Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — G-BH2 2BH20360-3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH2 0360-3: soplador de canal lateral con convertidor de frecuencia integrado (VFD), 3~ 400 V -15% … 480 V +10%, 50/60 Hz ±6%, IP55, UL 1450; variantes con devanados de motor 380 V Y / 400 V Δ y tipos de VFD A–K; opción de pedido G17 (ventilador accionado por separado), Z = U56 (interfaz EtherCAT).

Technical Data

Parameter Value Condition
Rated frequency 85 Hz p.2 ↗ 2BH2 0360-3, 380 V Y, VFD type G
Voltage 380 V p.2 ↗ 2BH2 0360-3, Y connection
Current 27.4 A p.2 ↗ 2BH2 0360-3, 380 V Y, 85 Hz
Power 14.0 kW p.2 ↗ 2BH2 0360-3, 380 V Y, 85 Hz
Max. differential pressure vacuum -570 mbar p.2 ↗ 2BH2 0360-3, 380 V Y, 85 Hz
Max. differential pressure pressure 350 mbar p.2 ↗ 2BH2 0360-3, 380 V Y, 85 Hz
Sound pressure level 76/78 dB(A) p.2 ↗ 2BH2 0360-3, 380 V Y, 85 Hz (50 Hz / 60 Hz with G17)
Weight 130 kg p.2 ↗ 2BH2 0360-3, 380 V Y, VFD type G
Weight 132 kg p.2 ↗ 2BH2 0360-3, 380 V Y, VFD type G, with separately driven fan G17
Current 41.0 A p.2 ↗ 2BH2 0360-3, 380 V Y, 85 Hz, VFD type K
Power 20.5 kW p.2 ↗ 2BH2 0360-3, 380 V Y, 85 Hz, VFD type K
Max. differential pressure pressure 790 mbar p.2 ↗ 2BH2 0360-3, 380 V Y, 85 Hz, VFD type K
Sound pressure level 77/79 dB(A) p.2 ↗ 2BH2 0360-3, 380 V Y, 85 Hz, VFD type K
Weight 173 kg p.2 ↗ 2BH2 0360-3, 380 V Y, VFD type K
Weight 175 kg p.2 ↗ 2BH2 0360-3, 380 V Y, VFD type K, with separately driven fan G17
Current 20.4 A p.2 ↗ 2BH2 0360-3, 400 V Δ, 85 Hz
Power 10.2 kW p.2 ↗ 2BH2 0360-3, 400 V Δ, 85 Hz
Max. differential pressure vacuum -250 mbar p.2 ↗ 2BH2 0360-3, 400 V Δ, 85 Hz
Max. differential pressure pressure 100 mbar p.2 ↗ 2BH2 0360-3, 400 V Δ, 85 Hz
Sound pressure level 84 dB(A) p.2 ↗ 2BH2 0360-3, 400 V Δ, 85 Hz
Current 26.0 A p.2 ↗ 2BH2 0360-3, 400 V, 85 Hz
Power 14.0 kW p.2 ↗ 2BH2 0360-3, 400 V, 85 Hz
Max. differential pressure vacuum -570 mbar p.2 ↗ 2BH2 0360-3, 400 V, 85 Hz
Max. differential pressure pressure 350 mbar p.2 ↗ 2BH2 0360-3, 400 V, 85 Hz
Current 39.5 A p.2 ↗ 2BH2 0360-3, 400 V Δ, 85 Hz, VFD type J

Operating Limits

  • Max. ambient / suction temperature for performance data: 25 °C p.1 ↗
  • Rated voltage / frequency set point: 345 V / 87 Hz p.1 ↗
  • Minimum mains voltage for frequency converter: 380 V p.1 ↗
  • Frequency converter mains voltage range: 400 V -15% … 480 V +10% p.2 ↗
  • Frequency tolerance: ±6% p.2 ↗
  • Protection class: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-8 p.2 ↗ 2BH20360 Type designation: side channel blower 2BH2, size 0360
9-10 p.2 ↗ -3 Version / stage code
11-12 p.2 ↗ AA Motor / winding variant code
16-17 p.2 ↗ -BA Design / equipment variant
VFD type field p.2 ↗ A–K Integrated frequency converter type (A 2FC4152-1 … K 2FC4223-1)

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH20360-3AA3N6-BA p.2 ↗ 2BH20360-3AA3N6-BA G 380 V Y, 85 Hz, 14.0 kW, VFD type G Weight 130 kg (132 kg with G17)
2BH20360-3AA3P6-BA p.2 ↗ 2BH20360-3AA3P6-BA K 380 V Y, 85 Hz, 20.5 kW, VFD type K Weight 173 kg (175 kg with G17)
2FC4152-1 p.2 ↗ 2FC4152-1 A VFD type A Rated mains 4 A, max. motor current 2 A, 3 kW, typical motor current 10 A, fuse 4 A, 2 kg
2FC4752-1 p.2 ↗ 2FC4752-1 F VFD type F Rated mains 18 A, max. motor current 8 A, 15 kW, typical motor current 25 A
2FC4113-1 p.2 ↗ 2FC4113-1 G VFD type G Rated mains 28 A, max. motor current 11 A, 23 kW, typical motor current 35 A
2FC4153-1 p.2 ↗ 2FC4153-1 H VFD type H Rated mains 34 A, max. motor current 15 A, 28 kW, typical motor current 50 A