Technical Data

Parameter Value Condición
Rated frequency 50 Hz p.2 ↗ 2BH1 630
Rated frequency 60 Hz p.2 ↗ 2BH1 630
Rated voltage 380 V p.2 ↗ 2BH1 630, 50 Hz
Rated voltage 400 V p.2 ↗ 2BH1 630, 60 Hz
Rated current 11,8 A p.2 ↗ 2BH1 630, 50 Hz, 380 V
Rated current 14,5 A p.2 ↗ 2BH1 630, 60 Hz, 380 V
Rated motor power 5,80 kW p.2 ↗ 2BH1 630, 50 Hz
Rated motor power 7,50 kW p.2 ↗ 2BH1 630, 60 Hz
Max. differential pressure (vacuum) -150 mbar p.2 ↗ 2BH1 630, 50 Hz
Max. differential pressure (vacuum) -280 mbar p.2 ↗ 2BH1 630, 60 Hz
Max. differential pressure (pressure) 130 mbar p.2 ↗ 2BH1 630, 50 Hz
Max. differential pressure (pressure) 240 mbar p.2 ↗ 2BH1 630, 60 Hz
Sound pressure level 73/75 dB(A) p.2 ↗ 2BH1 630, 50 Hz
Sound pressure level 73/75 dB(A) p.2 ↗ 2BH1 630, 60 Hz
Weight 53 kg p.2 ↗ 2BH1 630, 50 Hz
Weight 62 kg p.2 ↗ 2BH1 630, 60 Hz
VFD rated mains voltage 380 V p.2 ↗ VFD frame A–K
VFD protection class IP55 p.2 ↗ VFD frame A–K
VFD rated motor power 1,5 kW p.2 ↗ VFD frame A
VFD rated motor power 7,5 kW p.2 ↗ VFD frame F
VFD rated motor power 22,0 kW p.2 ↗ VFD frame K
VFD weight 3,9 kg p.2 ↗ VFD frame A

Operating Limits

  • Max. suction and ambient temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Minimum VFD pulse frequency: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
  • Minimum VFD mains voltage: 380 V p.1 ↗
  • VFD protection class: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH1630 Type designation: side channel blower 2BH1, size 630
7-8 p.2 ↗ -1 Series/variant identifier
VFD 1-8 p.2 ↗ 2FC4xxx Frequency converter type designation
VFD 10-11 p.2 ↗ □□ Placeholder for voltage/frequency option code
VFD 12-13 p.2 ↗ 00 Fixed suffix

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH1630-1A326 p.2 ↗ 2BH1630-1A326 50 Hz, 380 V, 5.80 kW VFD frame E
2BH1630-1A336 p.2 ↗ 2BH1630-1A336 60 Hz, 380 V, 7.50 kW VFD frame F
2BH1630-1AK16 p.2 ↗ 2BH1630-1AK16 50/60 Hz, 400 V, 4.30/5.80 kW VFD frame D
2BH1630-1AK26 p.2 ↗ 2BH1630-1AK26 50/60 Hz, 400 V, 5.80/7.50 kW VFD frame E
2BH1630-1AK36 p.2 ↗ 2BH1630-1AK36 50/60 Hz, 400 V, 7.50 kW VFD frame F