Agilent Bond Elut Lipid Extraction
Technical Reference Summary
Covered Models & Document Scope
Placa de 96 pocillos Agilent Bond Elut Lipid Extraction, 1 placa, número de referencia 5610-2042; guía de método para precipitación de proteínas, carga de muestra, lavado y elución de lípidos
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Plate format | 96-well plate p.1 ↗ | |
| Sorbent chemistry | EMR—Lipid p.1 ↗ | |
| Recommended crashing solvent | ACN with 5% MeOH p.1 ↗ | |
| Crashing solvent to sample ratio | 9:1 p.1 ↗ | |
| Washing solvent | ACN with 10 to 20% water p.1 ↗ | |
| Elution solvent | MeOH with DCM, chloroform, or 1-chlorobutane p.1 ↗ | |
| Minimum MeOH content for elution | 50 % p.1 ↗ | |
| Recommended elution solvent | DCM/MeOH (v/v 1:2) or chloroform/MeOH (v/v 1:1) p.1 ↗ | |
| Plasma sample volume | 100 μL p.2 ↗ | |
| Collection plate volume | 2 mL p.2 ↗ | |
| Crashing solvent volume | 900 μL p.2 ↗ | |
| Sonicating time | 10 minutes p.2 ↗ | on ice |
| Wash solvent volume | 2 × 1 mL p.2 ↗ | ACN/water (v/v 9:1) |
| Elution volume | 1 mL p.2 ↗ | DCM/MeOH (v/v 1:2) |
Operating Limits
- For Research Use Only; not for use in diagnostic procedures: p.2 ↗
Ordering Data
| Ordering Code | Part No. | Variant / Code | Aplica a | Note |
|---|---|---|---|---|
| Agilent Bond Elut Lipid Extraction, 96-well plate p.2 ↗ | 5610-2042 | 1 plate |