Induztr
Résumé technique Visionneuse de documents Modèles associés

Agilent Streptavidin, Phycobiliprotein and Conjugate Products

Sommaire

  1. Overview pp. 1-2
    Introduction to Agilent streptavidin and partnering information
  2. Config. p. 3
    Streptavidin product variants and selection table
  3. Spec p. 4
    Immobilized streptavidin formats and specifications
  4. Overview p. 5
    Native-source fluorescent proteins from continuous culture
  5. Config. p. 6
    Phycobiliprotein product options and characteristics
  6. Spec p. 7
    Activated phycobiliprotein variants and specifications
  7. Spec p. 8
    Phycobiliprotein conjugate products and properties
  8. Spec pp. 9-10
    Streptavidin-RPE conjugate specifications and ordering
  9. Spec p. 11
    Streptavidin-APC conjugate specifications and ordering
  10. Services p. 12
    Agilent CrossLab support and service information
  11. p. 10 table, 20 rows
  12. p. 3 table, 5 rows
  13. p. 4 table, 10 rows
  14. p. 6 table, 16 rows
  15. p. 7 table, 6 rows
  16. p. 9 table, 3 rows
  17. p. 11 table, 5 rows

Streptavidin-RPE conjugates

Product DescriptionPart NumberPack SizeApplicationConjugate Size
Streptavidin-R-PhycoerythrinPJ31S-11 mgPJ31S is a conjugate specifically manufactured for optimum performance in bead-based assays such as the Luminex platform. Superceded by newer conjugates PJRS20 and PJRS301.Large
PJ31S-55 mg
PJ31S50 mg
Streptavidin-R-Phycoerythrin (ver 2)PJ39S-11 mgA conjugate that is predominantly a single peak on an HPLC/SEC chromatogram, consistent with approximately two streptavidin molecules conjugated to a single R-phycoerythrin molecule. Potential applications include single molecule detection systems and quantitative analysis in flow cytometry.Small
PJ39S50 mg
Streptavidin-R-Phycoerythrin (ver 4)PJRS20-11 mgPJRS20 is manufactured for optimum performance in bead-based assays.Large
PJRS20-1010 mg
PJRS2050 mg
Streptavidin-R-Phycoerythrin (ver 5)PJRS25-11 mgPJRS25 is one of several unique Streptavidin-RPE conjugates that has shown to improve performance of some bead-based assays such as the Luminex platform.Med
PJRS25-1010 mg
PJRS2550 mg
Streptavidin-R-Phycoerythrin (ver 6)PJRS27-11 mgPJRS27 is manufactured for optimum performance in tetramer and multimer applications1 as well as flow cytometry and bead-based assays such as the Luminex platform.Med
PJRS27-1010 mg
PJRS2750 mg
Streptavidin-R-Phycoerythrin (ver 7)PJRS301-11 mgPJRS301 is our newest streptavidin-RPE conjugate and is specifically manufactured for optimum performance in bead-based assays. PJRS301 manufacture includes additional steps designed to ensure consistent lot performance over time.Large
PJRS301-1010 mg
PJRS-30150 mg
Streptavidin-R-Phycoerythrin (ver 9)PJRS34-11 mgPJRS34 is manufactured as a low background conjugate for research applications utilizing bead-based assays.Large
PJRS34-1010 mg
PJRS3450 mg

1. NIH Tetramer Core Facility. [Internet]. Atlanta, GA: Emory University; c2006-2010. Class I MHC Tetramer Preparation: Overview; [cited 2020 Oct 21]. Available from: http://tetramer.yerkes.emory.edu/support/protocols

Streptavidin Products

Product DescriptionPart NumberPack size*Tetramer SizeSpecific Activity**Applications
Streptavidin Native from Streptomyces avidinii ('core' streptavidin)SA10-1010 mg~52 kDa≥ 14.0 U/mgConjugation, ELISA
SA10-100100 mg
SA101000 mg
Streptavidin-plus Recombinant gene from Streptomyces avidinii expressed in E. coliSA26-1010 mg~55 kDa≥ 15.0 U/mgConjugation, ELISA, performs well in applications where streptavidin is immobilized
SA26-100100 mg

* These streptavidin products are available in various pack sizes and are supplied lyophilized. Large quantities are available from single lots, with exceptional lot-to-lot consistency. ** Specific activity is measured by the industry-standard HABA dye-binding assay. The specific activity measurement is higher still when measured by the alternative biotin-titration assay used by some suppliers.

Product Description

Product DescriptionPart NumberPack Size
Streptavidin-AgaroseCJ30R-1010 mL
CJ30R-2020 mL
CJ30R100 mL
Streptavidin-HRP conjugate ELISA Optimized for applications that require high signal-to-noise ratios. Made with improved non-mercury stabilizer.CJ30H-33 x 1 mL
CJ30H-1010 mL
CJ30H-100100 mL
HRP conjugate stabilizer For dilution (up to 1,000-fold) of HRP conjugates (50% with deionized water). Contains a mercury-free azide-free preservative.CJ95500 mL
CJ95-10001000 mL
AP conjugate stabilizer For dilution (up to 1,000-fold) of AP conjugates (50% with deionized water). Contains a mercury-free azide-free preservativeCJ90500 mL
CJ90-10001000 mL

Phycobiliprotein options

Product DescriptionPart NumberPack Size*ApplicationsAbsorbance Maximum (nm)Fluorescence emission (nm)Molecular Weight (kDa)
R-Phycoerythrin (RPE+) Isolated from a species of red algae chosen specifically because it yields one of the most highly fluorescent of the RPEs.PB32-1010 mgFluorescent immunolabeling, flow cytometry, Luminex or other bead-based applications.566 (496 secondary)575240
PB32-100100 mg
PB32500 mg
Allophycocyanin (Spirulina sp) Isolated from Spirulina sp., a blue-green alga, APC has extremely high absorptivity and a high quantum efficiency. Can be easily linked to antibodies and other proteins.PB20-1010 mgFluorescent immunolabeling, particularly in applications involving fluorescent-activated cell sorting (FACS) or time-resolved fluorescence resonance transfer (TR-FRET).648 - 652~660104
PB20-100100 mg
PB20500 mg
Cross-linked Allophycocyanin Cross-linking APC creates the most stable form available as the crosslinked αβ subunits provide increased structural integrity in the presence of chaotropic salts. There are one or two crosslinks created per APC molecule.PB25-1010 mgFluorescent immunolabeling, particularly in applications involving FACS or TR-FRET.64–652~660104
PB25-5050 mg
PB25-100100 mg
PB25500 mg
C-Phycocyanin (Spirulina sp) Isolated from Spirulina sp., a blue-green alga. Like other phycobiliproteins, CPC is fluorescent, with an extremely high absorptivity and a high quantum efficiency.PB1110 mgUsed in a variety of immunological assays and as fluorescent labels for cell-sorting. Because of the high molar absorbtivity of CPC and other phycobiliproteins at visible wavelength, they are convenient markers in such applications as gel electrophoresis, isoelectric focusing and gel exclusion chromatography.620647232
PB11-500500 mg
PerCP (Dinophyceae sp) Peridinin-chlorophyll-protein complex (PerCP) is isolated from Dinophyceae sp.PB40-1010 mgFluorescent immunolabeling, particularly in applications involving FACS.48267735.5
PB40-5050 mg
PB40-100100 mg
PB40500 mg

* These phycobiliprotein products are available in various pack sizes. Large quantities are available from single lots, with exceptional lot-to-lot consistency. Please contact us if you are interested in a sample to test.

Activated Phycobiliproteins / RPE Conjugation Kit

Product DescriptionPart NumberPack Size*ApplicationAbsorbance Maximum (nm)Fluorescence emission (nm)Molecular Weight (kDa)
Activated R-Phycoerythrin RPE activated with SMCC then goes through a buffer exchange step and filtered using a 0.45 µm membrane.PJRC10-55 mgConjugation of antibodies and other proteins.566 (496 secondary)575240
Activated R-Phycoerythrin RPE activated with SMCC then goes through a buffer exchange step and filtered using a 0.45 µm membrane.PJRC10100 mgConjugation of antibodies and other proteins.566 (496 secondary)575240
Activated Allophycocyanin APC crosslinked and then activated with SMCC. After a buffer exchange step, the product is filtered using a 0.45 µm membrane.PJ25C-55 mgConjugation of APC antibodies and other proteins.648–652~660104
Activated Allophycocyanin APC crosslinked and then activated with SMCC. After a buffer exchange step, the product is filtered using a 0.45 µm membrane.PJ25C-1010 mgConjugation of APC antibodies and other proteins.648–652~660104
Activated Allophycocyanin APC crosslinked and then activated with SMCC. After a buffer exchange step, the product is filtered using a 0.45 µm membrane.PJ25C100 mgConjugation of APC antibodies and other proteins.648–652~660104
R-Phycoerythrin Conjugation Kit Contains everything you need to conjugate up to 1 mg of your antibody to RPE, including 3.2 mg activated RPE.PJ31K1 kitConjugation of RPE to antibodies or other proteins. Reaction may be scaled up by utilizing additional activated RPE (p/n PJRC10).566 (496 secondary)575240

* These phycobiliprotein products are available in various pack sizes. Large quantities are available from single lots, with exceptional lot-to-lot consistency. Please contact us if you are interested in a sample to test.

Streptavidin-RPE conjugate selection guide

Part NumberConjugate SizeApplication
PJRS301*; PJRS20; PJRS34LargeLuminex and other bead-based assays
PJRS25**; PJRS27MediumTetramer
PJ39SSmallFlow cytometry

* PJRS301 is our newest conjugate, developed for long-term signal consistency. **PJRS25 is used in the NIH (Emory) Tetramer Core Facility protocol1, along with our streptavidin-APC conjugate PJ27S.

Table

Product DescriptionPart NumberPack SizeApplication
Streptavidin-AllophycocyaninPJ25S0.25 mgPJ25S is a larger conjugate than PJ27S, and is better suited for FRET assays.
PJ25S-11 mg
PJ25S-1010 mg
Streptavidin-Allophycocyanin (ver 2)PJ27S0.25 mgPJ27S is specifically designed for use in tetramer and multimer applications1.
PJ27S-11 mg

1 — сноска в тексте ячейки Application (PJ27S).

Engineering Facts

13 facts · every claim linked to a page
Selection

Choose native SA10 for general conjugation/ELISA work, but recombinant SA26 when streptavidin will be immobilized as an ELISA capture agent.

Immobilization format drives which streptavidin variant to order.

Source
“Streptavidin-plus has been found to have superior performance in certain applications, such as when immobilized as an ELISA capture agent.”
Operation

Lyophilized streptavidin dissolves readily in water or salt buffers up to 50 mg/mL or more, so reconstitution is straightforward.

Defines reconstitution buffer and maximum working concentration.

Source
“Agilent streptavidin is supplied lyophilized and is readily soluble in water or salt-containing buffers, at concentrations of up to 50 mg/mL or more.”
Operation

Streptavidin-Agarose beads are stable across pH 4–11, so buffers outside this range must be avoided.

Sets the allowable pH window for chromatography/affinity purification buffers.

Source
“The linkage is stable through a wide pH range (4–11).”
Selection

Streptavidin-Agarose uses 4.3% cross-linked agarose with 75–300 micron beads and >1 mg/mL streptavidin, informing column packing and capacity planning.

Bead size and ligand density determine flow properties and binding capacity.

Source
“Streptavidin-Agarose is streptavidin attached to beads of cross-linked 4.3% agarose with a bead size distribution of 75–300 microns.”
Operation

The streptavidin-HRP conjugate uses a non-mercury stabilizer, avoiding mercury-based preservative handling.

Affects storage/handling and compatibility with sensitive assays.

Source
“The conjugate is made with an improved non-mercury stabilizer ensuring long-term stability.”
Operation

HRP and AP conjugate stabilizers are diluted up to 1,000-fold, 50% with deionized water, and are mercury- and azide-free.

Defines dilution protocol and preservative compatibility for conjugate storage.

Source
“For dilution (up to 1,000-fold) of HRP conjugates (50% with deionized water). Contains a mercury-free azide-free preservative.”
Selection

Cross-linked APC should be selected when chaotropic salts are present, since crosslinking provides structural integrity.

Buffer composition (chaotropes) dictates whether standard or cross-linked APC is required.

Source
“Cross-linking APC creates the most stable form available as the crosslinked αβ subunits provide increased structural integrity in the presence of chaotropic salts.”
Operation

Activated phycobiliproteins are SMCC-treated and react with free sulfhydryl groups, so targets must carry free thiols and need no added crosslinker.

Determines target protein preparation (free sulfhydryls) and eliminates crosslinker addition step.

Source
“They are ready to use and will conjugate without further preparation upon mixing with sulfhydryl-containing targets.”
Operation

The RPE conjugation kit conjugates up to 1 mg antibody, scales down to 50 µg, and conjugates can be ready in as little as two hours.

Sets scale range and time budget for in-house conjugation.

Source
“Complete step-by-step protocols are included and allow small scale conjugations down to 50 µg of antibody.”
Selection

Conjugate size must match the assay: large SA-RPE for bead-based assays, medium for tetramer, small for flow cytometry.

Prevents choosing a conjugate optimized for the wrong assay platform.

Source
“the optimal conjugates for bead-based assays are not usually the same as the optimal conjugates for MHC tetramer assays”
Selection

PJ39S is predominantly a single HPLC/SEC peak with about two streptavidin per RPE, suited to single-molecule and quantitative flow cytometry.

Homogeneity matters for quantitative and single-molecule detection systems.

Source
“A conjugate that is predominantly a single peak on an HPLC/SEC chromatogram, consistent with approximately two streptavidin molecules conjugated to a single R-phycoerythrin molecule.”
Selection

PJ25S is a larger SA-APC conjugate better suited for FRET, while PJ27S is designed for tetramer/multimer work.

FRET versus tetramer applications require different APC conjugate sizes.

Source
“PJ25S is a larger conjugate than PJ27S, and is better suited for FRET assays.”
Operation

APC is normally used internally cross-linked because it is stable at the low concentrations required for most uses.

Low-concentration working conditions require the cross-linked APC form.

Source
“APC is usually used in an internally crosslinked form which is stable at the low concentrations required for most uses.”