Introduces the Cary 60 UV-Vis and its key benefits
Overviewp. 3
Highlights application areas and flexibility
Qualityp. 4
Describes design quality and performance features
Specp. 5
Details proven optical performance and reliability
Overviewp. 6
Explains sustainable lab practices and energy efficiency
Overviewp. 7
Shows broad application capabilities of the Cary
Overviewp. 8
Describes Cary WinUV software features and usability
Overviewp. 9
QA/QC applications in chemicals and energy sectors
Overviewp. 10
Teaching and research applications in academia
Overviewp. 11
Applications in biotechnology and pharmaceutical industries
Procedurep. 12
Rapid and precise kinetics measurement capabilities
Servicesp. 13
Agilent CrossLab service and support offerings
p. 4table, 4 rows
p. 3table, 10 rows
With a Cary 60 UV-Vis powered by a xenon flash lamp, here's what your lab could save:
After 1 year
After 10 years
Cost savings
$4,500
$45,000
Time savings
200 hrs
2,000 hrs
Lamp replacements per year
Weeks of downtime per lamp replacement
Assumes a deuterium and tungsten lamp replacement cost of $1,400 per set, a requalification cost of $3,100 per lamp set change, a 30-minute daily warm-up time, and 240 working days per year. All amounts are in U.S. dollars. Choose a value based on your lab operational model: 1, 2
Common applications and accessories for the Agilent Cary 60 UV-Vis
Chemicals & Energy
Academic
Biotech & Pharma
Quality control of raw materials and finished goods
Study of pigments in art conservation through reflectance measurements
DNA and protein quantification
Color measurements and color matching
Characterization of unknown or newly synthesized compounds
Measuring cold biological samples (4 °C) immediately after removal from the refrigerator
Analysis of nutrients in water, food, and agriculture
Monitoring kinetics of chemical or biological reactions that occur at sub-second rate
Drug purity and API concentration
Analysis of turbid solutions or relatively highly absorbing samples
Measurement of films and optical components
Preparation of fluorescent liquid samples before emission measurements
Analysis of bulk optics (e.g., sunglasses)
Analyzing photochemical reactions in situ during sample irradiation
Analyzing small amounts of precious sample (<4 µL)
Fiber optic transmission and reflectance probes and coupler
Fiber optic transmission and reflectance probes and coupler
Fiber optic microprobe (liquids)
Thermostatted single and multicell holders with temperature probes
Thermostatted single and multicell holders with temperature probes
Thermostatted single and multicell holders with temperature probes
18 cell changer
Solid sample holder
Microvolume cuvettes
Rectangular, cylindrical, micro, and flow cells
Rectangular, cylindrical, micro, and flow cells
TrayCell 2.0 Ultra-Microvolume Cell
Rapid mix accessory
Верхние строки — Common applications for the Agilent Cary 60 UV-Vis; нижние строки — Common accessories for the Agilent Cary 60 UV-Vis.
Engineering Facts
14 facts · every claim linked to a page
Selection
The xenon flash lamp has an exceptionally long lifetime of 3 billion flashes and comes with a 10-year warranty, which lowers cost of ownership.
Long lamp life and warranty reduce replacement and maintenance costs when selecting the instrument.
Source
“with an exceptionally long lifetime of 3 billion flashes, the lamp comes with a 10-year warranty”
Operation
The instrument can scan the entire 190 to 1,100 nm range in under 3 seconds at up to 24,000 nm/min.
Fast scanning enables high-throughput measurements and rapid kinetics data collection.
Source
“with a scan rate of up to 24,000 nm/min, you can scan the entire wavelength range (190 to 1,100 nm) in under 3 seconds”
Operation
The focused beam allows accurate and reproducible measurement of sample volumes below 4 µL.
Microvolume capability is essential when sample quantity is limited or precious.
Source
“Preserve your samples by using less than 4 µL instead of mLs.”
Operation
The optical design is immune to room light, so measurements can be made with the sample compartment open.
Allows measurement of large or odd-shaped samples without a closed compartment and reduces user error.
Source
“the unique optical design enables measurements to be made with the sample compartment open”
Performance
The photometric range extends above 3.5 absorbance units with a correlation coefficient of 0.999 on certified standards.
High linear absorbance range supports accurate analysis of concentrated or highly absorbing samples.
Source
“The photometric range of the Cary 60 UV-Vis extends above 3.5 absorbance units.”
Operation
The xenon lamp only flashes when a reading is taken, eliminating photodegradation of light-sensitive samples.
Protects precious or photosensitive samples from excessive UV exposure and heat.
Source
“The lamp only flashes when a reading is taken eliminating photo degradation”
Performance
The focused light beam is less than 1.5 mm × 1.0 mm at its focus, ensuring excellent noise performance even with small aperture microcells.
Small beam size improves signal-to-noise when using microvolume cells.
Source
“less than 1.5 mm × 1.0 mm at its focus—ensuring excellent noise performance even when using small aperture microcells”
Operation
The double beam design provides simultaneous sample and reference beam measurements, maintaining peak integrity at every scan speed.
Double beam configuration improves accuracy and stability during fast scans.
Source
“As a double beam UV-Vis instrument the Cary 60 UV-Vis maintains peak integrity at every scan speed through simultaneous sample and reference beam measurements.”
Maintenance
The xenon source lamp requires no warmup time and only flashes when a reading is taken, reducing energy consumption.
Eliminates warmup delays and lowers electrical energy use in the lab.
Source
“xenon source lamp only flashes when a reading is taken, no warmup time”
Selection
A wide range of accessories supports liquid, solid, powder, and paste samples, including thermostatted holders and fiber-optic probes.
Accessory compatibility determines whether the instrument can handle diverse sample types and automation needs.
Source
“The vast range of accessories for the Cary 60 UV-Vis ensures you can handle the widest variety of sample sizes and types.”
Conformité
Optional built-in technical controls support compliance with US FDA 21 CFR Part 11, EU Annex 11, and similar electronic record regulations.
Regulated laboratories require data integrity controls for electronic records.
Source
“Optional built-in technical controls ensure the security of your data, control access, and facilitate compliance as defined by US FDA 21 CFR Part 11, EU Annex 11 and similar national electronic record regulations.”
Operation
The Kinetics software can collect data for up to 5 days without limiting the number of data points collected.
Supports long, slow reactions and extended kinetic studies.
Source
“can collect data for up to 5 days without limiting the number of data points collected”
Operation
The rapid mix accessory automatically starts analysis in less than 1/10th of a second after mixing two components.
Enables stopped-flow kinetics measurements of short-lived reactions.
Source
“the rapid mix accessory enables you to automatically start an analysis in less than 1/10th of a second after the two components are mixed”
Operation
The fiber optic microprobe can measure cold samples directly from the refrigerator without condensation problems.
Allows direct measurement of cold biological samples without cuvette condensation issues.
Source
“As the microprobe is completely submerged in the sample there are no condensation problems”