BFT Operation Manual

Contenido

  1. Overview pp. 7-10
    Table of contents, function description, normal operation, shutdown
  2. Overview pp. 11-20
    Foreword, introduction, safety and general information
  3. Procedure pp. 21-29
    Commissioning procedures and initial setup steps
  4. Overview pp. 30-40
    Detailed function descriptions and operating modes
  5. Procedure pp. 41-54
    Setup mode procedures and parameter configuration
  6. Procedure pp. 55-57
    Normal operation procedures and usage instructions
  7. Spec pp. 58-59
    Interfaces and software update information
  8. Procedure pp. 60-66
    Service, maintenance and troubleshooting procedures
  9. Procedure pp. 67-70
    Shutdown procedures and end-of-life handling
  10. Spec pp. 71-72
    Technical annex and temperature specifications
  11. p. 9 table, 40 rows
  12. p. 38 table, 12 rows
  13. p. 32 table, 8 rows
  14. p. 31 table, 10 rows
  15. p. 39 table, 16 rows
  16. p. 34 table, 9 rows
  17. p. 8 table, 40 rows
  18. p. 10 table, 16 rows
  19. p. 12 table, 6 rows

Содержание (оглавление) страницы 9

РазделНазваниеСтраница
4.2.6Sub-category: “Configuration manual”49
4.2.6.1Sub-category: “Change parameters”49
4.2.6.2Sub-category: “Display parameters”50
4.2.6.3Sub-category: “Control structure”50
4.2.7Sub-category: “Reset parameters”50
4.2.8Sub-category: “Display parameters”51
4.2.9Freeze protection for temperature control unit51
4.2.10Setting the setpoint thresholds51
4.2.11Setting the setpoint52
4.3Filling and draining52
4.3.1Filling and draining of bath thermostat53
4.3.1.1Filling of bath thermostat53
4.3.1.2Draining the bath thermostat54
5Normal operation55
5.1Automatic operation55
5.1.1Temperature control55
5.1.1.1Starting the temperature control process55
5.1.1.2Ending the temperature control process55
5.1.2Temperature control via a created temperature control program56
5.1.2.1Starting the temperature control program56
5.1.2.2Ending/cancelling the temperature control program56
5.1.3Temperature control via beer force ageing test program56
5.1.3.1Start beer force ageing test56
5.1.3.2Stop/cancel beer force ageing test program57
6Interfaces and software update58
6.1Interfaces at the “Pilot ONE®” controller58
6.1.110/100 Mbps Ethernet for RJ45 network sockets58
6.1.2USB-2.0 interface59
6.1.2.1USB-2.0 interface, host59
6.1.2.2USB-2.0 interface, device59
6.2Interfaces at the back59
6.2.1Service interface59
6.2.2RS232 (option) / activation of cooling bath59
6.3Firmware update59
7Service/maintenance60
7.1Messages from the temperature control unit60
7.2Electrical fuse60
7.3Replacing the “Pilot ONE®”60
7.4Maintenance61
7.4.1Function check and visual inspection61

Это оглавление, а не матрица конфигураций; транспонирование не применялось.

“X” = Value is reset, “–” = Value is not reset (A) = All together; (B) = Device parameters without OT; (C) = Device Parameter; (D) Program Controller; (E) = Menu; (F) = Com.G@te

Description(A)(B)(C)(D)(E)(F)
AcousticsXXX–––
Display functions Warnings; Messages; Inactive Menu Items; Resolution TemperatureXXX–––
Display modesXXX–––
AutoStart responseXXX–––
Limitations DeltaT limit; max. heating variable; max. cooling variable; max. permissible current consumption (for 230 V temperature control units)XXX–––
Com.G@te (only if Com.G@te is connected) Analog Interface (configuration input) Meaning of AIF input; response on cable break; measurement range settingXXX––X
Calibration–––––X
In case of analog error; current / voltage switching; filter constantXXX––X
Configuration Output AIF output variable; Output range settingXXX––X
Calibration–––––X
RS232/RS485 (Hardware RS, Baud rate, device address); ECS Standby; POKO AlarmXXX–––
Properties (other) Change thermal fluid (thermal fluid, liter indicator, bypass usage); cooling bath / cooling (CC-E only)XXX–––

“X” = Value is reset, “–” = Value is not reset. (A) = All together; (B) = Device parameters without OT; (C) = Device Parameter; (D) Program Controller; (E) = Menu; (F) = Com.G@te

Overview of the E-grade variants

Temperature control units / E-gradeE-grade BasicE-grade ExclusiveE-grade Profes-sional
Brewing thermostats–XO
Unistat temperature control units––X
UniCAL––X
Other temperature control unitsXOO
E-grade “Explore” (only for “Unistat”-series temperature control units)
The E-grade includes E-grade “Professional” functionalities. In addition it includes: – Sensor calibration for return sensor – Return temperature display – Display of performance (estimated or calculated from volume flow) – Display mode “Explore” instead of “numerically large” – PB commands correspond to DV-E-grade, except: Temperatures only in 0.01 °C and volume flows only in 0.1 l/min.––O
E-grade “DV-E-grade” – All interface commands are enabled. – Temperatures in 0.001 C, volume flows in 0.001 l/min possible (cf. E-grade Explore) Note: Only the interface commands are enabled, not the corresponding menu items in Pilot ONE!OOO
E-grade “OPC-UA” – OPC-UA interface via Ethernet. This E-grade additionally includes DV-E-grade functionalities.OOO

X = Standard equipment, O = optional, – = not possible

Thermal fluid: Water

DesignationSpecification
Calcium carbonate per liter≤ 1.5 mmol/l; corresponds to a water hardness of: ≤ 8.4 °dH (soft)
pH valuebetween 6.0 and 8.5
Ultrapure water, distillatesAdd 0.1 g of sodium carbonate (Na2CO3) per liter
Non-approved waterDistilled, deionized, demineralized, chloric, ferruginous, ammoniacal, contaminated or untreated river water or sea water
Thermal fluid: Water without ethylene glycol
Operation without freeze protection≥ +5 °C
Operation with freeze protection< +5 °C
Thermal fluid: Water-ethylene glycol mixture
Use< 0 °C
Thermal fluid compositionThe mixture’s temperature must be 10 K below the permissible min. temperature. For the permissible temperature range, refer to the datasheet. → From page 71, section »Annex«.

Description

Description(A)(B)(C)(D)(E)(F)
Sensor calibration––––––
Automated compressorXXX–––
Enter programX––X––
Pump settings Pump speed setpoint; Pump pressure setpoint; Control ModeXXX–––
Fluid properties Thermal fluid; liter indicatorXXX–––
Configuration manual parameters
Protective function High Limit Alarm Internal; Low Limit Alarm Internal; High Limit Alarm Process; Low Limit Alarm Process; Hydrostatic Correction; Warning Time Limit (CC-E only); Min. Level (for temperature control units with analogue level sensor); Max. Level (for temperature controllers with analogue level sensor); Freeze Protection (optional)XXX–––
SetpointXXX–––
Setpoint limitation Min. Setpoint; Max. SetpointXXX–––
LanguageXXX–––
Temperature formatXXX–––
Temperature control modeXXX–––
Favourites menuX–––X–
Pilot ONE Ethernet IP address; Subnet Mask; Remote AccessXXX–––
Time formatXXX–––
2. SetpointXXX–––

Строка «Configuration manual parameters» напечатана без значений в колонках (A)–(F).

Function description

FunctionE-grade BasicE-grade ExclusiveE-grade Professional
Remote control / data visualization via Spy softwareXXX
E-grade evaluation versions available (valid for 30 days)XXX
Storage/loading temperature control programs onto USB stick–XX
Copying settings––X
Service data recorders (flight recorder)XXX
PB commands1XXX
Communication Watchdog––X
Process data recording directly to a USB stick: Setpoint, Actual Value Internal and Actual Value Process / Heating Capacity %, Cooling Capacity %, and Pump Pressure / Pump Speed, and VPC Pressure–/–/–X/X/–X/X/X
Calendar start––X

1 See Data Communication Manual. Anything controllable via the graphical user interface of the Pilot ONE can be controlled by PB commands.

Содержание (оглавление)

РазделНазваниеСтраница
2.10.2Connection via hard wiring29
3Function description30
3.1Function description of the temperature control unit30
3.1.1General functions30
3.1.2Other functions30
3.2Information on the thermal fluids30
3.3To be noted when planning the test31
3.4“Pilot ONE®” controller32
3.4.1Functional overview of “Pilot ONE®”32
3.5Clock/event function34
3.5.1Rechargeable accumulator34
3.5.2Programmable event function34
3.5.2.1Event function “Alarm clock event”34
3.5.2.2Event function “Program event”34
3.6Operation via the touch screen34
3.7Display instruments35
3.7.1The touchscreen [88]35
3.8Control instruments35
3.8.1The touchbuttons36
3.8.2The categories36
3.8.3The sub-categories36
3.8.4The dialogs36
3.9Function examples36
3.9.1Display of software version36
3.9.2Start & Stop37
3.9.3Copying the settings to a data carrier37
3.9.3.1Saving to a USB flash drive37
3.9.3.2Loading from a USB flash drive38
3.9.4Restore factory settings38
3.9.4.1Restore to factory settings without overtemperature protection39
3.9.4.2Restore to factory settings including overtemperature protection39
4Setup mode41
4.1Setup mode41
4.1.1Turning on the temperature control unit41
4.1.2Turning off the temperature control unit41
4.1.3Setting the overtemperature protection42
4.1.3.1General information on the overtemperature protection42
4.1.3.2Setting “OT limit: heating”42
4.1.3.3Setting “Process Safety”43
4.1.3.4Monitoring via “Display OT values”43

Это оглавление, а не матрица конфигураций; транспонирование не применялось.

8 Shutting down

РазделНазваниеСтраница
8Shutting down67
8.1Safety instructions and basic principles67
8.2Switch-off68
8.3Draining the temperature control unit68
8.4Draining the cooling water68
8.4.1Draining process68
8.5Uninstalling an external application69
8.6Packing69
8.7Shipping69
8.8Disposal70
8.9Contact data70
8.9.1Telephone number: Customer Support70
8.9.2Telephone number: Sales70
8.9.3Email address: Customer Support70
8.10Certificate of Compliance70
9Annex71

Identification / symbol

Identification / symbolDescription
→Reference to information / procedure.
»TEXT«Reference to a chapter in the operation manual. In the digital version, the text is clickable.
>TEXT< [NUMBER]Reference to the wiring diagram in the annex. The designation and the search digit are specified.
>TEXT< [LETTER]Reference to a drawing in the same paragraph. The designation and the search digit are specified.
▪List, first level
‒List, second level

Engineering Facts

14 facts · every claim linked to a page
Safety

The unit must not be installed or started in an ATEX zone; explosion protection requires an Ex px cabinet.

Determines whether the unit can be placed in a hazardous area at all.

Source
“Do NOT install or start up the temperature control unit within an ATEX zone.”
Installation

A drip tray for condensation water/thermal fluid must be installed below the unit by the responsible body.

Affects floor preparation and containment design at the installation site.

Source
“The responsible body must install a condensation water / thermal fluid drip tray below the temperature control unit.”
Cumplimiento

For natural refrigerants, the max charge per room volume is 8 g/m³ and units over 1 kg must not be installed below ground level.

Constrains room size, ventilation and installation elevation for NR units.

Source
“Temperature control units with more than 1 kg refrigerant must not be installed below ground level (GL).”
Safety

If natural refrigerant charge exceeds 8 g/m³ room air, a calibrated gas warning sensor must be fitted and maintained every 6–12 months.

Adds a mandatory gas detection and calibration regime to the installation.

Source
“Over 8 g refrigerant per m³ room air: A gas warning sensor must be fitted and functioning.”
Installation

The unit must be transported and stored upright only; horizontal transport damages the compressor.

Dictates rigging and shipping orientation to avoid compressor damage.

Source
“Only transport the temperature control unit in an upright position.”
Installation

Casters are only for positioning, not transport, and require at least 2 persons (5 persons above 1.5 t).

Sets manpower and handling requirements for placing the unit.

Source
“At least 5 persons are required to move the temperature control unit on the casters if the total weight of the temperature control unit is over 1.5 tons.”
Installation

After a cold-to-warm move the unit must acclimate about 2 hours before power-on.

Prevents condensation-related electrical damage during commissioning.

Source
“Allow the temperature control unit to acclimate for about 2 hours when changing from a cold to a warm environment (or vice versa).”
Installation

Leveling feet must be unscrewed/activated and casters braked before switching on, then lock screws tightened.

Ensures stability and prevents the unit from moving during operation.

Source
“Always unscrew/activate the leveling feet before switching on the temperature control unit.”
Operation

When using the bath, place the sample in the empty bath first, then fill; removing the sample can trigger low-level shutdown.

Avoids false low-level safety trips during bath thermostat operation.

Source
“Place your sample into the empty bath. Only then fill in a sufficient amount of temperature control medium.”
Performance

Thermal fluid viscosity must not exceed 50 mm²/s at the lowest working temperature and density must not exceed 1 kg/dm³.

Limits fluid selection and achievable pump performance at low temperature.

Source
“The maximum viscosity of the thermal fluid must not exceed 50 mm²/s at the lowest working temperature!”
Operation

Water used as thermal fluid must have hardness ≤ 8.4 °dH and pH between 6.0 and 8.5; distilled/deionized water is not approved.

Defines water quality for filling to avoid corrosion and scaling.

Source
“between 6.0 and 8.5”
Operation

Different thermal fluid types must never be mixed; the circuit must be rinsed when changing fluid type.

Prevents fluid degradation and material damage during changeover.

Source
“Do not mix different types of thermofluid (such as mineral oil, silicone oil, synthetic oil, water, etc.) in a thermofluid circuit.”
Operation

After a power failure the restart behavior is selectable (Standby, ON, Power Failure Auto) via Pilot ONE.

Determines unattended restart behavior and process safety after outages.

Source
“If temperature control is active during a power outage, the process will automatically continue after the power outage.”
Maintenance

The air filter mat behind the supply air connection must be checked/replaced regularly to keep airflow unobstructed.

Adds a recurring maintenance item affecting cooling performance.

Source
“This air filter mat must be checked / replaced at regular intervals so that the air flowing into the temperature control unit is not reduced.”