Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — 2BH1600 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 600: sopladores de canal lateral con motores IE3, tamaños 1-4, 50 Hz y 60 Hz, diversos rangos de tensión (190-210 V, 220-240 V, 380-420 V, 440-480 V, 475-525 V, 550-600 V, 200 V, 230 V, 400 V, 460 V, 690 V) y variantes de motor (IE3, NP). Códigos de pedido 2BH1600-0AK01, -0AK11, -0AK21, -1AK31, -0AK06, -0AK16, -0AK26, -1AK36, -0AQ03, -0AQ13, -0AQ23, -1AQ33, -0AQ07, -0AQ17, -0AQ27, -1AQ37, -0AQ06, -0AQ16, -0AQ26, -1AQ36.

Technical Data

Parameter Value Condition
Rated voltage 190-210 V p.2 ↗ 2BH1600-0AK01, size 1, 50 Hz, Δ
Rated current 6,9 A p.2 ↗ 2BH1600-0AK01, size 1, 50 Hz, Δ
Rated power 1,75 kW p.2 ↗ 2BH1600-0AK01, size 1, 50 Hz
Vacuum -130 mbar p.2 ↗ 2BH1600-0AK01, size 1, 50 Hz
Pressure 120 mbar p.2 ↗ 2BH1600-0AK01, size 1, 50 Hz
Sound level 69 dB(A) p.2 ↗ 2BH1600-0AK01, size 1, 50 Hz
Efficiency class IE3 p.2 ↗ 2BH1600-0AK01, size 1, 50 Hz
Weight 31 kg p.2 ↗ 2BH1600-0AK01, size 1, 50 Hz
Rated voltage 190-210 ΥΥ / 380-420 Υ V p.2 ↗ 2BH1600-0AK01, size 1, 60 Hz
Rated current 7,8 ΥΥ / 3,9 Υ A p.2 ↗ 2BH1600-0AK01, size 1, 60 Hz
Rated power 2,00 kW p.2 ↗ 2BH1600-0AK01, size 1, 60 Hz
Vacuum -110 mbar p.2 ↗ 2BH1600-0AK01, size 1, 60 Hz
Pressure 110 mbar p.2 ↗ 2BH1600-0AK01, size 1, 60 Hz
Sound level 72 dB(A) p.2 ↗ 2BH1600-0AK01, size 1, 60 Hz
Efficiency class IE3 p.2 ↗ 2BH1600-0AK01, size 1, 60 Hz
Weight 31 kg p.2 ↗ 2BH1600-0AK01, size 1, 60 Hz
Rated voltage 190-210 V p.2 ↗ 2BH1600-0AK11, size 2, 50 Hz, Δ
Rated current Δ A p.2 ↗ 2BH1600-0AK11, size 2, 50 Hz, Δ
Rated power 2,50 kW p.2 ↗ 2BH1600-0AK11, size 2, 50 Hz
Vacuum -200 mbar p.2 ↗ 2BH1600-0AK11, size 2, 50 Hz
Pressure 190 mbar p.2 ↗ 2BH1600-0AK11, size 2, 50 Hz
Sound level 64 dB(A) p.2 ↗ 2BH1600-0AK11, size 2, 50 Hz
Efficiency class IE3 p.2 ↗ 2BH1600-0AK11, size 2, 50 Hz
Weight 34 kg p.2 ↗ 2BH1600-0AK11, size 2, 50 Hz
Rated voltage 190-210 ΥΥ / 380-420 Υ V p.2 ↗ 2BH1600-0AK11, size 2, 60 Hz

Operating Limits

  • Max ambient temperature for performance curves: 25 °C p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature: 15 °C p.1 ↗
  • Reference atmospheric pressure: 1013 mbar p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH1600 Type/size designation (2BH1 600)

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH1600-0AK01 p.2 ↗ 2BH1600-0AK01 size 1, 50/60 Hz, 190-210 V Δ / 190-210 V ΥΥ / 380-420 V Υ IE3, 1.75 kW (50 Hz), 2.00 kW (60 Hz)
2BH1600-0AK11 p.2 ↗ 2BH1600-0AK11 size 2, 50/60 Hz, 190-210 V Δ / 190-210 V ΥΥ / 380-420 V Υ IE3, 2.50 kW (50 Hz), 3.00 kW (60 Hz)
2BH1600-0AK21 p.2 ↗ 2BH1600-0AK21 size 3, 50/60 Hz, 190-210 V Δ / 190-210 V ΥΥ / 380-420 V Υ IE3, 3.45 kW (50 Hz), 4.0 kW (60 Hz)
2BH1600-1AK31 p.2 ↗ 2BH1600-1AK31 size 4, 50/60 Hz, 190-210 V Δ / 380-420 V Υ IE3, 4.6 kW (50 Hz), 5.3 kW (60 Hz)
2BH1600-0AK06 p.2 ↗ 2BH1600-0AK06 size 1, 50/60 Hz, 220-240 V Δ / 380-420 V Υ IE3, 1.75 kW (50 Hz), 2.00 kW (60 Hz)
2BH1600-0AK16 p.2 ↗ 2BH1600-0AK16 size 2, 50/60 Hz, 220-240 V Δ / 380-420 V Υ IE3, 2.50 kW (50 Hz), 3.00 kW (60 Hz)
2BH1600-0AK26 p.2 ↗ 2BH1600-0AK26 size 3, 50/60 Hz, 220-240 V Δ / 380-420 V Υ IE3, 3.45 kW (50 Hz), 4.0 kW (60 Hz)
2BH1600-1AK36 p.2 ↗ 2BH1600-1AK36 size 4, 50/60 Hz, 220-240 V Δ / 380-420 V Υ IE3, 4.6 kW (50 Hz), 5.3 kW (60 Hz)
2BH1600-0AQ03 p.2 ↗ 2BH1600-0AQ03 size 1, 50/60 Hz, 475-525 V Υ / 550-600 V Υ IE3, 1.75 kW (50 Hz), 2.00 kW (60 Hz)
2BH1600-0AQ13 p.2 ↗ 2BH1600-0AQ13 size 2, 50/60 Hz, 475-525 V Υ / 550-600 V Υ IE3, 2.50 kW (50 Hz), 3.00 kW (60 Hz)

Modèles liés