Cary UV-Vis-NIR Spectrophotometers

Sommaire

  1. Overview pp. 1-2
    Introduces the Cary UV-Vis-NIR spectrophotometer family
  2. Config. p. 3
    Application-specific configurations and accessory options table
  3. Spec p. 4
    Quality and performance design principles
  4. Overview pp. 5-6
    Plug-and-go lamp and optical performance details
  5. Spec p. 7
    Advanced NIR performance for photonics applications
  6. Overview p. 8
    Versatility of Cary instruments across applications
  7. Services p. 9
    Support and leadership in spectroscopy
  8. p. 10
    Solar cell and photovoltaic measurement applications
  9. p. 11
    Nanocomposite and optical component applications
  10. p. 12
    Thin film characterization applications
  11. p. 13
    Optical filter measurement applications
  12. p. 14
    Biotechnology and pharmaceutical applications
  13. Overview p. 15
    Cary software capabilities and features
  14. Services p. 16
    Agilent CrossLab service and support offerings
  15. p. 3 table, 9 rows

Common applications for the Cary 4000/5000/6000i and Common sampling techniques supported by the Cary 4000/5000/6000i

AcademiaMaterials Testing & ResearchChem & PetrochemEnergy & FuelsFood & AgricultureBiotech & Pharma
Common applications for the Cary 4000/5000/6000i
Thin film thickness analysis and anti-reflection coating analysisAnalysis of novel nanocomposite materialsColour measurements and colour matchingOptical density measurements, e.g. optical filters and safety eye wearSpectro-electrochemical measurements, for e.g. reduction of CO2Measuring suspensions and highly scattering samples
Analysis of heavy metals in waterQuantitative analysis of strongly absorbing liquid media or suspensionsAnalysis of the functionality of photoresistsMeasurement of oil yield in oil shale samplesAnalysis of the reflectance properties of solar cellsStudy of paints and effect of pigments in the automotive Industry
Assessment of crop condition, such as chlorophyll, water and dry matter contentQuantitative analysis of additivesQC applicationsMeasurement of turbid biological samplesCharacterization of intracellular biochemical pathwaysAnalysis of potential sun blocking agents for sun cream and cosmetics
Common sampling techniques supported by the Cary 4000/5000/6000i
Variable/fixed angle specular reflectance accessoryDouble beam absolute specular reflectance accessoryDiffuse reflectance accessory (internal and external)Praying mantis reflectance accessoryBrewster angle holderSample transport with film holder
Rear beam attenuatorFibre optic accessorySolid sample holderPolarizer/depolarizer attachmentRear beam attenuatorRapid mix accessory
Fiber optic microprobe (liquids)Thermostatted single and multicell holders with temperature probesMicrovolume cuvettesRapid mix accessoryWater thermostatted 6x6 multicell holder accessorySingle cell peltier accessory (accurate temperature control)
Cell holder for standard and specialized cellsSingle cell peltier accessory (accurate temperature control)Diffuse reflectance accessory (internal and external)Water thermostatted 6x6 multicell holder accessoryRapid mix accessory

Engineering Facts

12 facts · every claim linked to a page
Selection

The Cary 4000 covers 175–900 nm, so it is the right choice only when measurements stay within UV-Vis.

Wavelength range is the first selection criterion; choosing the 4000 for NIR work would be a mismatch.

Source
“Cary 4000 (175–900 nm)”
Selection

The Cary 5000 extends to 3300 nm and needs only one detector for NIR, simplifying the optical configuration.

Fewer detectors means fewer changeover mechanisms and a simpler, more reliable NIR setup.

Source
“It requires only one detector to extend that performance into the NIR.”
Selection

The Cary 6000i is optimized for 1200–1800 nm with an InGaAs detector, so it is the pick for shortwave NIR resolution work.

If the application needs fine NIR bands near 1200–1800 nm, only this model meets the requirement.

Source
“optimized for the shortwave NIR, delivering superior resolution in the 1200–1800 nm region.”
Performance

Signal-to-noise mode lets the user set a precision target across the scan and cuts scan time by more than half.

Affects throughput planning and method design for samples with strongly varying absorbance.

Source
“S:N mode reduces scanning times by over 50% as the system scans quickly in areas of high energy throughput”
Installation

The monochromator and sample compartments can be purged separately, allowing a higher purge rate in the sample compartment.

Matters when installing gas purging for NIR or hygroscopic-sample work.

Source
“allowing the sample compartment to be purged at a higher rate than the instrument.”
Performance

With reference beam attenuation the instruments can typically measure absorbance beyond eight.

Determines whether dilution steps can be avoided for strongly absorbing samples.

Source
“the instruments can typically measure absorbances beyond eight.”
Installation

The LockDown mechanism fixes accessories reproducibly in the sample compartment without tools or alignment procedures.

Reduces setup time and variability when swapping accessories during installation or method changes.

Source
“eliminate tools and time- consuming alignment procedures.”
Maintenance

Lamps are pre-aligned and easy to replace, and the electronics accept a wide range of lamp designs.

Shortens downtime and simplifies spare-part planning for lamp replacement.

Source
“Lamps are pre-aligned and easy to replace.”
Maintenance

Silica overcoated optics allow cleaning without damaging the reflective surface.

Affects cleaning procedures and long-term optical reliability in dusty or humid labs.

Source
“Protects optics from the environment and allows cleaning without damage to the reflective surface.”
Installation

The sample compartment has a removable floor plate for flexible mounting of large or odd-shaped samples.

Needed when planning mounting of uncut glass, wafers or large accessories.

Source
“Includes removable floor plate for maximum flexibility when mounting samples.”
Operation

The VASRA scans the angle of incidence automatically under PC control while translating the sample so the same region is measured at every angle.

Enables reproducible reflectance-versus-angle measurements for coating and thin-film work.

Source
“the angle of incidence is automatically and accurately scanned under full PC control.”
Conformité

Complete IQ/OQ qualification services are offered for hardware, software and accessories.

Required for regulated labs needing documented installation and operational qualification.

Source
“Agilent offers complete qualification services (IQ/OQ) for the Cary 4000/5000/6000i Series UV-Vis-NIR hardware, software and accessories.”