Installation
The unit requires a 460 V 3-phase 60 Hz supply with a 3x63 A fuse, so the electrical infrastructure must be sized accordingly.
Determines site power availability, cable sizing and breaker selection before purchase.
Source
“Power supply requirement 460V 3~ 60Hz”
Installation
The cooling water supply must be between 5 °C and 20 °C with at least 1 bar differential pressure and no more than 6 bar.
Cooling water conditions directly affect achievable cooling power and must be verified on site.
Source
“This temperature control unit is designed to operate with cooling water intake temperature between 5°C and 20°C.”
Installation
Cooling water pipes must be insulated if the water temperature can fall below the condensation point.
Prevents condensation damage and corrosion in the cooling water circuit.
Source
“When cooling water temperatures fall below the condensation point, it is essential to insulate the cooling water pipes in the unit.”
Installation
The cooling water circuit uses copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM, so only compatible water quality may be used.
Guides water treatment and material compatibility to avoid corrosion and fouling.
Source
“Materiels used in the cooling water circuit include; copper, Stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.”
Installation
Voltage tolerance is ±5% only with a simultaneous frequency tolerance of ±2%, and certain combinations are not allowed.
Defines acceptable supply quality and warns against out-of-tolerance combinations that could damage the unit.
Source
“Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2%”
Safety
Leakage current exceeds 3.5 mA, so external branch circuit protection per UL 489 is mandatory.
Requires proper protective device selection and grounding to meet electrical safety.
Source
“Attention: leakage current > 3,5mA”
Installation
Three-phase devices drawing less than 63 A are supplied with cable but without a plug.
The customer must plan for on-site plug/connection hardware and qualified electrician work.
Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Selection
Cooling power drops significantly at low temperatures, from 16 kW at -20 °C to 1.8 kW at -90 °C.
Critical for sizing the unit for low-temperature process loads.
Source
“at -90°C 1,8 kW”
Selection
The refrigerant R-452A has a GWP of 2141 and 5 kg charge, giving 10.7 t CO2 equivalent; the second stage R-23 adds 32.6 t.
Affects environmental compliance, refrigerant handling regulations and total CO2 footprint.
Source
“CO2 equivalent 10,7 t”
Operation
The pump delivers 168 l/min at 0.5 bar but only 66 l/min at 2.0 bar, so system pressure drop must be matched to the pump curve.
Ensures adequate circulation flow through the external circuit at the actual pressure drop.
Source
“Delivery at 2,0 bar 66 l/min”
Operation
Maximum permissible kinematic viscosity of the heat transfer fluid is 50 mm²/s.
Limits fluid selection at low temperatures to avoid pump overload and poor heat transfer.
Source
“max. permissible kin. viscosity 50 mm²/s”
Installation
Minimum filling capacity is 12 l and the expansion tank holds 29 l, which sets the minimum fluid charge and expansion allowance.
Needed to plan fluid volume, expansion volume and external loop volume.
Source
“min. filling capacity 12 l”
Operation
The unit is rated IP20 and must operate between 5 °C and 40 °C ambient.
Defines the allowable room environment and protection level for installation planning.
Source
“max. ambient temperature 40 °C”
Cumplimiento
The unit is classified as EMC Class A, Group 1, which is intended for industrial environments.
May restrict use in residential areas and requires consideration of nearby sensitive equipment.
Source
“Classification (disturbance) to EN55011: Class A, Group 1”