Hoja de datos 2BH1 810-1: soplador de canal lateral con motores IE3, tamaños 1/2/3 (2BH1810-1HK21/HK31/HK41, HK26/HK36/HK46, HQ27/HQ37/HQ47, HQ26/HQ36/HQ46), 50 Hz y 60 Hz, diversas variantes de tensión (K, Q, motor de tensión alternativa), clases de eficiencia IE3 y NP

Technical Data

Parameter Value Condition
Rated frequency 50 Hz p.2 ↗ 2BH1810-1HK21, size 1
Voltage 190-210 V p.2 ↗ 2BH1810-1HK21, 50 Hz, delta
Current 30,8 A p.2 ↗ 2BH1810-1HK21, 50 Hz, delta
Power 8,6 kW p.2 ↗ 2BH1810-1HK21, 50 Hz
Vacuum -460 mbar p.2 ↗ 2BH1810-1HK21, 50 Hz
Pressure 420 mbar p.2 ↗ 2BH1810-1HK21, 50 Hz
Sound level 74 dB(A) p.2 ↗ 2BH1810-1HK21, 50 Hz
Efficiency class IE3 p.2 ↗ 2BH1810-1HK21, 50 Hz
Weight 188 kg p.2 ↗ 2BH1810-1HK21
Power 9,9 kW p.2 ↗ 2BH1810-1HK21, 60 Hz
Vacuum -420 mbar p.2 ↗ 2BH1810-1HK21, 60 Hz
Pressure 350 mbar p.2 ↗ 2BH1810-1HK21, 60 Hz
Sound level 78 dB(A) p.2 ↗ 2BH1810-1HK21, 60 Hz
Power 12,6 kW p.2 ↗ 2BH1810-1HK31, 50 Hz
Vacuum -460 mbar p.2 ↗ 2BH1810-1HK31, 50 Hz
Pressure 670 mbar p.2 ↗ 2BH1810-1HK31, 50 Hz
Weight 203 kg p.2 ↗ 2BH1810-1HK31
Power 17,3 kW p.2 ↗ 2BH1810-1HK41, 50 Hz
Vacuum -460 mbar p.2 ↗ 2BH1810-1HK41, 50 Hz
Pressure 670 mbar p.2 ↗ 2BH1810-1HK41, 50 Hz
Weight 212 kg p.2 ↗ 2BH1810-1HK41
Protection category IP 55 p.1 ↗ standard motors
Insulation class F p.1 ↗ standard motors

Operating Limits

  • Max suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature for performance curves: 15 °C p.1 ↗
  • Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗

Type Code Decoder

Position Token Meaning
1-5 p.2 ↗ 2BH1 Side channel blower series
6-9 p.1 ↗ 810-1 Size / data sheet designation