Induztr
Resumen técnico Visor de documentos Modelos relacionados

Competent Cells

Contenido

  1. Overview pp. 1-2
    Introduction to competent cells product line and selection guide
  2. Overview pp. 3-4
    Protein expression competent cells and their features
  3. Spec p. 5
    Description of Hte and Hee phenotypes for transformation efficiency
  4. Spec p. 6
    XL10-Gold ultracompetent cells features and benefits
  5. Spec p. 7
    Improved ElectroTen-Blue electrocompetent cells characteristics
  6. Procedure pp. 8-9
    Strategies for cloning difficult and methylated DNA
  7. Overview p. 10
    Protein expression competent cells and vectors overview
  8. Procedure p. 11
    Polymerase-based cloning and mutagenesis procedures
  9. Spec p. 12
    XL1-Blue strain characteristics and applications
  10. Overview p. 13
    Convenient cloning competent cells and workflows
  11. Procedure p. 14
    Generating unmethylated DNA using competent cells
  12. Overview p. 15
    Wide selection of competent cells for various applications
  13. p. 16
    Appendix with additional technical information
  14. Ordering pp. 17-18
    Product ordering information with catalog numbers and sizes
  15. Spec p. 19
    Genotypes of competent cell strains
  16. p. 20
    Contact and additional learning resources
  17. p. 17 table, 24 rows
  18. p. 18 table, 21 rows
  19. p. 3 table, 23 rows
  20. p. 10 table, 10 rows
  21. p. 19 table, 27 rows

Ordering Information

ProductSizeDescriptionAntibiotic ResistanceCatalog #
Cloning Large or Ligated DNA
XL10-Gold Ultracompetent Cells5 x 0.1 mL aliquotsHighest cloning efficiency. Use with large plasmids, ligated DNA and plasmid libraries. ≥ 5 x 109 transformants/µgTetracycline resistant Chloramphenicol resistant*#200314
XL10-Gold Ultracompetent Cells10 x 0.1 mL aliquots#200315
ElectroTen-Blue Electroporation-Competent Cells5 x 0.1 mL aliquotsHighest electroporation cloning efficiency. Use for cloning ligated DNA and generating libraries. StrataClean resin included. ≥ 3 x 1010 transformants/µgTetracycline resistant Kanamycin resistant#200159
Convenient Cloning
SoloPack Gold Supercompetent Cells15 single-tube transformationsFor high-efficiency cloning. Convenient single-reaction format ≥ 1 x 109 transformants/µgTetracycline resistant Chloramphenicol resistant*#230350
SoloPack Gold Competent Cells15 single-tube transformationsFor routine cloning. Convenient single-reaction format ≥ 1 x 108 transformants/µgTetracycline resistant Chloramphenicol resistant*#230325
Routine Cloning
XL1-Blue Electroporation-Competent Cells5 x 0.1 mL aliquotsFor electroporation. ≥ 1 x 1010 transformants/µgTetracycline resistant#200228
XL1-Blue MRF' Electroporation-Competent Cells5 x 0.1 mL aliquotsFor electroporation. Restriction minus for cloning methylated DNA ≥ 1 x 1010 transformants/µgTetracycline resistant#200158
XL2-Blue Ultracompetent Cells10 x 0.1 mL aliquotsHighest cloning efficiency. ≥ 5 x 109 transformants/µgTetracycline resistant Chloramphenicol resistant*#200150
XL2-Blue MRF' Ultracompetent Cells10 x 0.1 mL aliquotsRestriction minus for cloning methylated DNA. Highest cloning efficiency. ≥ 5 x 109 transformants/µgTetracycline resistant Chloramphenicol resistant*#200151
XL1-Blue Supercompetent Cells5 x 0.2 mL aliquotsFor high-efficincy cloning. ≥ 1 x 109 transformants/µgTetracycline resistant#200236
XL1-Blue MR Supercompetent Cells5 x 0.2 mL aliquotsUse for cloning without the F' episome. ≥ 1 x 108 transformants/µg#200229
XL1-Blue Competent Cells5 x 0.2 mL aliquotsFor routine cloning. ≥ 1 x 108 transformants/µgTetracycline resistant#200249
XL1-Blue Subcloning-Grade Competent Cells8 x 0.5 mL aliquotsFor cloning where DNA is not limited. ≥ 1 x 106 transformants/µgTetracycline resistant#200130
Cloning Unstable DNA
SURE 2 Supercompetent Cells5 x 0.1 mL aliquotsHigh-efficiency derivative. ≥ 1 x 109 transformants/µgTetracycline resistant Chloramphenicol resistant* Kanamycin resistant#200152
SURE Competent Cells5 x 0.2 mL aliquots≥ 5 x 108 transformants/µgTetracycline resistant Kanamycin resistant#200238
SURE Electroporation-Competent Cells5 x 0.1 mL aliquotsFor electroporation. ≥ 1 x 109 transformants/µgTetracycline resistant* Kanamycin resistant#200227
Protein Expression
BL21-CodonPlus (DE3)-RIPL Competent Cells10 x 0.1 mL aliquotsUse to eliminate codon bias. Use with pET or pCAL vectors. Encodes T7 RNA polymerase under the control of the lacUV5 promoter for easy induction of protein expression. ≥ 1 x 106 transformants/µgChloramphenicol resistant* Streptomycin/Spectinomycin resistant#230280
BL21-CodonPlus RIL Competent Cells10 x 0.1 mL aliquotsUse to eliminate codon bias. Use for non-T7 polymerase systems. Use with λCE6 for extremely tight control of expression. ≥ 1 x 107 transformants/µgTetracycline resistant Chloramphenicol resistant*#230240
BL21-CodonPlus (DE3)-RIL Competent Cells10 x 0.1 mL aliquotsUse to eliminate codon bias. Use with pET or pCAL vectors. Encodes T7 RNA polymerase under the control of the lacUV5 promoter for easy induction of protein expression. ≥ 1 x 107 transformants/µgTetracycline resistant Chloramphenicol resistant*#230245

*Chloramphenicol resistance is provided by a plasmid; see the instruction manual.

Ordering Information Continued

ProductQuantityDescriptionEfficiencyResistanceCatalog #
BL2-CodonPlus (DE3)-RP Competent Cells10 x 0.1 mL aliquotsUse to eliminate bias. Use with pET or pCAL vectors. Encodes T7 RNA polymerase under the control of the lacUV5 promoter for easy induction of protein expression.≥ 1 x 107 transformants/µgTetracycline resistant; Chloramphenicol resistant*#230255
BL21-Gold Cells10 x 0.1 mL aliquotsIncreased efficiency and EndA- for cloning many expression constructs. Use with non-T7 RNA polymerase-based systems or extremely toxic proteins.≥ 1 x 108 transformants/µgTetracycline resistant#230130
BL21-Gold(DE3) Cells10 x 0.1 mL aliquotsIncreased efficiency and EndA- for cloning many expression constructs. Use with nontoxic proteins.≥ 1 x 108 transformants/µgTetracycline resistant#230132
BL21-Gold(DE3)pLysS Cells10 x 0.1 mL aliquotsIncreased efficiency and EndA- for cloning many expression constructs. Use with both toxic and nontoxic proteins.≥ 1 x 108 transformants/µgTetracycline resistant; Chloramphenicol resistant*#230134
BL21 Cells5 x 0.2 mL aliquotsUse with non-T7 polymerase-based systems or with λCE6 for extremely toxic proteins.≥ 1 x 106 transformants/µg#200133
BL21(DE3) Cells5 x 0.2 mL aliquotsUse with nontoxic proteins.≥ 1 x 106 transformants/µg#200131
BL21(DE3)pLysS Cells5 x 0.2 mL aliquotsUse with both toxic and nontoxic proteins.≥ 1 x 106 transformants/µgChloramphenicol resistant*#200132
ABLE K Cells5 x 0.2 mL aliquotABLE K≥ 5 x 106 transformants/µgTetracycline resistant; Kanamycin resistant#200172
XL1-Red Cells5 x 0.2 mL aliquotsFor random mutagenesis. Provided with XL1-Blue Competent cells.Tetracycline resistant#200129
SCS110 Cells5 x 0.2 mL aliquotsEndA- for improved yield and quality of miniprep DNA.≥ 5 x 106 transformants/µgStreptomycin resistant#200247
JM110 Cells5 x 0.2 mL aliquots≥ 5 x 106 transformants/µgStreptomycin resistant#200239
ElectroTen--Blue Electroporation-Competent Cells5 x 0.1 mL aliquotsHighest electroporation cloning efficiency. Use for cloning ligated DNA and generating libraries≥ 3 x 1010 transformants/µgTetracycline resistant; Kanamycin resistant#200159
XL1-Blue Electroporation-Competent Cells5 x -0.1 mL aliquotsFor all-purpose cloning≥ 1 x 1010 transformants/µgTetracycline resistant#200228
XL1-Blue MRF' Electroporation-Competent Cells5 x 0.1 mL aliquotsRestriction minus for cloning methylated DNA.≥ 1 x 1010 transformants/µgTetracycline resistant#200158
SURE Electroporation-Competent Cells5 x 0.1 mL aliquotsFor cloning unstable DNA≥ 1 x 1010 transformants/µgTetracycline resistant; Kanamycin resistant#200227
TG1 Electroporation-Competent Cells5 x 0.1 mL aliquotsFor phage display.≥ 1 x 1010 transformants/µg#200123
SCS1 Supercompetent Cells5 x 0.1 mL aliquots≥ 1 x 109 transformants/µg#200231
JM101 Competent Cells5 x 0.2 mL aliquots≥ 1 x 108 transformants/µg#200234
JM109 Competent Cells5 x 0.2 mL aliquots≥ 1 x 108 transformants/µg#200235
AMP Tabs200 x 25 mg tabletsAmpicillin in premeasured tablets.#300021
IPTG1 gram#300127

*Chloramphenicol resistant

Protein Expression / General Cloning strain selection table

CategoryApplication / FeatureStrainCatalog #Efficiency
Protein ExpressionGeneral Protein ExpressionBL21-Gold cells (≥ 1 x 108)*#200130
Protein ExpressionGeneral Protein ExpressionBL21 cells (≥ 1 x 106)*#200133
Protein ExpressionToxic ProteinsBL21-CodonPlus (DE3)-RIPL cells (≥ 1 x 106)*#230280
Protein ExpressionToxic ProteinsBL21-Gold (DE3) cells (≥ 1 x 103)*#230132
Protein ExpressionToxic ProteinsBL21 (DE3) cells (≥ 1 x 106)*#200131
Protein ExpressionToxic ProteinsBL21-CodonPlus (DE3)-RIL cells (≥ 1 x 107)*#230245
Protein ExpressionToxic ProteinsBL21-CodonPlus RIL cells (≥ 1 x 107)*#230240
Protein ExpressionWhen Even Tighter Control is RequiredBL21-Gold (DE3) pLysS cells (≥ 1 x 108)*#230134
Protein ExpressionWhen Even Tighter Control is RequiredBL21 (DE3) pLysS cells (≥ 1 x 106)*#200132
Protein ExpressionWhen Even Tighter Control is RequiredBL21-CodonPlus (DE3)-RP cells (≥ 1 x 107)*#230255
General CloningUnmethylated DNASoloPack Gold cells (≥ 1 x 109)*#200350
General CloningUnmethylated DNASoloPack Gold cells ≥ 1 x 108)*#200325
General CloningUnmethylated DNASCS110 cells (≥ 5 x 106)*#200247
General CloningendA-for improved plasmid yield and better quality miniprep DNAJM110 cells ≥ 5 x 106)*#200239
General CloningMutagenesisXL1-Red cells (≥ 1 x 106)*#200129
General CloningConvenient CloningXL1-Blue cells (≥ 1 x 108)*#200249
General CloningConvenient CloningXL1-Blue subcloning cells (≥ 1 x 106)*#200130
General CloningUnlimited DNA or SubcloningXL2-Blue cells (≥ 5 x 109)*#200150
General CloningUnlimited DNA or SubcloningXL1-Blue cells ≥ 1 x 109)*#200236
General CloningUnlimited DNA or SubcloningXL1-Blue electroporation cells (≥ 1 x 1010)*#200228
General CloningUnlimited DNA or SubcloningXL2-Blue MRF’ cells (≥ 1 x 109)*#200151
General CloningUnlimited DNA or SubcloningXL1-Blue MRF’ electroporation cells (≥ 1 x 1010)*#200158
General CloningUnlimited DNA or SubcloningXL1-Blue MR cells (≥ 1 x 109)*#200229

*efficiency = cfu/µg pUC18. Codon Bias Problems: Universal Strain, High GC Content, High AT Content. Contents: Difficult Cloning, Protein Expression, Appendix, Order Information, 17, General Cloning, Key to Genotypes, 15, Hte and Hee Phenotypes, 5, XL10-Gold Ultracompetent Cells, 6, Newly Improved Electro-Ten Blue Cells, 7, Cloning Difficult DNA, 8, Protein Expression, 10, XL1-Blue Strain, 12, Convenient Cloning, 13, Generate Unmethylated DNA, 14, Mutagenesis, 14.

Table 1. Codon usage in various organisms. Codon frequencies are expressed as codons used per 1000 codons encountered. The arginine codons AGG and AGA are recognized by the same tRNA and should therefore be combined. Codon frequencies of more than 15 codons/1000 codons are shown in bold to help identify a codon bias that may cause problems for high level expression in E. coli.

OrganismAGG arginineAGA arginineCUA leucineAUA isoleucineCCC proline
Escherichia coli1.22.13.94.45.5
Homo sapiens11.411.56.56.920.0
Drosophila melanogaster6.45.18.29.218.0
Caenorhabditis elegans4.015.48.09.74.5
Saccharomyces cerevisiae9.321.313.417.86.8
Plasmodium falciparium4.120.215.233.28.5
Clostridium pasteurianum2.429.46.250.00.9
Pyrococcus horikoshii30.120.118.244.510.2
Thermus aquaticus14.31.33.61.438.8
Arabidopsis thaliana10.918.810.012.75.3

* These frequencies are updated regularly. A complete compilation of codon usage of the sequences in the gene bank database can be found at www.kazusa.or.jp/codon/

Genotypes

Host StrainGenotype
ABLE K StrainE. coli C lac(LacZω–) [Kanr McrA– McrCB– McrF– Mrr– HsdR (rK – mK –)] [F´ proAB lacIqZΔM15 Tn10 (Tetr)]
BL21-Gold StarinE. coli B F– dcm+ Hte ompT hsdS(rB – mB –) gal endA Tetr a
BL21-Gold(DE3) StrainE. coli B F– dcm+ Hte ompT hsdS(rB – mB –) gal λ (DE3) endA Tetr a
BL21-Gold(DE3)pLysS StrainE. coli B F– dcm+ Hte ompT hsdS(rB – mB –) gal λ(DE3) [pLysS Camr]* endA Tetr a
BL21 StrainE. coli B F– dcm ompT hsdS(rB – mB –) gal
BL21(DE3) StrainE. coli B F– dcm ompT hsdS(rB – mB –) gal λ(DE3)
BL21(DE3)pLysS StrainE. coli B F– dcm ompT hsdS(rB – mB –) gal λ(DE3) [pLysS Camr]*
BL21-CodonPlus (DE3)-RIPL StrainE. coli B F– ompT hsdS(rB – mB –) dcm+ Tetr gal λ(DE3) endA Hte [argU proL Camr] [argU ileY leuW Strep/Specr]
BL21-CodonPlus RIL StrainE. coli B F– ompT hsdS(rB – mB –) dcm+ Tetr gal endA Hte [argU ileY leuW Camr]*,a
BL21-CodonPlus(DE3)-RIL StrainE. coli B F– ompT hsdS(rB – mB –) dcm+ Tetr gal λ(DE3) endA Hte [argU ileY leuW Camr]*,a
BL21-CodonPlus (DE3)-RP StrainE. coli B F– ompT hsdS(rB – mB –) dcm+ Tetr gal λ(DE3) endA Hte [argU proL Camr]*,a
ElectroTen-Blue StrainΔ(mcrA)183 (mcrB-hsdSMR-mrr)173 endA1 supE44 thi-1 recA1 gyrA96 relA1 lac Kanr Hee [F´proAB lacIqZΔM15Tn10(Tetr)]**
JM101 StrainsupE thi-1 Δ(lac-proAB) [F´ traD36 proAB lacIqZΔM15]
JM109 Straine14–(McrA–) recA1 endA1 gyrA96 thi-1 hsdR17 (rK – mK+) supE44 relA1 Δ(lac-proAB) [F´ traD36 proAB lacIqZΔM15]
JM110 StrainrpsL (Strr) thr leu thi-1 lacY galK galT ara tonA tsx dam dcm supE44 Δ(lac-proAB) [F´ traD36 proAB lacIqZΔM15]
SCS1 StrainrecA1 endA1 gyrA96 thi-1 hsdR17 (rK – mK +) supE44 relA1
SCS110 StrainrpsL (Strr) thr leu endA thi-1 lacY galK galT ara tonA tsx dam dcm supE44 Δ(lac-proAB) [F´ traD36 proAB lacIqZΔM15]
SURE Straine14–(McrA–) Δ(mcrCB-hsdSMR-mrr)171 endA1 supE44 thi-1 gyrA96 relA1 lac recB recJ sbcC umuC::Tn5 (Kanr) uvrC [F´ proAB lacIqZΔM15 Tn10 (Tetr)]
SURE 2 Straine14–(McrA–) Δ(mcrCB-hsdSMR-mrr)171 endA1 supE44 thi-1 gyrA96 relA1 lac recB recJ sbcC umuC::Tn5 (Kanr) uvrC [F´ proAB lacIqZΔM15 Tn10 (Tetr) Amy Camr]*
TG1 StrainsupE thi-1 Δ(lac-proAB) Δ(mcrB-hsdSM)5(rK – mK –) [F´ traD36 proAB lacIqZΔM15]
XL1-Blue StrainrecA1 endA1 gyrA96 thi-1 hsdR17 supE44 relA1 lac [F´ proAB lacIqZΔM15 Tn10 (Tetr)]
XL1-Blue MR StrainΔ(mcrA)183 Δ(mcrCB-hsdSMR-mrr)173 endA1 supE44 thi-1 recA1 gyrA96 relA1 lac
XL1-Blue MRF' StrainΔ(mcrA)183 Δ(mcrCB-hsdSMR-mrr)173 endA1 supE44 thi-1 recA1 gyrA96 relA1 lac [F´ proAB lacIqZΔM15 Tn10 (Tetr)]
XL2-Blue StrainrecA1 endA1 gyrA96 thi-1 hsdR17 supE44 relA1 lac [F´ proAB lacIqZΔM15 Tn10 (Tetr) Amy Camr]*
XL2-Blue MRF' StrainΔ(mcrA)183 Δ(mcrCB-hsdSMR-mrr)173 endA1 supE44 thi-1 recA1 gyrA96 relA1 lac [F´ proAB lacIqZΔM15 Tn10 (Tetr) Amy Camr]*
XL10-Gold StrainTetr Δ(mcrA)183 Δ(mcrCB-hsdSMR-mrr)173 endA1 supE44 thi-1 recA1 gyrA96 relA1 lac Hte [F´ proAB lacIqZΔM15 Tn10 (Tetr) Amy Camr]*
XL1-Red StrainendA1 gyrA96 thi-1 hsdR17 supE44 relA1 lac mutD5 mutS mutT Tn10 (Tetr)

* Chloramphenicol resistant at concentrations of < 40 µg/mL, but sensitive at concentrations of 100 µg/mL. ** The F' episome in ElectroTen-Blue cells is not functional for infection with M13 bacteriophage. a This strain, a derivative of E. coli B, is a general protein expression strain that lacks both the Lon protease and the OmpT protease, which can degrade proteins during purification. The Dcm methylase, naturally lacking in E. coli B, is inserted into the genome. ABLE, ElectroTen-Blue, BL21-CodonPlus, pBluescript, SoloPack, SURE, and XL10-Gold are registered trademarks Agilent in the United States. StrataClean is a trademark of Agilent.

Engineering Facts

14 facts · every claim linked to a page
Selection

Choose ultracompetent cells when the application requires the highest chemical transformation efficiency for plasmid library construction or large constructs.

Transformation efficiency directly determines whether rare or large constructs yield enough colonies for library representation.

Source
“Ultracompetent cells provide the highest efficiencies for chemically competent E. coli.”
Selection

Use electroporation-competent cells when cloning limited amounts of DNA or large inserts, because they provide the highest efficiency.

Electroporation efficiency is roughly two orders of magnitude higher than chemical transformation, which matters when DNA is scarce.

Source
“Ease-of-use and high efficiency make electroporation a popular method for library construction, cloning larger inserts, or cloning limited amounts of DNA.”
Selection

Select the Hte phenotype strains for large plasmids and ligated DNA, as they are engineered to improve transformation of these substrates.

Ligated and large DNA transform poorly in standard hosts; the Hte phenotype reduces this bottleneck.

Source
“These phenotypes allow you to efficiently transform large plasmid and ligated DNA.”
Selection

Use SURE cells when cloning unstable DNA containing inverted repeats or Z-DNA structures to reduce rearrangement and deletion.

Standard repair and recombination systems can delete or rearrange unstable inserts, so host genotype must be matched to insert stability.

Source
“Agilent SURE competent cells13 were designed to easily clone DNA containing these irregular structures by removing E. coli genes involved in the rearrangement and deletion of DNA.”
Selection

Use ABLE K cells to propagate toxic clones by reducing plasmid copy number ten-fold instead of recloning into a low-copy vector.

Lower copy number reduces toxic protein load and improves cell viability without changing the expression construct.

Source
“The ABLE K strain provides an easy alternative to recloning projects by reducing the copy number of plasmids by 10-fold.”
Selection

Choose restriction-minus MR series strains when cloning methylated eukaryotic DNA or cDNA to avoid cleavage by E. coli host restriction systems.

Host restriction of methylated DNA reduces library representation and cloning efficiency for eukaryotic sources.

Source
“The bacterial strains in our MR series are deficient in all known E. coli K12 restriction systems to eliminate this problem.”
Selection

Use BL21-CodonPlus strains when the gene of interest contains codons rare in E. coli, to avoid truncated or misincorporated protein.

Codon bias depletes tRNA pools and causes translation problems that cannot be fixed by culture or induction optimization alone.

Source
“BL21-CodonPlus cells dramatically improve protein expression in E. coli by overcoming the problem of codon bias.”
Selection

Choose BL21(DE3)pLysS derivatives for toxic proteins because the pLysS plasmid provides tighter control of uninduced expression.

Leaky T7 expression before induction can kill cells or select for mutations when the product is toxic.

Source
“The presence of this inhibitor prevents leaky expression in uninduced cells.”
Selection

Use the basic BL21 strain with lambda CE6 infection when the tightest possible control of expression is required for extremely toxic proteins.

T7 RNA polymerase is supplied only by infection, preventing any basal expression from the T7 promoter before induction.

Source
“Since induction cannot occur until infection, this strain provides the tightest control of protein expression for extremely toxic proteins.”
Selection

Select dam-/dcm- strains such as SCS110 or JM110 when the downstream workflow requires digestion with methylation-sensitive restriction enzymes.

DNA propagated in standard hosts is methylated and cannot be cut by enzymes such as Xba I, Cla I, or EcoR II.

Source
“We offer the SCS110 and JM110 strains, which lack both dam and dcm activity.”
Operation

Purify ligated DNA before electroporation to remove DNA ligase, which inhibits the electroporation process.

Residual ligase or salt in the ligation mix causes arcing and low transformation efficiency during electroporation.

Source
“Before electroporation, ligated DNA must be purified to remove DNA ligase, a potential inhibitor of electroporation.”
Operation

Use StrataClean resin to remove protein contamination from ligation reactions in about five minutes as an alternative to phenol extraction and ethanol precipitation.

A fast cleanup step is needed before electroporation and reduces hands-on time compared with traditional purification.

Source
“Because of its high affinity for proteins, StrataClean resin removes protein contamination with extraction complete in only five minutes.”
Performance

ElectroTen-Blue cells are specified at a minimum of 3.0 x 10^10 transformants per microgram of supercoiled pUC DNA.

This specification sets the expected yield of colonies per microgram and is used to size ligation and library experiments.

Source
“Agilent ElectroTen-Blue electroporation-competent cells offer high transformation efficiencies of ≥ 3.0 x 1010 for supercoiled pUC DNA”
Performance

XL10-Gold cells are specified at a minimum of 5 x 10^9 transformants per microgram and are intended for large plasmids and ligated DNA.

The guaranteed efficiency determines how much DNA is needed to obtain a representative library from large constructs.

Source
“XL10-Gold ultracompetent cells provide the highest chemical transformation efficiencies of large plasmids and ligated DNA.”