Technical Data Sheet — 2BH9230 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Ficha técnica 2BH9 2300 soplador de canal lateral con motores IE3, 3~ 50/60 Hz, IP55, clase de aislamiento F, aprobado UL/CSA; cubre variantes con diferentes códigos de tensión (K1, K6, Q3, Q5, Q7) y clase de rendimiento 1/2.

Technical Data

Parameter Value Condition
Rated frequency 50 Hz p.2 ↗ 2BH9 2300, 50 Hz
Voltage 190-210 V p.2 ↗ 2BH9 2300, 50 Hz, delta
Current 76,8 A p.2 ↗ 2BH9 2300, 50 Hz, delta
Power 21,3 kW p.2 ↗ 2BH9 2300, 50 Hz
Vacuum -210 mbar p.2 ↗ 2BH9 2300, 50 Hz
Pressure 210 mbar p.2 ↗ 2BH9 2300, 50 Hz
Noise level 81 dB(A) p.2 ↗ 2BH9 2300, 50 Hz
Efficiency class IE3 p.2 ↗ 2BH9 2300, 50 Hz
Weight 158 kg p.2 ↗ 2BH9 2300, 50 Hz
Rated frequency 60 Hz p.2 ↗ 2BH9 2300, 60 Hz
Voltage 190-210 / 380-420 V p.2 ↗ 2BH9 2300, 60 Hz, delta/delta
Current 87,4 / 43,7 A p.2 ↗ 2BH9 2300, 60 Hz, delta/delta
Power 24,5 kW p.2 ↗ 2BH9 2300, 60 Hz
Vacuum -160 mbar p.2 ↗ 2BH9 2300, 60 Hz
Pressure 150 mbar p.2 ↗ 2BH9 2300, 60 Hz
Noise level 81 dB(A) p.2 ↗ 2BH9 2300, 60 Hz
Efficiency class IE3 p.2 ↗ 2BH9 2300, 60 Hz
Weight 158 kg p.2 ↗ 2BH9 2300, 60 Hz
Protection category IP55 p.2 ↗ 2BH9 2300
Insulation class F p.2 ↗ 2BH9 2300

Operating Limits

  • Max ambient/suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Protection category: IP55 p.1 ↗
  • Insulation class: F p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH92300 Type and size designation (2BH9 series, size 2300)
field 1 p.2 ↗ K Voltage variant code K
field 2 p.2 ↗ 1 Voltage variant number 1
field 1 p.2 ↗ K Voltage variant code K
field 2 p.2 ↗ 6 Voltage variant number 6
field 1 p.2 ↗ Q Voltage variant code Q
field 2 p.2 ↗ 3 Voltage variant number 3
field 1 p.2 ↗ Q Voltage variant code Q
field 2 p.2 ↗ 5 Voltage variant number 5
field 1 p.2 ↗ Q Voltage variant code Q
field 2 p.2 ↗ 7 Voltage variant number 7

Ordering Data

Ordering Code Part No. Variant / Code S'applique à Note
2BH92300-1AAKQ1-BA p.2 ↗ 2BH92300-1AAKQ1-BA K1 50/60 Hz, 190-210 V delta / 380-420 V Y
2BH92300-1AAKR1-BA p.2 ↗ 2BH92300-1AAKR1-BA K1 50/60 Hz, 190-210 V delta / 380-420 V Y
2BH92300-1AAKQ6-BA p.2 ↗ 2BH92300-1AAKQ6-BA K6 50/60 Hz, 220-240 V delta / 440-480 V Y
2BH92300-1AAKR6-BA p.2 ↗ 2BH92300-1AAKR6-BA K6 50/60 Hz, 220-240 V delta / 440-480 V Y
2BH92300-1AAQQ7-BA p.2 ↗ 2BH92300-1AAQQ7-BA Q7 50/60 Hz, 380-420 V delta / 660-725 V Y