Parameter Value Condition
Rated voltage 190-210 D V p.2 ↗ 2BH7620-0NK21-2, size 1, 50 Hz
Rated current 13,3 D A p.2 ↗ 2BH7620-0NK21-2, size 1, 50 Hz
Power 3,5 kW p.2 ↗ 2BH7620-0NK21-2, size 1, 50 Hz
Max. differential pressure vacuum -520 mbar p.2 ↗ 2BH7620-0NK21-2, size 1, 50 Hz
Max. differential pressure pressure 460 mbar p.2 ↗ 2BH7620-0NK21-2, size 1, 50 Hz
Sound pressure level 68 dB(A) p.2 ↗ 2BH7620-0NK21-2, size 1, 50 Hz
Weight 62 kg p.2 ↗ 2BH7620-0NK21-2, size 1, 50 Hz
Efficiency class IE3 p.2 ↗ 2BH7620-0NK21-2, size 1, 50 Hz
Rated voltage 190-210 UU / 380-420 U V p.2 ↗ 2BH7620-0NK21-2, size 1, 60 Hz
Rated current 15,2 UU / 7,6 U A p.2 ↗ 2BH7620-0NK21-2, size 1, 60 Hz
Power 4,0 kW p.2 ↗ 2BH7620-0NK21-2, size 1, 60 Hz
Max. differential pressure vacuum -470 mbar p.2 ↗ 2BH7620-0NK21-2, size 1, 60 Hz
Max. differential pressure pressure 390 mbar p.2 ↗ 2BH7620-0NK21-2, size 1, 60 Hz
Sound pressure level 72 dB(A) p.2 ↗ 2BH7620-0NK21-2, size 1, 60 Hz
Rated voltage 190-210 D V p.2 ↗ 2BH7620-0NK41-2, size 2, 50 Hz
Rated current 17,1 D A p.2 ↗ 2BH7620-0NK41-2, size 2, 50 Hz
Power 4,6 kW p.2 ↗ 2BH7620-0NK41-2, size 2, 50 Hz
Max. differential pressure vacuum -630 mbar p.2 ↗ 2BH7620-0NK41-2, size 2, 50 Hz
Max. differential pressure pressure 640 mbar p.2 ↗ 2BH7620-0NK41-2, size 2, 50 Hz
Sound pressure level 66 dB(A) p.2 ↗ 2BH7620-0NK41-2, size 2, 50 Hz
Weight 66 kg p.2 ↗ 2BH7620-0NK41-2, size 2, 50 Hz
Rated voltage 190-210 D V p.2 ↗ 2BH7620-0NK71-2, size 3, 50 Hz
Rated current 23,5 D A p.2 ↗ 2BH7620-0NK71-2, size 3, 50 Hz
Power 6,3 kW p.2 ↗ 2BH7620-0NK71-2, size 3, 50 Hz
Max. differential pressure vacuum -630 mbar p.2 ↗ 2BH7620-0NK71-2, size 3, 50 Hz

Operating Limits

  • Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature for performance curves: 15 °C p.1 ↗
  • Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH7 Series / type: side channel blower
5-7 p.2 ↗ 620 Size designation
8-9 p.2 ↗ 0N Variant / generation code
13-14 p.2 ↗ -2 Motor variant suffix
field 3 p.3 ↗ □ Alternate voltage motor code: K1, K6, or blank for standard

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH7620-0NK21-2 p.2 ↗ 2BH7620-0NK21-2 size 1, 190-210 V, 50/60 Hz, IE3 Standard voltage variant K
2BH7620-0NK41-2 p.2 ↗ 2BH7620-0NK41-2 size 2, 190-210 V, 50/60 Hz, IE3 Standard voltage variant K
2BH7620-0NK71-2 p.2 ↗ 2BH7620-0NK71-2 size 3, 190-210 V, 50/60 Hz, IE3 Standard voltage variant K
2BH7620-0NK26-2 p.2 ↗ 2BH7620-0NK26-2 size 1, 220-240 V / 380-420 V, 50/60 Hz, IE3 Voltage variant K, option 6
2BH7620-0NK46-2 p.2 ↗ 2BH7620-0NK46-2 size 2, 220-240 V / 380-420 V, 50/60 Hz, IE3 Voltage variant K, option 6
2BH7620-0NK76-2 p.2 ↗ 2BH7620-0NK76-2 size 3, 220-240 V / 380-420 V, 50/60 Hz, IE3 Voltage variant K, option 6
2BH7620-0NQ23-2 p.2 ↗ 2BH7620-0NQ23-2 size 1, 500 V / 575 V, 50/60 Hz, IE3/NP Voltage variant Q
2BH7620-0NQ43-2 p.2 ↗ 2BH7620-0NQ43-2 size 2, 500 V / 575 V, 50/60 Hz, IE3/NP Voltage variant Q
2BH7620-0NQ73-2 p.2 ↗ 2BH7620-0NQ73-2 size 3, 500 V / 575 V, 50/60 Hz, IE3/NP Voltage variant Q
2BH7620-0NQ27-2 p.2 ↗ 2BH7620-0NQ27-2 size 1, 380-420 V / 660-725 V, 50/60 Hz, IE3 Voltage variant Q, option 7