Technical Data Sheet — G-BH7 2BH7520 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Ficha técnica 2BH7 520: soplador de canal lateral con convertidor de frecuencia integrado (VFD), tipo 2BH7 520. Abarca el funcionamiento con VFD a 100 Hz (400 V, delta) tamaños 1-3 (n.os de pedido 2BH7520-0A321-1, -0A351-1, -0A371-1), las variantes de conexión directa a la red de 50/60 Hz (2BH7520-0AK26-1, -0AK56-1, -0AK76-1) y los tipos de VFD correspondientes A-K (2FC4...-1□□00).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated frequency | 100 Hz p.2 ↗ | 2BH7520-0A321-1, VFD operation |
| Rated voltage | 400 V p.2 ↗ | 2BH7520-0A321-1, VFD operation |
| Rated motor current | 9,8 A p.2 ↗ | 2BH7520-0A321-1, VFD operation |
| Rated motor power | 5,0 kW p.2 ↗ | 2BH7520-0A321-1, VFD operation |
| Max. differential pressure, vacuum | -320 mbar p.2 ↗ | 2BH7520-0A321-1, VFD operation |
| Max. differential pressure, pressure | 240 mbar p.2 ↗ | 2BH7520-0A321-1, VFD operation |
| Sound pressure level | 77 dB(A) p.2 ↗ | 2BH7520-0A321-1, VFD operation |
| Weight | 57 kg p.2 ↗ | 2BH7520-0A321-1, VFD operation |
| Rated motor current | 12,7 A p.2 ↗ | 2BH7520-0A351-1, VFD operation |
| Rated motor power | 6,6 kW p.2 ↗ | 2BH7520-0A351-1, VFD operation |
| Max. differential pressure, vacuum | -520 mbar p.2 ↗ | 2BH7520-0A351-1, VFD operation |
| Max. differential pressure, pressure | 480 mbar p.2 ↗ | 2BH7520-0A351-1, VFD operation |
| Sound pressure level | 81 dB(A) p.2 ↗ | 2BH7520-0A351-1, VFD operation |
| Rated motor current | 16,2 A p.2 ↗ | 2BH7520-0A371-1, VFD operation |
| Rated motor power | 8,8 kW p.2 ↗ | 2BH7520-0A371-1, VFD operation |
| Max. differential pressure, vacuum | -560 mbar p.2 ↗ | 2BH7520-0A371-1, VFD operation |
| Max. differential pressure, pressure | 750 mbar p.2 ↗ | 2BH7520-0A371-1, VFD operation |
| Sound pressure level | 81 dB(A) p.2 ↗ | 2BH7520-0A371-1, VFD operation |
| Weight | 71 kg p.2 ↗ | 2BH7520-0A371-1, VFD operation |
| Rated voltage | 345 V p.2 ↗ | 2BH7520-0AK26-1, 87 Hz, delta |
| Rated motor current | 8,7 A p.2 ↗ | 2BH7520-0AK26-1, 87 Hz, delta |
| Rated motor power | 4,3 kW p.2 ↗ | 2BH7520-0AK26-1, 87 Hz, delta |
| Max. differential pressure, vacuum | -480 mbar p.2 ↗ | 2BH7520-0AK26-1, 87 Hz, delta |
| Max. differential pressure, pressure | 380 mbar p.2 ↗ | 2BH7520-0AK26-1, 87 Hz, delta |
| Sound pressure level | 77 dB(A) p.2 ↗ | 2BH7520-0AK26-1, 87 Hz, delta |
Operating Limits
- Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
- Min. mains voltage for frequency converter: 380 V p.1 ↗
- Min. pulse frequency of frequency converter: 4 kHz p.1 ↗
- Protection class: IP55 p.2 ↗
- Insulation material class: F p.2 ↗
- Performance curve tolerance: ± 10 % p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-7 p.2 ↗ | 2BH7520 | Type / size designation (side channel blower 2BH7, size 520) |
| field 1 p.2 ↗ | 0A / 0AK | Motor / drive variant: 0A = VFD operation (100 Hz), 0AK = 50/60 Hz direct-on-line |
| field 2 p.2 ↗ | 3 / 5 / 7 | Size stage 1 / 2 / 3 (power and pressure class) |
| field 3 p.2 ↗ | 2 / 5 / 6 | Motor power variant within size stage |
| field 4 p.2 ↗ | 1 | Design / generation index |
| VFD type letter p.2 ↗ | A … K | Frequency converter type 2FC4...-1□□00 matched to blower size |
Ordering Data
| Ordering Code | Part No. | Variant / Code | S'applique à | Note |
|---|---|---|---|---|
| 2BH7520-0A321-1 p.2 ↗ | 2BH7520-0A321-1 | E | 100 Hz, 400 V, VFD operation | VFD type E |
| 2BH7520-0A351-1 p.2 ↗ | 2BH7520-0A351-1 | E | 100 Hz, 400 V, VFD operation | VFD type E |
| 2BH7520-0A371-1 p.2 ↗ | 2BH7520-0A371-1 | F | 100 Hz, 400 V, VFD operation | VFD type F |
| 2BH7520-0AK26-1 p.2 ↗ | 2BH7520-0AK26-1 | D | 87 Hz, 345 V delta | 50/60 Hz direct-on-line variant, footnote 3 |
| 2BH7520-0AK56-1 p.2 ↗ | 2BH7520-0AK56-1 | E | 87 Hz, 400 V delta | 50/60 Hz direct-on-line variant, footnote 3 |
| 2BH7520-0AK76-1 p.2 ↗ | 2BH7520-0AK76-1 | F | 87 Hz, 400 V delta | 50/60 Hz direct-on-line variant, footnote 3 |
| 2FC4402-1 p.2 ↗ | 2FC4402-1 | D | VFD type D | 9,5 A, 4,0 kW |