Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — 2BH1910 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 910: soplador de canal lateral con motores IE3, tamaños 1-4, 50 Hz y 60 Hz, diversas variantes de tensión (190-210 V Δ, 220-240 V Δ / 380-420 V Y, 475-525 V Y, 380-420 V Δ / 660-725 V Y), variantes de motor IE3 y NP

Technical Data

Parameter Value Condition
Suction capacity 240 m³/h p.2 ↗ 2BH1910, size 1, 50 Hz
Suction capacity 360 m³/h p.2 ↗ 2BH1910, size 2, 50 Hz
Suction capacity 480 m³/h p.2 ↗ 2BH1910, size 3, 50 Hz
Suction capacity 590 m³/h p.2 ↗ 2BH1910, size 4, 50 Hz
Suction capacity 190 m³/h p.2 ↗ 2BH1910, size 1, 60 Hz
Suction capacity 300 m³/h p.2 ↗ 2BH1910, size 2, 60 Hz
Suction capacity 410 m³/h p.2 ↗ 2BH1910, size 3, 60 Hz
Suction capacity 540 m³/h p.2 ↗ 2BH1910, size 4, 60 Hz
Total pressure difference -270 mbar p.2 ↗ 2BH1910, size 1, 50 Hz
Total pressure difference -410 mbar p.2 ↗ 2BH1910, size 2, 50 Hz
Total pressure difference -440 mbar p.2 ↗ 2BH1910, size 3, 50 Hz
Total pressure difference -440 mbar p.2 ↗ 2BH1910, size 4, 50 Hz
Total pressure difference -220 mbar p.2 ↗ 2BH1910, size 1, 60 Hz
Total pressure difference -360 mbar p.2 ↗ 2BH1910, size 2, 60 Hz
Total pressure difference -440 mbar p.2 ↗ 2BH1910, size 3, 60 Hz
Total pressure difference -450 mbar p.2 ↗ 2BH1910, size 4, 60 Hz
Power consumption at pump shaft 12.6 kW p.2 ↗ 2BH1910, size 1, 50 Hz
Power consumption at pump shaft 17.3 kW p.2 ↗ 2BH1910, size 2, 50 Hz
Power consumption at pump shaft 21.3 kW p.2 ↗ 2BH1910, size 3, 50 Hz
Power consumption at pump shaft 25.3 kW p.2 ↗ 2BH1910, size 4, 50 Hz
Sound pressure level 72 dB(A) p.2 ↗ 2BH1910, size 1-4, 50 Hz
Sound pressure level 76 dB(A) p.2 ↗ 2BH1910, size 1-4, 60 Hz
Weight 295 kg p.2 ↗ 2BH1910, size 1
Weight 303 kg p.2 ↗ 2BH1910, size 2
Weight 317 kg p.2 ↗ 2BH1910, size 3

Operating Limits

  • Max ambient temperature for total pressure differences: 25 °C p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Voltage tolerance for three phase motors: +/-10% p.2 ↗
  • Frequency tolerance: +/- 2 % maximum p.2 ↗
  • Max converter input voltage for standard motor insulation: 500 V p.2 ↗

Type Code Decoder

Position Token Meaning
1-5 p.2 ↗ 2BH19 Series and size (2BH1 = side channel blower series, 9 = size 910)
6-7 p.2 ↗ 10 Size designation (910)
10-11 p.2 ↗ HK / HQ Voltage / frequency variant: HK = 50/60 Hz wide range, HQ = 60 Hz / special voltage