280)
Global Warming Potential (GWP)
1397
Refrigerant quantity
1,49 kg
CO2 equivalent
2,1 t”
Installation
The pump connection is G1 1/4 male, so hoses and fittings must match this thread.
Ensures correct plumbing hardware is ordered before commissioning.
Source
“Pump connection
G1 1/4 male”
Operation
The expansion tank volume is 48 l and minimum filling capacity is 18 l, so the external loop volume and fluid charge must be planned accordingly.
Prevents overflow or insufficient fluid volume in the external circuit.
Source
“min. filling capacity
18 l
Volume of expansion
48 l”
Installation
Overall dimensions are 938x1288x2003 mm, so access and floor space must accommodate this footprint and height.
Needed for room planning, transport route, and service clearance.
Source
“Overall dimensions WxDxH **
938x1288x2003 mm”
Performance
The pump delivers 140 l/min maximum and 5.3 bar maximum pressure, with flow falling to 43 l/min at 5.0 bar, so system pressure drop must be checked against the pump curve.
Ensures the external circuit does not exceed available pump head and flow.