Technical Data Sheet — L-BL2 2BL2251 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BL2 251, bomba de vacío de circuito compacta (serie L-BL2, 'Pump in a Box'), 3~ 50/60 Hz, IP55, clase de aislamiento F, UL 1450 / CAN/CSA C22.2 No. 68-09. Códigos de pedido 2BL2251-0 □ K02-1B, -6B, -3B, -7B con variantes de tensión/frecuencia y variantes de material K, B, R, H.
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Power | 4,2 kW p.2 ↗ | 2BL2251, 50 Hz, IE3 |
| Power | 5,6 kW p.2 ↗ | 2BL2251, 60 Hz, IE3 |
| Service factor | 1,31 p.2 ↗ | 2BL2251, 50 Hz |
| Service factor | 1,13 p.2 ↗ | 2BL2251, 60 Hz |
| Current | 25,4 / 12,7 A p.2 ↗ | 2BL2251, 50 Hz, 190-210 Δ / 380-420 Y |
| Current | 21,5 / 10,8 A p.2 ↗ | 2BL2251, 60 Hz, 220-240 Δ / 440-480 Y |
| Current | 19,3 A p.2 ↗ | 2BL2251, 50 Hz, 220-240 Δ |
| Current | 8,6 A p.2 ↗ | 2BL2251, 50 Hz, 500 Y |
| Current | 7,4 A p.2 ↗ | 2BL2251, 60 Hz, 575 Y |
| Current | 11,2 / 6,5 A p.2 ↗ | 2BL2251, 50 Hz, 380-420 Δ / 660-725 Y |
| Current | 11,0 A p.2 ↗ | 2BL2251, 60 Hz, 440-480 Δ |
| Current | 9,3 A p.2 ↗ | 2BL2251, 60 Hz, 460 Δ |
| Noise level | 71 dB(A) p.2 ↗ | 2BL2251, 50 Hz, IE3 |
| Noise level | 76 dB(A) p.2 ↗ | 2BL2251, 60 Hz, IE3/NP |
| Weight | 223 kg p.2 ↗ | 2BL2251, 50 Hz, IE3 (* non-cast-iron version) |
| Weight | 218 kg p.2 ↗ | 2BL2251, 60 Hz, IE3 (** non-cast-iron version) |
| Protection rating | IP55 p.2 ↗ | all variants |
| Insulation class | F p.2 ↗ | all variants |
| Power supply | 3~ 50/60 Hz p.2 ↗ | all variants |
| Suction capacity | 0-800 m³/h p.1 ↗ | 2BL2251, 50/60 Hz (performance curve range) |
| Inlet pressure | 0-200 mbar abs. p.1 ↗ | 2BL2251, 50/60 Hz (performance curve range) |
| Power consumption at pump shaft | 2,0-6,0 kW p.1 ↗ | 2BL2251, 50/60 Hz (performance curve range) |
Operating Limits
- Protection rating: IP55 p.2 ↗
- Insulation material class: F p.2 ↗
- Mains frequency: 50/60 Hz p.2 ↗
- Suction pressure for characteristic curves: 1013 mbar abs. p.1 ↗
- Intake temperature for characteristic curves: 20 °C p.1 ↗
- Curve tolerance: ± 10 % p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-7 p.2 ↗ | 2BL2251 | Model range L-BL2, size 251 |
| 8-9 p.2 ↗ | -0 | Design variant |
| 11-14 p.2 ↗ | K02-1B / K02-6B / Q02-3B / Q02-7B | Voltage/frequency variant code |
| field 1 p.2 ↗ | K | 50 Hz voltage variant: 190-210 VΔ / 380-420 VY |
| field 1 p.2 ↗ | K | 60 Hz voltage variant: 190-210 VΔ / 380-420 VY |
| field 1 p.2 ↗ | K | 60 Hz voltage variant: 200 VΔ / 200 VYY / 230 VΔ / 400 VY |
| field 1 p.2 ↗ | Q | 50 Hz voltage variant: 400 VΔ / 690 VY |
| field 1 p.2 ↗ | Q | 60 Hz voltage variant: 460 VΔ |
| field 1 p.2 ↗ | Q | 50 Hz voltage variant: 475-525 VΔ |
| field 1 p.2 ↗ | Q | 60 Hz voltage variant: 550-600 VΔ |